Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -19,6 +19,8 @@ 19 19 == 1.1 What is LT Series I/O Controller == 20 20 21 21 ((( 22 + 23 + 22 22 The Dragino (% style="color:blue" %)**LT series I/O Modules**(%%) are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (% style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %), **relay output**, **digital input**(%%) and (% style="color:blue" %)**digital output**(%%) etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring. 23 23 ))) 24 24 ... ... @@ -48,6 +48,7 @@ 48 48 49 49 ))) 50 50 53 + 51 51 == 1.2 Specifications == 52 52 53 53 ((( ... ... @@ -76,6 +76,8 @@ 76 76 ))) 77 77 78 78 ((( 82 + 83 + 79 79 **Interface for Model: LT22222-L:** 80 80 ))) 81 81 ... ... @@ -99,6 +99,8 @@ 99 99 ))) 100 100 101 101 ((( 107 + 108 + 102 102 **LoRa Spec:** 103 103 ))) 104 104 ... ... @@ -159,6 +159,8 @@ 159 159 * ((( 160 160 Packet engine up to 256 bytes with CRC. 161 161 169 + 170 + 162 162 163 163 ))) 164 164 ... ... @@ -172,6 +172,8 @@ 172 172 * Firmware upgradable via program port 173 173 * Counting 174 174 184 + 185 + 175 175 == 1.4 Applications == 176 176 177 177 * Smart Buildings & Home Automation ... ... @@ -181,6 +181,8 @@ 181 181 * Smart Cities 182 182 * Smart Factory 183 183 195 + 196 + 184 184 == 1.5 Hardware Variants == 185 185 186 186 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -194,6 +194,7 @@ 194 194 * 1 x Counting Port 195 195 ))) 196 196 210 + 197 197 = 2. Power ON Device = 198 198 199 199 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -216,12 +216,9 @@ 216 216 217 217 ((( 218 218 In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 219 - 220 - 221 221 ))) 222 222 223 223 224 - 225 225 == 3.2 Example to join LoRaWAN network == 226 226 227 227 ((( ... ... @@ -230,12 +230,13 @@ 230 230 231 231 [[image:image-20220523172350-1.png||height="266" width="864"]] 232 232 244 + 233 233 ((( 234 234 The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN: 235 235 ))) 236 236 237 237 ((( 238 -**Step 1**: Create a device in TTN with the OTAA keys from LT IO controller. 250 +(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller. 239 239 ))) 240 240 241 241 ((( ... ... @@ -244,6 +244,7 @@ 244 244 245 245 [[image:1653297924498-393.png]] 246 246 259 + 247 247 Input these keys in the LoRaWAN Server portal. Below is TTN screen shot: 248 248 249 249 Add APP EUI in the application. ... ... @@ -257,7 +257,7 @@ 257 257 258 258 259 259 ((( 260 -**Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 273 +(% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 261 261 ))) 262 262 263 263 [[image:1653298044601-602.png||height="405" width="709"]] ... ... @@ -275,6 +275,8 @@ 275 275 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 276 276 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 277 277 291 + 292 + 278 278 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 279 279 280 280 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -282,6 +282,8 @@ 282 282 [[image:image-20220523174024-3.png]] 283 283 284 284 ((( 300 + 301 + 285 285 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 286 286 ))) 287 287 ... ... @@ -295,6 +295,7 @@ 295 295 296 296 For example if payload is: [[image:image-20220523175847-2.png]] 297 297 315 + 298 298 **The value for the interface is: ** 299 299 300 300 AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V ... ... @@ -325,8 +325,11 @@ 325 325 ** DO1 is high in case there is load between DO1 and V+. 326 326 ** DO1 LED is off in both case 327 327 346 + 347 + 328 328 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 329 329 350 + 330 330 **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins. 331 331 332 332 ((( ... ... @@ -335,6 +335,7 @@ 335 335 336 336 [[image:image-20220523180452-3.png]] 337 337 359 + 338 338 ((( 339 339 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below 340 340 ))) ... ... @@ -350,6 +350,8 @@ 350 350 ))) 351 351 352 352 ((( 375 + 376 + 353 353 **To use counting mode, please run:** 354 354 ))) 355 355 ... ... @@ -357,17 +357,14 @@ 357 357 ((( 358 358 ((( 359 359 **AT+MOD=2** 360 -))) 361 -))) 362 362 363 -(% class="box infomessage" %) 364 -((( 365 -((( 366 366 **ATZ** 367 367 ))) 368 368 ))) 369 369 370 370 ((( 390 + 391 + 371 371 (% style="color:#4f81bd" %)**AT Commands for counting:** 372 372 ))) 373 373 ... ... @@ -379,40 +379,15 @@ 379 379 ((( 380 380 ((( 381 381 **AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 382 -))) 383 -))) 384 384 385 -(% class="box infomessage" %) 386 -((( 387 -((( 388 388 **AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 389 -))) 390 -))) 391 391 392 -(% class="box infomessage" %) 393 -((( 394 -((( 395 395 **AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 396 -))) 397 -))) 398 398 399 -(% class="box infomessage" %) 400 -((( 401 -((( 402 402 **AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 403 -))) 404 -))) 405 405 406 -(% class="box infomessage" %) 407 -((( 408 -((( 409 409 **AT+SETCNT=1,60 (Set COUNT1 value to 60)** 410 -))) 411 -))) 412 412 413 -(% class="box infomessage" %) 414 -((( 415 -((( 416 416 **AT+SETCNT=2,60 (Set COUNT2 value to 60)** 417 417 ))) 418 418 ))) ... ... @@ -447,12 +447,7 @@ 447 447 ((( 448 448 ((( 449 449 **AT+MOD=3** 450 -))) 451 -))) 452 452 453 -(% class="box infomessage" %) 454 -((( 455 -((( 456 456 **ATZ** 457 457 ))) 458 458 ))) ... ... @@ -459,8 +459,6 @@ 459 459 460 460 ((( 461 461 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 462 - 463 - 464 464 ))) 465 465 466 466 ... ... @@ -467,6 +467,7 @@ 467 467 468 468 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 469 469 459 + 470 470 **LT22222-L**: This mode the DI1 is used as a counting pin. 471 471 472 472 The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour. ... ... @@ -473,6 +473,7 @@ 473 473 474 474 [[image:image-20220523181903-8.png]] 475 475 466 + 476 476 ((( 477 477 (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 478 478 ))) ... ... @@ -488,6 +488,8 @@ 488 488 ))) 489 489 490 490 ((( 482 + 483 + 491 491 **To use this mode, please run:** 492 492 ))) 493 493 ... ... @@ -495,25 +495,20 @@ 495 495 ((( 496 496 ((( 497 497 **AT+MOD=4** 498 -))) 499 -))) 500 500 501 -(% class="box infomessage" %) 502 -((( 503 -((( 504 504 **ATZ** 505 505 ))) 506 506 ))) 507 507 508 -((( 509 - 510 -))) 511 511 497 + 512 512 ((( 513 513 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 514 514 ))) 515 515 516 516 ((( 503 + 504 + 517 517 **Plus below command for AVI1 Counting:** 518 518 ))) 519 519 ... ... @@ -520,40 +520,27 @@ 520 520 (% class="box infomessage" %) 521 521 ((( 522 522 ((( 523 -**AT+SETCNT=3,60 (set AVI Count to 60)** 524 -))) 525 -))) 511 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 526 526 527 -(% class="box infomessage" %) 528 -((( 529 -((( 530 -**AT+VOLMAX=20000 (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 531 -))) 532 -))) 513 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 533 533 534 -(% class="box infomessage" %) 535 -((( 536 -((( 537 -**AT+VOLMAX=20000,0 (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 538 -))) 539 -))) 515 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 540 540 541 -(% class="box infomessage" %) 542 -((( 543 -((( 544 -**AT+VOLMAX=20000,1 (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 