... ... @@ -666,7 +666,6 @@
666 666  
667 667  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
668 668  
669 -
670 670  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
671 671  
672 672  MOD6 Payload : total 11 bytes payload
... ... @@ -673,7 +673,6 @@
673 673  
674 674  [[image:image-20220524085923-1.png]]
675 675  
676 -
677 677  (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below
678 678  
679 679  [[image:image-20220524090106-2.png]]
... ... @@ -680,7 +680,6 @@
680 680  
681 681  * Each bits shows if the corresponding trigger has been configured.
682 682  
683 -
684 684  **Example:**
685 685  
686 686  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -742,8 +742,6 @@
742 742  
743 743  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
744 744  
745 -
746 -
747 747  === 3.4.1 Common Commands ===
748 748  
749 749  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -765,7 +765,6 @@
765 765  
766 766  **Example: **AT+TDC=30000. Means set interval to 30 seconds
767 767  
768 -
769 769  * Downlink Payload (prefix 0x01):
770 770  
771 771  (% class="box infomessage" %)
... ... @@ -788,7 +788,6 @@
788 788  
789 789  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
790 790  
791 -
792 792  * Downlink Payload (prefix 0x0A):
793 793  
794 794  (% class="box infomessage" %)
... ... @@ -804,7 +804,6 @@
804 804  
805 805  There is no AT Command to poll uplink
806 806  
807 -
808 808  * Downlink Payload (prefix 0x08):
809 809  
810 810  (% class="box infomessage" %)
... ... @@ -831,7 +831,6 @@
831 831  
832 832  0: Disable Trigger Mode
833 833  
834 -
835 835  * Downlink Payload (prefix 0x0A 06):
836 836  
837 837  (% class="box infomessage" %)
... ... @@ -849,7 +849,6 @@
849 849  
850 850  There is no AT Command for this feature.
851 851  
852 -
853 853  * Downlink Payload (prefix 0x AB 06):
854 854  
855 855  (% class="box infomessage" %)
... ... @@ -870,7 +870,6 @@
870 870  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
871 871  )))
872 872  
873 -
874 874  **Example:**
875 875  
876 876  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -899,12 +899,10 @@
899 899  
900 900  b : delay timing.
901 901  
902 -
903 903  **Example:**
904 904  
905 905  AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms )
906 906  
907 -
908 908  * Downlink Payload (prefix 0x09 01 ):
909 909  
910 910  (% class="box infomessage" %)
... ... @@ -929,12 +929,10 @@
929 929  
930 930  b : delay timing.
931 931  
932 -
933 933  **Example:**
934 934  
935 935  AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms )
936 936  
937 -
938 938  * Downlink Payload (prefix 0x09 02 ):
939 939  
940 940  (% class="box infomessage" %)
... ... @@ -955,7 +955,6 @@
955 955  **AT+ACLIM. **
956 956  )))
957 957  
958 -
959 959  * Downlink Payload (prefix 0xAA 01 ):
960 960  
961 961  (% class="box infomessage" %)
... ... @@ -976,7 +976,6 @@
976 976  **AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
977 977  )))
978 978  
979 -
980 980  * Downlink Payload (prefix 0xAA 00 ):
981 981  
982 982  (% class="box infomessage" %)
... ... @@ -997,7 +997,6 @@
997 997  **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.**
998 998  )))
999 999  
1000 -
1001 1001  * Downlink Payload (prefix 0xAC ):
1002 1002  
1003 1003  (% class="box infomessage" %)
... ... @@ -1013,7 +1013,6 @@
1013 1013  
1014 1014  There is no AT Command to control Digital Output
1015 1015  
1016 -
1017 1017  * Downlink Payload (prefix 0x02):
1018 1018  
1019 1019  (% class="box infomessage" %)
... ... @@ -1047,7 +1047,6 @@
1047 1047  
1048 1048  There is no AT Command to control Digital Output
1049 1049  
1050 -
1051 1051  * Downlink Payload (prefix 0xA9):
1052 1052  
1053 1053  (% class="box infomessage" %)
... ... @@ -1067,22 +1067,18 @@
1067 1067  
1068 1068  00: DO pins will change to an inverter state after timeout 
1069 1069  
1070 -
1071 1071  (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status:
1072 1072  
1073 1073  [[image:image-20220524093238-6.png]]
1074 1074  
1075 -
1076 1076  (% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status:
1077 1077  
1078 1078  [[image:image-20220524093328-7.png]]
1079 1079  
1080 -
1081 1081  (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status:
1082 1082  
1083 1083  [[image:image-20220524093351-8.png]]
1084 1084  
1085 -
1086 1086  (% style="color:#4f81bd" %)**Sixth and Seventh Byte**:
1087 1087  
1088 1088   Latching time. Unit: ms
... ... @@ -1089,7 +1089,6 @@
1089 1089  
1090 1090  Device will upload a packet if downlink code executes successfully.
1091 1091  
1092 -
1093 1093  **Example payload:**
1094 1094  
1095 1095  **~1. A9 01 01 01 01 07 D0**
... ... @@ -1110,13 +1110,12 @@
1110 1110  
1111 1111  
1112 1112  
1113 -==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1088 +=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
1114 1114  
1115 1115  * AT Command:
1116 1116  
1117 1117  There is no AT Command to control Relay Output
1118 1118  
1119 -
1120 1120  * Downlink Payload (prefix 0x03):
1121 1121  
1122 1122  (% class="box infomessage" %)
... ... @@ -1146,7 +1146,6 @@
1146 1146  
1147 1147  There is no AT Command to control Relay Output
1148 1148  
1149 -
1150 1150  * Downlink Payload (prefix 0x05):
1151 1151  
1152 1152  (% class="box infomessage" %)
... ... @@ -1164,17 +1164,14 @@
1164 1164  
1165 1165  00: Relays will change to an inverter state after timeout
1166 1166  
1167 -
1168 1168  (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status:
1169 1169  
1170 1170  [[image:image-20220524093831-10.png]]
1171 1171  
1172 -
1173 1173  (% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms
1174 1174  
1175 1175  Device will upload a packet if downlink code executes successfully.
1176 1176  
1177 -
1178 1178  **Example payload:**
1179 1179  
1180 1180  **~1. 05 01 11 07 D0**
... ... @@ -1206,7 +1206,6 @@
1206 1206  **AT+VOLMAX    ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]**
1207 1207  )))
1208 1208  
1209 -
1210 1210  * Downlink Payload (prefix 0xA5):
1211 1211  
1212 1212  (% class="box infomessage" %)
... ... @@ -1233,7 +1233,6 @@
1233 1233  
1234 1234  Bb cc dd ee: number to be set
1235 1235  
1236 -
1237 1237  * Downlink Payload (prefix 0xA8):
1238 1238  
1239 1239  (% class="box infomessage" %)
... ... @@ -1286,6 +1286,7 @@
1286 1286  )))
1287 1287  
1288 1288  
1257 +
1289 1289  == 3.5 Integrate with Mydevice ==
1290 1290  
1291 1291  Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: