... ... @@ -607,7 +607,6 @@
607 607  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
608 608  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
609 609  
610 -
611 611  **AT Command to set Trigger Condition**:
612 612  
613 613  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -659,17 +659,14 @@
659 659  
660 660   Yy4 yy4: AC2 or AV2 high limit.
661 661  
662 -
663 663  **Example1**: AA 00 13 88 00 00 00 00 00 00
664 664  
665 665  Same as AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
666 666  
667 -
668 668  **Example2**: AA 02 01 00
669 669  
670 670  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
671 671  
672 -
673 673  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
674 674  
675 675  MOD6 Payload : total 11 bytes payload
... ... @@ -676,7 +676,6 @@
676 676  
677 677  [[image:image-20220524085923-1.png]]
678 678  
679 -
680 680  (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below
681 681  
682 682  [[image:image-20220524090106-2.png]]
... ... @@ -683,7 +683,6 @@
683 683  
684 684  * Each bits shows if the corresponding trigger has been configured.
685 685  
686 -
687 687  **Example:**
688 688  
689 689  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -695,7 +695,6 @@
695 695  
696 696  * Each bits shows which status has been trigger on this uplink.
697 697  
698 -
699 699  **Example:**
700 700  
701 701  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -707,7 +707,6 @@
707 707  
708 708  * Each bits shows which status has been trigger on this uplink.
709 709  
710 -
711 711  **Example:**
712 712  
713 713  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -747,8 +747,6 @@
747 747  
748 748  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
749 749  
750 -
751 -
752 752  === 3.4.1 Common Commands ===
753 753  
754 754  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -770,7 +770,6 @@
770 770  
771 771  **Example: **AT+TDC=30000. Means set interval to 30 seconds
772 772  
773 -
774 774  * Downlink Payload (prefix 0x01):
775 775  
776 776  (% class="box infomessage" %)
... ... @@ -793,7 +793,6 @@
793 793  
794 794  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
795 795  
796 -
797 797  * Downlink Payload (prefix 0x0A):
798 798  
799 799  (% class="box infomessage" %)
... ... @@ -809,7 +809,6 @@
809 809  
810 810  There is no AT Command to poll uplink
811 811  
812 -
813 813  * Downlink Payload (prefix 0x08):
814 814  
815 815  (% class="box infomessage" %)
... ... @@ -836,7 +836,6 @@
836 836  
837 837  0: Disable Trigger Mode
838 838  
839 -
840 840  * Downlink Payload (prefix 0x0A 06):
841 841  
842 842  (% class="box infomessage" %)
... ... @@ -854,7 +854,6 @@
854 854  
855 855  There is no AT Command for this feature.
856 856  
857 -
858 858  * Downlink Payload (prefix 0x AB 06):
859 859  
860 860  (% class="box infomessage" %)
... ... @@ -875,7 +875,6 @@
875 875  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
876 876  )))
877 877  
878 -
879 879  **Example:**
880 880  
881 881  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -904,12 +904,10 @@
904 904  
905 905  b : delay timing.
906 906  
907 -
908 908  **Example:**
909 909  
910 910  AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms )
911 911  
912 -
913 913  * Downlink Payload (prefix 0x09 01 ):
914 914  
915 915  (% class="box infomessage" %)
... ... @@ -934,12 +934,10 @@
934 934  
935 935  b : delay timing.
936 936  
937 -
938 938  **Example:**
939 939  
940 940  AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms )
941 941  
942 -
943 943  * Downlink Payload (prefix 0x09 02 ):
944 944  
945 945  (% class="box infomessage" %)
... ... @@ -960,7 +960,6 @@
960 960  **AT+ACLIM. **
961 961  )))
962 962  
963 -
964 964  * Downlink Payload (prefix 0xAA 01 ):
965 965  
966 966  (% class="box infomessage" %)
... ... @@ -981,7 +981,6 @@
981 981  **AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
982 982  )))
983 983  
984 -
985 985  * Downlink Payload (prefix 0xAA 00 ):
986 986  
987 987  (% class="box infomessage" %)
... ... @@ -1002,7 +1002,6 @@
1002 1002  **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.**
1003 1003  )))
1004 1004  
1005 -
1006 1006  * Downlink Payload (prefix 0xAC ):
1007 1007  
1008 1008  (% class="box infomessage" %)
... ... @@ -1018,7 +1018,6 @@
1018 1018  
1019 1019  There is no AT Command to control Digital Output
1020 1020  
1021 -
1022 1022  * Downlink Payload (prefix 0x02):
1023 1023  
1024 1024  (% class="box infomessage" %)
... ... @@ -1052,7 +1052,6 @@
1052 1052  
1053 1053  There is no AT Command to control Digital Output
1054 1054  
1055 -
1056 1056  * Downlink Payload (prefix 0xA9):
1057 1057  
1058 1058  (% class="box infomessage" %)
... ... @@ -1072,22 +1072,18 @@
1072 1072  
1073 1073  00: DO pins will change to an inverter state after timeout 
1074 1074  
1075 -
1076 1076  (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status:
1077 1077  
1078 1078  [[image:image-20220524093238-6.png]]
1079 1079  
1080 -
1081 1081  (% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status:
1082 1082  
1083 1083  [[image:image-20220524093328-7.png]]
1084 1084  
1085 -
1086 1086  (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status:
1087 1087  
1088 1088  [[image:image-20220524093351-8.png]]
1089 1089  
1090 -
1091 1091  (% style="color:#4f81bd" %)**Sixth and Seventh Byte**:
1092 1092  
1093 1093   Latching time. Unit: ms
... ... @@ -1094,7 +1094,6 @@
1094 1094  
1095 1095  Device will upload a packet if downlink code executes successfully.
1096 1096  
1097 -
1098 1098  **Example payload:**
1099 1099  
1100 1100  **~1. A9 01 01 01 01 07 D0**
... ... @@ -1115,13 +1115,12 @@
1115 1115  
1116 1116  
1117 1117  
1118 -==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1088 +=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
1119 1119  
1120 1120  * AT Command:
1121 1121  
1122 1122  There is no AT Command to control Relay Output
1123 1123  
1124 -
1125 1125  * Downlink Payload (prefix 0x03):
1126 1126  
1127 1127  (% class="box infomessage" %)
... ... @@ -1151,7 +1151,6 @@
1151 1151  
1152 1152  There is no AT Command to control Relay Output
1153 1153  
1154 -
1155 1155  * Downlink Payload (prefix 0x05):
1156 1156  
1157 1157  (% class="box infomessage" %)
... ... @@ -1169,12 +1169,10 @@
1169 1169  
1170 1170  00: Relays will change to an inverter state after timeout
1171 1171  
1172 -
1173 1173  (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status:
1174 1174  
1175 1175  [[image:image-20220524093831-10.png]]
1176 1176  
1177 -
1178 1178  (% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms
1179 1179  
1180 1180  Device will upload a packet if downlink code executes successfully.
... ... @@ -1211,7 +1211,6 @@
1211 1211  **AT+VOLMAX    ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]**
1212 1212  )))
1213 1213  
1214 -
1215 1215  * Downlink Payload (prefix 0xA5):
1216 1216  
1217 1217  (% class="box infomessage" %)
... ... @@ -1238,7 +1238,6 @@
1238 1238  
1239 1239  Bb cc dd ee: number to be set
1240 1240  
1241 -
1242 1242  * Downlink Payload (prefix 0xA8):
1243 1243  
1244 1244  (% class="box infomessage" %)