From version < 77.74 >
edited by Xiaoling
on 2022/06/10 09:23
To version < 77.88 >
edited by Xiaoling
on 2022/06/10 09:27
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -310,6 +310,7 @@
310 310  * [1] RO1 relay channel is close and the RO1 LED is ON.
311 311  * [0] RO2 relay channel is open and RO2 LED is OFF;
312 312  
313 +
313 313  **LT22222-L:**
314 314  
315 315  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -325,8 +325,11 @@
325 325  ** DO1 is high in case there is load between DO1 and V+.
326 326  ** DO1 LED is off in both case
327 327  
329 +
330 +
328 328  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
329 329  
333 +
330 330  **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins.
331 331  
332 332  (((
... ... @@ -335,6 +335,7 @@
335 335  
336 336  [[image:image-20220523180452-3.png]]
337 337  
342 +
338 338  (((
339 339  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below
340 340  )))
... ... @@ -350,6 +350,8 @@
350 350  )))
351 351  
352 352  (((
358 +
359 +
353 353  **To use counting mode, please run:**
354 354  )))
355 355  
... ... @@ -368,6 +368,8 @@
368 368  )))
369 369  
370 370  (((
378 +
379 +
371 371  (% style="color:#4f81bd" %)**AT Commands for counting:**
372 372  )))
373 373  
... ... @@ -464,9 +464,9 @@
464 464  )))
465 465  
466 466  
467 -
468 468  === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting ===
469 469  
478 +
470 470  **LT22222-L**: This mode the DI1 is used as a counting pin.
471 471  
472 472  The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour.
... ... @@ -473,6 +473,7 @@
473 473  
474 474  [[image:image-20220523181903-8.png]]
475 475  
485 +
476 476  (((
477 477  (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
478 478  )))
... ... @@ -488,6 +488,8 @@
488 488  )))
489 489  
490 490  (((
501 +
502 +
491 491  **To use this mode, please run:**
492 492  )))
493 493  
... ... @@ -514,6 +514,8 @@
514 514  )))
515 515  
516 516  (((
529 +
530 +
517 517  **Plus below command for AVI1 Counting:**
518 518  )))
519 519  
... ... @@ -549,11 +549,14 @@
549 549  
550 550  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
551 551  
566 +
552 552  **LT22222-L**: This mode the DI1 is used as a counting pin.
553 553  
554 554  [[image:image-20220523182334-9.png]]
555 555  
556 556  (((
572 +
573 +
557 557  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
558 558  )))
559 559  
... ... @@ -568,6 +568,8 @@
568 568  )))
569 569  
570 570  (((
588 +
589 +
571 571  **To use this mode, please run:**
572 572  )))
573 573  
... ... @@ -587,8 +587,6 @@
587 587  
588 588  (((
589 589  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
590 -
591 -
592 592  )))
593 593  
594 594  
... ... @@ -595,6 +595,7 @@
595 595  
596 596  === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) ===
597 597  
615 +
598 598  (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.**
599 599  
600 600  For example, if user has configured below commands:
... ... @@ -658,10 +658,12 @@
658 658  
659 659   Yy4 yy4: AC2 or AV2 high limit.
660 660  
679 +
661 661  **Example1**: AA 00 13 88 00 00 00 00 00 00
662 662  
663 663  Same as AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
664 664  
684 +
665 665  **Example2**: AA 02 01 00
666 666  
667 667  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -680,7 +680,6 @@
680 680  
681 681  * Each bits shows if the corresponding trigger has been configured.
682 682  
683 -
684 684  **Example:**
685 685  
686 686  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -692,7 +692,6 @@
692 692  
693 693  * Each bits shows which status has been trigger on this uplink.
694 694  
695 -
696 696  **Example:**
697 697  
698 698  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -724,6 +724,8 @@
724 724  === 3.3.7 Payload Decoder ===
725 725  
726 726  (((
745 +
746 +
727 727  **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]]
728 728  
729 729  
... ... @@ -744,7 +744,6 @@
744 744  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
745 745  
746 746  
747 -
748 748  === 3.4.1 Common Commands ===
749 749  
750 750  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0