... ... @@ -607,6 +607,7 @@
607 607  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
608 608  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
609 609  
610 +
610 610  **AT Command to set Trigger Condition**:
611 611  
612 612  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -658,10 +658,12 @@
658 658  
659 659   Yy4 yy4: AC2 or AV2 high limit.
660 660  
662 +
661 661  **Example1**: AA 00 13 88 00 00 00 00 00 00
662 662  
663 663  Same as AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
664 664  
667 +
665 665  **Example2**: AA 02 01 00
666 666  
667 667  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -704,6 +704,7 @@
704 704  
705 705  * Each bits shows which status has been trigger on this uplink.
706 706  
710 +
707 707  **Example:**
708 708  