517 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 545 545 ))) 546 546 ))) 547 547 548 548 549 - 550 550 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 551 551 524 + 552 552 **LT22222-L**: This mode the DI1 is used as a counting pin. 553 553 554 554 [[image:image-20220523182334-9.png]] 555 555 556 556 ((( 530 + 531 + 557 557 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 558 558 ))) 559 559 ... ... @@ -568,6 +568,8 @@ 568 568 ))) 569 569 570 570 ((( 546 + 547 + 571 571 **To use this mode, please run:** 572 572 ))) 573 573 ... ... @@ -575,12 +575,7 @@ 575 575 ((( 576 576 ((( 577 577 **AT+MOD=5** 578 -))) 579 -))) 580 580 581 -(% class="box infomessage" %) 582 -((( 583 -((( 584 584 **ATZ** 585 585 ))) 586 586 ))) ... ... @@ -587,8 +587,6 @@ 587 587 588 588 ((( 589 589 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 590 - 591 - 592 592 ))) 593 593 594 594 ... ... @@ -595,6 +595,7 @@ 595 595 596 596 === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === 597 597 568 + 598 598 (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.** 599 599 600 600 For example, if user has configured below commands: ... ... @@ -607,7 +607,7 @@ 607 607 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 608 608 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 609 609 610 -**AT Command to set Trigger Condition**: 581 +(% style="color:#037691" %)**AT Command to set Trigger Condition**: 611 611 612 612 (% style="color:#4f81bd" %)**Trigger base on voltage**: 613 613 ... ... @@ -620,6 +620,7 @@ 620 620 AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 621 621 622 622 594 + 623 623 (% style="color:#4f81bd" %)**Trigger base on current**: 624 624 625 625 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> ... ... @@ -629,6 +629,7 @@ 629 629 AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) 630 630 631 631 604 + 632 632 (% style="color:#4f81bd" %)**Trigger base on DI status**: 633 633 634 634 DI status trigger Flag. ... ... @@ -635,12 +635,13 @@ 635 635 636 636 Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG > 637 637 611 + 638 638 **Example:** 639 639 640 640 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 641 641 642 642 643 -**Downlink Command to set Trigger Condition** 617 +(% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 644 644 645 645 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 646 646 ... ... @@ -658,15 +658,18 @@ 658 658 659 659 Yy4 yy4: AC2 or AV2 high limit. 660 660 635 + 661 661 **Example1**: AA 00 13 88 00 00 00 00 00 00 662 662 663 663 Same as AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 664 664 640 + 665 665 **Example2**: AA 02 01 00 666 666 667 667 Same as AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 668 668 669 669 646 + 670 670 (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:** 671 671 672 672 MOD6 Payload : total 11 bytes payload ... ... @@ -680,7 +680,6 @@ 680 680 681 681 * Each bits shows if the corresponding trigger has been configured. 682 682 683 - 684 684 **Example:** 685 685 686 686 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -723,6 +723,8 @@ 723 723 === 3.3.7 Payload Decoder === 724 724 725 725 ((( 702 + 703 + 726 726 **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]] 727 727 728 728 ... ... @@ -729,7 +729,6 @@ 729 729 ))) 730 730 731 731 732 - 733 733 == 3.4 Configure LT via AT or Downlink == 734 734 735 735 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands ... ... @@ -756,7 +756,7 @@ 756 756 757 757 Set device uplink interval. 