<
From version < 77.73 >
edited by Xiaoling
on 2022/06/10 09:23
To version < 77.62 >
edited by Xiaoling
on 2022/06/10 09:15
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -666,7 +666,6 @@
666 666  
667 667  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
668 668  
669 -
670 670  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
671 671  
672 672  MOD6 Payload : total 11 bytes payload
... ... @@ -673,7 +673,6 @@
673 673  
674 674  [[image:image-20220524085923-1.png]]
675 675  
676 -
677 677  (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below
678 678  
679 679  [[image:image-20220524090106-2.png]]
... ... @@ -680,7 +680,6 @@
680 680  
681 681  * Each bits shows if the corresponding trigger has been configured.
682 682  
683 -
684 684  **Example:**
685 685  
686 686  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -692,7 +692,6 @@
692 692  
693 693  * Each bits shows which status has been trigger on this uplink.
694 694  
695 -
696 696  **Example:**
697 697  
698 698  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -743,8 +743,6 @@
743 743  
744 744  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
745 745  
746 -
747 -
748 748  === 3.4.1 Common Commands ===
749 749  
750 750  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -766,7 +766,6 @@
766 766  
767 767  **Example: **AT+TDC=30000. Means set interval to 30 seconds
768 768  
769 -
770 770  * Downlink Payload (prefix 0x01):
771 771  
772 772  (% class="box infomessage" %)
... ... @@ -789,7 +789,6 @@
789 789  
790 790  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
791 791  
792 -
793 793  * Downlink Payload (prefix 0x0A):
794 794  
795 795  (% class="box infomessage" %)
... ... @@ -805,7 +805,6 @@
805 805  
806 806  There is no AT Command to poll uplink
807 807  
808 -
809 809  * Downlink Payload (prefix 0x08):
810 810  
811 811  (% class="box infomessage" %)
... ... @@ -832,7 +832,6 @@
832 832  
833 833  0: Disable Trigger Mode
834 834  
835 -
836 836  * Downlink Payload (prefix 0x0A 06):
837 837  
838 838  (% class="box infomessage" %)
... ... @@ -850,7 +850,6 @@
850 850  
851 851  There is no AT Command for this feature.
852 852  
853 -
854 854  * Downlink Payload (prefix 0x AB 06):
855 855  
856 856  (% class="box infomessage" %)
... ... @@ -871,7 +871,6 @@
871 871  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
872 872  )))
873 873  
874 -
875 875  **Example:**
876 876  
877 877  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -900,12 +900,10 @@
900 900  
901 901  b : delay timing.
902 902  
903 -
904 904  **Example:**
905 905  
906 906  AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms )
907 907  
908 -
909 909  * Downlink Payload (prefix 0x09 01 ):
910 910  
911 911  (% class="box infomessage" %)
... ... @@ -930,12 +930,10 @@
930 930  
931 931  b : delay timing.
932 932  
933 -
934 934  **Example:**
935 935  
936 936  AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms )
937 937  
938 -
939 939  * Downlink Payload (prefix 0x09 02 ):
940 940  
941 941  (% class="box infomessage" %)
... ... @@ -956,7 +956,6 @@
956 956  **AT+ACLIM. **
957 957  )))
958 958  
959 -
960 960  * Downlink Payload (prefix 0xAA 01 ):
961 961  
962 962  (% class="box infomessage" %)
... ... @@ -977,7 +977,6 @@
977 977  **AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
978 978  )))
979 979  
980 -
981 981  * Downlink Payload (prefix 0xAA 00 ):
982 982  
983 983  (% class="box infomessage" %)
... ... @@ -998,7 +998,6 @@
998 998  **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.**
999 999  )))
1000 1000  
1001 -
1002 1002  * Downlink Payload (prefix 0xAC ):
1003 1003  
1004 1004  (% class="box infomessage" %)
... ... @@ -1014,7 +1014,6 @@
1014 1014  
1015 1015  There is no AT Command to control Digital Output
1016 1016  
1017 -
1018 1018  * Downlink Payload (prefix 0x02):
1019 1019  
1020 1020  (% class="box infomessage" %)
... ... @@ -1048,7 +1048,6 @@
1048 1048  
1049 1049  There is no AT Command to control Digital Output
1050 1050  
1051 -
1052 1052  * Downlink Payload (prefix 0xA9):
1053 1053  
1054 1054  (% class="box infomessage" %)
... ... @@ -1068,22 +1068,18 @@
1068 1068  
1069 1069  00: DO pins will change to an inverter state after timeout 
1070 1070  
1071 -
1072 1072  (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status:
1073 1073  
1074 1074  [[image:image-20220524093238-6.png]]
1075 1075  
1076 -
1077 1077  (% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status:
1078 1078  
1079 1079  [[image:image-20220524093328-7.png]]
1080 1080  
1081 -
1082 1082  (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status:
1083 1083  
1084 1084  [[image:image-20220524093351-8.png]]
1085 1085  
1086 -
1087 1087  (% style="color:#4f81bd" %)**Sixth and Seventh Byte**:
1088 1088  
1089 1089   Latching time. Unit: ms
... ... @@ -1090,7 +1090,6 @@
1090 1090  
1091 1091  Device will upload a packet if downlink code executes successfully.
1092 1092  
1093 -
1094 1094  **Example payload:**
1095 1095  
1096 1096  **~1. A9 01 01 01 01 07 D0**
... ... @@ -1111,13 +1111,12 @@
1111 1111  
1112 1112  
1113 1113  
1114 -==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1088 +=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
1115 1115  
1116 1116  * AT Command:
1117 1117  
1118 1118  There is no AT Command to control Relay Output
1119 1119  
1120 -
1121 1121  * Downlink Payload (prefix 0x03):
1122 1122  
1123 1123  (% class="box infomessage" %)
... ... @@ -1147,7 +1147,6 @@
1147 1147  
1148 1148  There is no AT Command to control Relay Output
1149 1149  
1150 -
1151 1151  * Downlink Payload (prefix 0x05):
1152 1152  
1153 1153  (% class="box infomessage" %)
... ... @@ -1165,12 +1165,10 @@
1165 1165  
1166 1166  00: Relays will change to an inverter state after timeout
1167 1167  
1168 -
1169 1169  (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status:
1170 1170  
1171 1171  [[image:image-20220524093831-10.png]]
1172 1172  
1173 -
1174 1174  (% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms
1175 1175  
1176 1176  Device will upload a packet if downlink code executes successfully.
... ... @@ -1207,7 +1207,6 @@
1207 1207  **AT+VOLMAX    ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]**
1208 1208  )))
1209 1209  
1210 -
1211 1211  * Downlink Payload (prefix 0xA5):
1212 1212  
1213 1213  (% class="box infomessage" %)
... ... @@ -1234,7 +1234,6 @@
1234 1234  
1235 1235  Bb cc dd ee: number to be set
1236 1236  
1237 -
1238 1238  * Downlink Payload (prefix 0xA8):
1239 1239  
1240 1240  (% class="box infomessage" %)
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0