<
From version < 77.76 >
edited by Xiaoling
on 2022/06/10 09:24
To version < 77.67 >
edited by Xiaoling
on 2022/06/10 09:20
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -607,7 +607,6 @@
607 607  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
608 608  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
609 609  
610 -
611 611  **AT Command to set Trigger Condition**:
612 612  
613 613  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -659,17 +659,14 @@
659 659  
660 660   Yy4 yy4: AC2 or AV2 high limit.
661 661  
662 -
663 663  **Example1**: AA 00 13 88 00 00 00 00 00 00
664 664  
665 665  Same as AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
666 666  
667 -
668 668  **Example2**: AA 02 01 00
669 669  
670 670  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
671 671  
672 -
673 673  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
674 674  
675 675  MOD6 Payload : total 11 bytes payload
... ... @@ -676,7 +676,6 @@
676 676  
677 677  [[image:image-20220524085923-1.png]]
678 678  
679 -
680 680  (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below
681 681  
682 682  [[image:image-20220524090106-2.png]]
... ... @@ -683,7 +683,6 @@
683 683  
684 684  * Each bits shows if the corresponding trigger has been configured.
685 685  
686 -
687 687  **Example:**
688 688  
689 689  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -695,7 +695,6 @@
695 695  
696 696  * Each bits shows which status has been trigger on this uplink.
697 697  
698 -
699 699  **Example:**
700 700  
701 701  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -707,7 +707,6 @@
707 707  
708 708  * Each bits shows which status has been trigger on this uplink.
709 709  
710 -
711 711  **Example:**
712 712  
713 713  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -746,9 +746,8 @@
746 746  * (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
747 747  
748 748  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
741 +*
749 749  
750 -
751 -
752 752  === 3.4.1 Common Commands ===
753 753  
754 754  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -1115,7 +1115,7 @@
1115 1115  
1116 1116  
1117 1117  
1118 -==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1109 +=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
1119 1119  
1120 1120  * AT Command:
1121 1121  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0