... ... @@ -739,8 +739,6 @@
739 739  
740 740  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
741 741  
742 -
743 -
744 744  === 3.4.1 Common Commands ===
745 745  
746 746  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -762,7 +762,6 @@
762 762  
763 763  **Example: **AT+TDC=30000. Means set interval to 30 seconds
764 764  
765 -
766 766  * Downlink Payload (prefix 0x01):
767 767  
768 768  (% class="box infomessage" %)
... ... @@ -785,7 +785,6 @@
785 785  
786 786  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
787 787  
788 -
789 789  * Downlink Payload (prefix 0x0A):
790 790  
791 791  (% class="box infomessage" %)
... ... @@ -801,7 +801,6 @@
801 801  
802 802  There is no AT Command to poll uplink
803 803  
804 -
805 805  * Downlink Payload (prefix 0x08):
806 806  
807 807  (% class="box infomessage" %)
... ... @@ -828,7 +828,6 @@
828 828  
829 829  0: Disable Trigger Mode
830 830  
831 -
832 832  * Downlink Payload (prefix 0x0A 06):
833 833  
834 834  (% class="box infomessage" %)
... ... @@ -846,7 +846,6 @@
846 846  
847 847  There is no AT Command for this feature.
848 848  
849 -
850 850  * Downlink Payload (prefix 0x AB 06):
851 851  
852 852  (% class="box infomessage" %)
... ... @@ -867,7 +867,6 @@
867 867  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
868 868  )))
869 869  
870 -
871 871  **Example:**
872 872  
873 873  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -896,12 +896,10 @@
896 896  
897 897  b : delay timing.
898 898  
899 -
900 900  **Example:**
901 901  
902 902  AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms )
903 903  
904 -
905 905  * Downlink Payload (prefix 0x09 01 ):
906 906  
907 907  (% class="box infomessage" %)
... ... @@ -926,12 +926,10 @@
926 926  
927 927  b : delay timing.
928 928  
929 -
930 930  **Example:**
931 931  
932 932  AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms )
933 933  
934 -
935 935  * Downlink Payload (prefix 0x09 02 ):
936 936  
937 937  (% class="box infomessage" %)
... ... @@ -952,7 +952,6 @@
952 952  **AT+ACLIM. **
953 953  )))
954 954  
955 -
956 956  * Downlink Payload (prefix 0xAA 01 ):
957 957  
958 958  (% class="box infomessage" %)
... ... @@ -973,7 +973,6 @@
973 973  **AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
974 974  )))
975 975  
976 -
977 977  * Downlink Payload (prefix 0xAA 00 ):
978 978  
979 979  (% class="box infomessage" %)
... ... @@ -994,7 +994,6 @@
994 994  **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.**
995 995  )))
996 996  
997 -
998 998  * Downlink Payload (prefix 0xAC ):
999 999  
1000 1000  (% class="box infomessage" %)
... ... @@ -1010,7 +1010,6 @@
1010 1010  
1011 1011  There is no AT Command to control Digital Output
1012 1012  
1013 -
1014 1014  * Downlink Payload (prefix 0x02):
1015 1015  
1016 1016  (% class="box infomessage" %)
... ... @@ -1044,7 +1044,6 @@
1044 1044  
1045 1045  There is no AT Command to control Digital Output
1046 1046  
1047 -
1048 1048  * Downlink Payload (prefix 0xA9):
1049 1049  
1050 1050  (% class="box infomessage" %)
... ... @@ -1064,22 +1064,18 @@
1064 1064  
1065 1065  00: DO pins will change to an inverter state after timeout 
1066 1066  
1067 -
1068 1068  (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status:
1069 1069  
1070 1070  [[image:image-20220524093238-6.png]]
1071 1071  
1072 -
1073 1073  (% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status:
1074 1074  
1075 1075  [[image:image-20220524093328-7.png]]
1076 1076  
1077 -
1078 1078  (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status:
1079 1079  
1080 1080  [[image:image-20220524093351-8.png]]
1081 1081  
1082 -
1083 1083  (% style="color:#4f81bd" %)**Sixth and Seventh Byte**:
1084 1084  
1085 1085   Latching time. Unit: ms
... ... @@ -1086,7 +1086,6 @@
1086 1086  
1087 1087  Device will upload a packet if downlink code executes successfully.
