... ... @@ -607,7 +607,6 @@
607 607  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
608 608  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
609 609  
610 -
611 611  **AT Command to set Trigger Condition**:
612 612  
613 613  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -659,17 +659,14 @@
659 659  
660 660   Yy4 yy4: AC2 or AV2 high limit.
661 661  
662 -
663 663  **Example1**: AA 00 13 88 00 00 00 00 00 00
664 664  
665 665  Same as AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
666 666  
667 -
668 668  **Example2**: AA 02 01 00
669 669  
670 670  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
671 671  
672 -
673 673  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
674 674  
675 675  MOD6 Payload : total 11 bytes payload
... ... @@ -676,7 +676,6 @@
676 676  
677 677  [[image:image-20220524085923-1.png]]
678 678  
679 -
680 680  (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below
681 681  
682 682  [[image:image-20220524090106-2.png]]
... ... @@ -683,7 +683,6 @@
683 683  
684 684  * Each bits shows if the corresponding trigger has been configured.
685 685  
686 -
687 687  **Example:**
688 688  
689 689  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -695,7 +695,6 @@
695 695  
696 696  * Each bits shows which status has been trigger on this uplink.
697 697  
698 -
699 699  **Example:**
700 700  
701 701  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -707,7 +707,6 @@
707 707  
708 708  * Each bits shows which status has been trigger on this uplink.
709 709  
710 -
711 711  **Example:**
712 712  
713 713  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -747,8 +747,6 @@
747 747  
748 748  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
749 749  
750 -
751 -
752 752  === 3.4.1 Common Commands ===
753 753  
754 754  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -770,7 +770,6 @@
770 770  
771 771  **Example: **AT+TDC=30000. Means set interval to 30 seconds
772 772  
773 -
774 774  * Downlink Payload (prefix 0x01):
775 775  
776 776  (% class="box infomessage" %)
... ... @@ -793,7 +793,6 @@
793 793  
794 794  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
795 795  
796 -
797 797  * Downlink Payload (prefix 0x0A):
798 798  
799 799  (% class="box infomessage" %)
... ... @@ -809,7 +809,6 @@
809 809  
810 810  There is no AT Command to poll uplink
811 811  
812 -
813 813  * Downlink Payload (prefix 0x08):
814 814  
815 815  (% class="box infomessage" %)
... ... @@ -836,7 +836,6 @@
836 836  
837 837  0: Disable Trigger Mode
838 838  
839 -
840 840  * Downlink Payload (prefix 0x0A 06):
841 841  
842 842  (% class="box infomessage" %)
... ... @@ -854,7 +854,6 @@
854 854  
855 855  There is no AT Command for this feature.
856 856  
857 -
858 858  * Downlink Payload (prefix 0x AB 06):
859 859  
860 860  (% class="box infomessage" %)
... ... @@ -875,7 +875,6 @@
875 875  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
876 876  )))
877 877  
878 -
879 879  **Example:**
880 880  
881 881  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -1115,7 +1115,7 @@
1115 1115  
1116 1116  
1117 1117  
1118 -==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1102 +=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
1119 1119  
1120 1120  * AT Command:
1121 1121  