758 758 759 -* AT Command: 736 +* (% style="color:#037691" %)**AT Command:** 760 760 761 761 (% class="box infomessage" %) 762 762 ((( ... ... @@ -766,7 +766,7 @@ 766 766 **Example: **AT+TDC=30000. Means set interval to 30 seconds 767 767 768 768 769 -* Downlink Payload (prefix 0x01): 746 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 770 770 771 771 (% class="box infomessage" %) 772 772 ((( ... ... @@ -779,7 +779,7 @@ 779 779 780 780 Set work mode. 781 781 782 -* AT Command: 759 +* (% style="color:#037691" %)**AT Command:** 783 783 784 784 (% class="box infomessage" %) 785 785 ((( ... ... @@ -789,7 +789,7 @@ 789 789 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 790 790 791 791 792 -* Downlink Payload (prefix 0x0A): 769 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 793 793 794 794 (% class="box infomessage" %) 795 795 ((( ... ... @@ -800,12 +800,12 @@ 800 800 801 801 ==== 3.4.2.3 Poll an uplink ==== 802 802 803 -* AT Command: 780 +* (% style="color:#037691" %)AT Command: 804 804 805 805 There is no AT Command to poll uplink 806 806 807 807 808 -* Downlink Payload (prefix 0x08): 785 +* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 809 809 810 810 (% class="box infomessage" %) 811 811 ((( ... ... @@ -820,7 +820,7 @@ 820 820 821 821 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 822 822 823 -* AT Command: 800 +* (% style="color:#037691" %)AT Command: 824 824 825 825 (% class="box infomessage" %) 826 826 ((( ... ... @@ -832,7 +832,7 @@ 832 832 0: Disable Trigger Mode 833 833 834 834 835 -* Downlink Payload (prefix 0x0A 06): 812 +* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 836 836 837 837 (% class="box infomessage" %) 838 838 ((( ... ... @@ -845,12 +845,12 @@ 845 845 846 846 Poll trigger settings, 847 847 848 -* AT Command: 825 +* (% style="color:#037691" %)AT Command: 849 849 850 850 There is no AT Command for this feature. 851 851 852 852 853 -* Downlink Payload (prefix 0x AB 06): 830 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 854 854 855 855 (% class="box infomessage" %) 856 856 ((( ... ... @@ -863,7 +863,7 @@ 863 863 864 864 Enable Disable DI1/DI2/DI2 as trigger, 865 865 866 -* AT Command: 843 +* (% style="color:#037691" %)AT Command: 867 867 868 868 (% class="box infomessage" %) 869 869 ((( ... ... @@ -875,7 +875,7 @@ 875 875 876 876 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 877 877 878 -* Downlink Payload (prefix 0xAA 02): 855 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 879 879 880 880 (% class="box infomessage" %) 881 881 ((( ... ... @@ -888,7 +888,7 @@ 888 888 889 889 Set DI1 or DI3(for LT-33222-L) trigger. 890 890 891 -* AT Command: 868 +* (% style="color:#037691" %)AT Command: 892 892 893 893 (% class="box infomessage" %) 894 894 ((( ... ... @@ -905,7 +905,7 @@ 905 905 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 906 906 907 907 908 -* Downlink Payload (prefix 0x09 01 ): 885 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ): 909 909 910 910 (% class="box infomessage" %) 911 911 ((( ... ... @@ -918,7 +918,7 @@ 918 918 919 919 Set DI2 trigger. 920 920 921 -* AT Command: 898 +* (% style="color:#037691" %)AT Command: 922 922 923 923 (% class="box infomessage" %) 924 924 ((( ... ... @@ -935,7 +935,7 @@ 935 935 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 936 936 937 937 938 -* Downlink Payload (prefix 0x09 02 ): 915 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 02 ): 939 939 940 940 (% class="box infomessage" %) 941 941 ((( ... ... @@ -948,7 +948,7 @@ 948 948 949 949 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 950 950 951 -* AT Command: 928 +* (% style="color:#037691" %)AT Command: 952 952 953 953 (% class="box infomessage" %) 954 954 ((( ... ... @@ -956,7 +956,7 @@ 956 956 ))) 957 957 958 958 959 -* Downlink Payload (prefix 0xAA 01 ): 936 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 01 ): 960 960 961 961 (% class="box infomessage" %) 962 962 ((( ... ... @@ -969,7 +969,7 @@ 969 969 970 970 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 971 971 972 -* AT Command: 949 +* (% style="color:#037691" %)AT Command: 973 973 974 974 (% class="box infomessage" %) 975 975 ((( ... ... @@ -977,7 +977,7 @@ 977 977 ))) 978 978 979 979 980 -* Downlink Payload (prefix 0xAA 00 ): 957 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 00 ): 981 981 982 982 (% class="box infomessage" %) 983 983 ((( ... ... @@ -990,7 +990,7 @@ 990 990 991 991 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 992 992 993 -* AT Command: 970 +* (% style="color:#037691" %)AT Command: 994 994 995 995 (% class="box infomessage" %) 996 996 ((( ... ... @@ -998,7 +998,7 @@ 998 998 ))) 999 999 1000 1000 1001 -* Downlink Payload (prefix 0xAC ): 978 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAC ): 1002 1002 1003 1003 (% class="box infomessage" %) 1004 1004 ((( ... ... @@ -1009,12 +1009,12 @@ 1009 1009 1010 1010 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 1011 1011 1012 -* AT Command: 989 +* (% style="color:#037691" %)AT Command: 1013 1013 1014 1014 There is no AT Command to control Digital Output 1015 1015 1016 1016 1017 -* Downlink Payload (prefix 0x02): 994 +* (% style="color:#037691" %)Downlink Payload (prefix 0x02): 1018 1018 1019 1019 (% class="box infomessage" %) 1020 1020 ((( ... ... @@ -1043,12 +1043,12 @@ 1043 1043 1044 1044 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1045 1045 1046 -* AT Command: 1023 +* (% style="color:#037691" %)AT Command: 1047 1047 1048 1048 There is no AT Command to control Digital Output 1049 1049 1050 1050 1051 -* Downlink Payload (prefix 0xA9): 1028 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA9): 1052 1052 1053 1053 (% class="box infomessage" %) 1054 1054 ((( ... ... @@ -1112,18 +1112,16 @@ 1112 1112 1113 1113 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1114 1114 1115 -* AT Command: 1092 +* (% style="color:#037691" %)**AT Command:** 1116 1116 1117 1117 There is no AT Command to control Relay Output 1118 1118 1119 1119 1120 -* Downlink Payload (prefix 0x03): 1097 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x03):** 1121 1121 1122 -(% class="box infomessage" %) 1123 -((( 1124 -**0x03 aa bb ~/~/ Set RO1/RO2 output** 1125 -))) 1099 +**0x03 aa bb **~/~/ Set RO1/RO2 output 1126 1126 1101 + 1127 1127 ((( 1128 1128 If payload = 0x030100, it means set RO1 to close and RO2 to open. 1129 1129 ))) ... ... @@ -1140,20 +1140,19 @@ 1140 1140 1141 1141 1142 1142 1118 + 1143 1143 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1144 1144 1145 -* AT Command: 1121 +* (% style="color:#037691" %)**AT Command:** 1146 1146 1147 1147 There is no AT Command to control Relay Output 1148 1148 1149 1149 1150 -* Downlink Payload (prefix 0x05): 1126 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x05):** 1151 1151 1152 -(% class="box infomessage" %) 1153 -((( 1154 -**0x05 aa bb cc dd ~/~/ Set RO1/RO2 relay with time control:** 1155 -))) 1128 +**0x05 aa bb cc dd **~/~/ Set RO1/RO2 relay with time control 1156 1156 1130 + 1157 1157 This is to control the relay output time of relay. Include four bytes: 1158 1158 1159 1159 (% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05) ... ... @@ -1195,35 +1195,28 @@ 1195 1195 1196 1196 1197 1197 1172 + 1198 1198 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1199 1199 1200 1200 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1201 