<
From version < 77.75 >
edited by Xiaoling
on 2022/06/10 09:23
To version < 77.65 >
edited by Xiaoling
on 2022/06/10 09:19
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -658,17 +658,14 @@
658 658  
659 659   Yy4 yy4: AC2 or AV2 high limit.
660 660  
661 -
662 662  **Example1**: AA 00 13 88 00 00 00 00 00 00
663 663  
664 664  Same as AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
665 665  
666 -
667 667  **Example2**: AA 02 01 00
668 668  
669 669  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
670 670  
671 -
672 672  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
673 673  
674 674  MOD6 Payload : total 11 bytes payload
... ... @@ -675,7 +675,6 @@
675 675  
676 676  [[image:image-20220524085923-1.png]]
677 677  
678 -
679 679  (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below
680 680  
681 681  [[image:image-20220524090106-2.png]]
... ... @@ -682,7 +682,6 @@
682 682  
683 683  * Each bits shows if the corresponding trigger has been configured.
684 684  
685 -
686 686  **Example:**
687 687  
688 688  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -694,7 +694,6 @@
694 694  
695 695  * Each bits shows which status has been trigger on this uplink.
696 696  
697 -
698 698  **Example:**
699 699  
700 700  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -706,7 +706,6 @@
706 706  
707 707  * Each bits shows which status has been trigger on this uplink.
708 708  
709 -
710 710  **Example:**
711 711  
712 712  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -746,8 +746,6 @@
746 746  
747 747  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
748 748  
749 -
750 -
751 751  === 3.4.1 Common Commands ===
752 752  
753 753  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -769,7 +769,6 @@
769 769  
770 770  **Example: **AT+TDC=30000. Means set interval to 30 seconds
771 771  
772 -
773 773  * Downlink Payload (prefix 0x01):
774 774  
775 775  (% class="box infomessage" %)
... ... @@ -792,7 +792,6 @@
792 792  
793 793  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
794 794  
795 -
796 796  * Downlink Payload (prefix 0x0A):
797 797  
798 798  (% class="box infomessage" %)
... ... @@ -808,7 +808,6 @@
808 808  
809 809  There is no AT Command to poll uplink
810 810  
811 -
812 812  * Downlink Payload (prefix 0x08):
813 813  
814 814  (% class="box infomessage" %)
... ... @@ -835,7 +835,6 @@
835 835  
836 836  0: Disable Trigger Mode
837 837  
838 -
839 839  * Downlink Payload (prefix 0x0A 06):
840 840  
841 841  (% class="box infomessage" %)
... ... @@ -853,7 +853,6 @@
853 853  
854 854  There is no AT Command for this feature.
855 855  
856 -
857 857  * Downlink Payload (prefix 0x AB 06):
858 858  
859 859  (% class="box infomessage" %)
... ... @@ -874,7 +874,6 @@
874 874  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
875 875  )))
876 876  
877 -
878 878  **Example:**
879 879  
880 880  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -1114,7 +1114,7 @@
1114 1114  
1115 1115  
1116 1116  
1117 -==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1102 +=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
1118 1118  
1119 1119  * AT Command:
1120 1120  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0