... ... @@ -666,7 +666,6 @@
666 666  
667 667  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
668 668  
669 -
670 670  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
671 671  
672 672  MOD6 Payload : total 11 bytes payload
... ... @@ -673,7 +673,6 @@
673 673  
674 674  [[image:image-20220524085923-1.png]]
675 675  
676 -
677 677  (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below
678 678  
679 679  [[image:image-20220524090106-2.png]]
... ... @@ -680,7 +680,6 @@
680 680  
681 681  * Each bits shows if the corresponding trigger has been configured.
682 682  
683 -
684 684  **Example:**
685 685  
686 686  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -742,8 +742,6 @@
742 742  
743 743  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
744 744  
745 -
746 -
747 747  === 3.4.1 Common Commands ===
748 748  
749 749  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -765,7 +765,6 @@
765 765  
766 766  **Example: **AT+TDC=30000. Means set interval to 30 seconds
767 767  
768 -
769 769  * Downlink Payload (prefix 0x01):
770 770  
771 771  (% class="box infomessage" %)
... ... @@ -788,7 +788,6 @@
788 788  
789 789  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
790 790  
791 -
792 792  * Downlink Payload (prefix 0x0A):
793 793  
794 794  (% class="box infomessage" %)
... ... @@ -804,7 +804,6 @@
804 804  
805 805  There is no AT Command to poll uplink
806 806  
807 -
808 808  * Downlink Payload (prefix 0x08):
809 809  
810 810  (% class="box infomessage" %)
... ... @@ -831,7 +831,6 @@
831 831  
832 832  0: Disable Trigger Mode
833 833  
834 -
835 835  * Downlink Payload (prefix 0x0A 06):
836 836  
837 837  (% class="box infomessage" %)
... ... @@ -849,7 +849,6 @@
849 849  
850 850  There is no AT Command for this feature.
851 851  
852 -
853 853  * Downlink Payload (prefix 0x AB 06):
854 854  
855 855  (% class="box infomessage" %)
... ... @@ -870,7 +870,6 @@
870 870  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
871 871  )))
872 872  
873 -
874 874  **Example:**
875 875  
876 876  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -1110,7 +1110,7 @@
1110 1110  