1201 1202 -* AT Command: 1177 +* (% style="color:#037691" %)**AT Command:** 1203 1203 1204 -(% class="box infomessage" %) 1205 -((( 1206 -**AT+VOLMAX ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]** 1207 -))) 1179 +(% style="color:#037691" %)****(%%)**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1208 1208 1209 1209 1210 -* Downlink Payload (prefix 0xA5): 1182 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** 1211 1211 1212 -(% class="box infomessage" %) 1213 -((( 1214 -**0xA5 aa bb cc ~/~/ Same as AT+VOLMAX=(aa bb),cc** 1215 -))) 1184 +**0xA5 aa bb cc **~/~/ Same as AT+VOLMAX=(aa bb),cc 1216 1216 1217 1217 1218 1218 1188 + 1219 1219 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1220 1220 1221 -* AT Command: 1191 +* (% style="color:#037691" %)**AT Command:** 1222 1222 1223 -(% class="box infomessage" %) 1224 -((( 1225 -**AT+SETCNT=aa,(bb cc dd ee) ** 1226 -))) 1193 +(% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) ** 1227 1227 1228 1228 aa: 1: Set count1, 1229 1229 ... ... @@ -1234,51 +1234,40 @@ 1234 1234 Bb cc dd ee: number to be set 1235 1235 1236 1236 1237 -* Downlink Payload (prefix 0xA8): 1204 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA8):** 1238 1238 1239 -(% class="box infomessage" %) 1240 -((( 1241 -**0x A8 aa bb cc dd ee ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)** 1242 -))) 1206 +**0x A8 aa bb cc dd ee **~/~/ same as AT+SETCNT=aa,(bb cc dd ee) 1243 1243 1244 1244 1245 1245 1210 + 1246 1246 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1247 1247 1248 1248 Clear counting for counting mode 1249 1249 1250 -* AT Command: 1215 +* (% style="color:#037691" %)**AT Command:** 1251 1251 1252 -(% class="box infomessage" %) 1253 -((( 1254 -**AT+CLRCOUNT ~/~/ clear all counting** 1255 -))) 1217 +(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1256 1256 1257 -* Downlink Payload (prefix 0xA6): 1258 1258 1259 -(% class="box infomessage" %) 1260 -((( 1261 -**0x A6 01 ~/~/ clear all counting,** 1262 -))) 1220 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** 1263 1263 1222 +**0x A6 01 ** ~/~/ clear all counting 1264 1264 1265 1265 1225 + 1226 + 1266 1266 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1267 1267 1268 -* AT Command: 1229 +* (% style="color:#037691" %)**AT Command:** 1269 1269 1270 -(% class="box infomessage" %) 1271 -((( 1272 -**AT+COUTIME=60 ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)** 1273 -))) 1231 +**AT+COUTIME=60 **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) 1274 1274 1275 -* Downlink Payload (prefix 0xA7): 1276 1276 1277 -(% class="box infomessage" %) 1278 -((( 1279 -**0x A7 aa bb cc ~/~/ same as AT+COUTIME =aa bb cc,** 1280 -))) 1234 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA7):** 1281 1281 1236 +**0x A7 aa bb cc **~/~/ same as AT+COUTIME =aa bb cc, 1237 + 1282 1282 ((( 1283 1283 range: aa bb cc:0 to 16777215, (unit:second) 1284 1284 ... ... @@ -1286,6 +1286,7 @@ 1286 1286 ))) 1287 1287 1288 1288 1245 + 1289 1289 == 3.5 Integrate with Mydevice == 1290 1290 1291 1291 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: ... ... @@ -1975,8 +1975,16 @@ 1975 1975 ))) 1976 1976 1977 1977 ((( 1978 - 1935 +== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? == 1979 1979 1937 +If the device is not shut down, but directly powered off. 1938 + 1939 +It will default that this is a power-off state. 1940 + 1941 +In modes 2 to 5, DO RO status and pulse count are saved in flash. 1942 + 1943 +After restart, the status before power failure will be read from flash. 1944 + 1980 1980 = 6. Trouble Shooting = 1981 1981 ))) 1982 1982