... ... @@ -666,7 +666,6 @@
666 666  
667 667  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
668 668  
669 -
670 670  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
671 671  
672 672  MOD6 Payload : total 11 bytes payload
... ... @@ -673,7 +673,6 @@
673 673  
674 674  [[image:image-20220524085923-1.png]]
675 675  
676 -
677 677  (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below
678 678  
679 679  [[image:image-20220524090106-2.png]]
... ... @@ -680,7 +680,6 @@
680 680  
681 681  * Each bits shows if the corresponding trigger has been configured.
682 682  
683 -
684 684  **Example:**
685 685  
686 686  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -741,9 +741,8 @@
741 741  * (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
742 742  
743 743  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
741 +*
744 744  
745 -
746 -
747 747  === 3.4.1 Common Commands ===
748 748  
749 749  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -1110,7 +1110,7 @@
1110 1110  
1111 1111  
1112 1112  
1113 -==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1109 +=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
1114 1114  
1115 1115  * AT Command:
1116 1116  