1088 1088  
1089 -
1090 1090  **Example payload:**
1091 1091  
1092 1092  **~1. A9 01 01 01 01 07 D0**
... ... @@ -1107,13 +1107,12 @@
1107 1107  
1108 1108  
1109 1109  
1110 -==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1088 +=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
1111 1111  
1112 1112  * AT Command:
1113 1113  
1114 1114  There is no AT Command to control Relay Output
1115 1115  
1116 -
1117 1117  * Downlink Payload (prefix 0x03):
1118 1118  
1119 1119  (% class="box infomessage" %)
... ... @@ -1143,7 +1143,6 @@
1143 1143  
1144 1144  There is no AT Command to control Relay Output
1145 1145  
1146 -
1147 1147  * Downlink Payload (prefix 0x05):
1148 1148  
1149 1149  (% class="box infomessage" %)
... ... @@ -1161,17 +1161,14 @@
1161 1161  
1162 1162  00: Relays will change to an inverter state after timeout
1163 1163  
1164 -
1165 1165  (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status:
1166 1166  
1167 1167  [[image:image-20220524093831-10.png]]
1168 1168  
1169 -
1170 1170  (% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms
1171 1171  
1172 1172  Device will upload a packet if downlink code executes successfully.
1173 1173  
1174 -
1175 1175  **Example payload:**
1176 1176  
1177 1177  **~1. 05 01 11 07 D0**
... ... @@ -1203,7 +1203,6 @@
1203 1203  **AT+VOLMAX    ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]**
1204 1204  )))
1205 1205  
1206 -
1207 1207  * Downlink Payload (prefix 0xA5):
1208 1208  
1209 1209  (% class="box infomessage" %)
... ... @@ -1230,7 +1230,6 @@
1230 1230  
1231 1231  Bb cc dd ee: number to be set
1232 1232  
1233 -
1234 1234  * Downlink Payload (prefix 0xA8):
1235 1235  
1236 1236  (% class="box infomessage" %)
... ... @@ -1283,16 +1283,17 @@
1283 1283  )))
1284 1284  
1285 1285  
1257 +
1286 1286  == 3.5 Integrate with Mydevice ==
1287 1287  
1288 1288  Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps:
1289 1289  
1290 1290  (((
1291 -(% style="color:blue" %)**Step 1**(%%): Be sure that your device is programmed and properly connected to the network at this time.
1263 +**Step 1**: Be sure that your device is programmed and properly connected to the network at this time.
1292 1292  )))
1293 1293  
1294 1294  (((
1295 -(% style="color:blue" %)**Step 2**(%%): To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps:
1267 +**Step 2**: To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps:
1296 1296  )))
1297 1297  
1298 1298  [[image:1653356737703-362.png||height="232" width="732"]]
... ... @@ -1299,13 +1299,12 @@
1299 1299  
1300 1300  [[image:image-20220524094641-11.png||height="390" width="723"]]
1301 1301  
1302 -
1303 1303  [[image:image-20220524094641-12.png||height="402" width="718"]]
1304 1304  
1305 1305  
1306 -(% style="color:blue" %)**Step 3**(%%): Create an account or log in Mydevices.
1277 +**Step 3**: Create an account or log in Mydevices.
1307 1307  
1308 -(% style="color:blue" %)**Step 4**(%%): Search LT-22222-L(for both LT-22222-L / LT-33222-L) and add DevEUI.(% style="display:none" %)
1279 +**Step 4**: Search LT-22222-L(for both LT-22222-L / LT-33222-L) and add DevEUI.(% style="display:none" %)
1309 1309  
1310 1310  Search under The things network
1311 1311  
... ... @@ -1312,21 +1312,16 @@
1312 1312  [[image:1653356838789-523.png||height="337" width="740"]]
1313 1313  
1314 1314  
1315 -
1316 1316  After added, the sensor data arrive TTN, it will also arrive and show in Mydevices.
1317 1317  
1318 1318  [[image:image-20220524094909-1.png||height="335" width="729"]]
1319 1319  
1320 -
1321 1321  [[image:image-20220524094909-2.png||height="337" width="729"]]
1322 1322  
1323 -
1324 1324  [[image:image-20220524094909-3.png||height="338" width="727"]]
1325 1325  
1326 -
1327 1327  [[image:image-20220524094909-4.png||height="339" width="728"]](% style="display:none" %)
1328 1328  
1329 -
1330 1330  [[image:image-20220524094909-5.png||height="341" width="734"]]
1331 1331  
1332 1332  
... ... @@ -1366,7 +1366,7 @@
1366 1366  )))
1367 1367  
1368 1368  (((
1369 -(% style="color:blue" %)**Example1**(%%): Connect to a Low active sensor.
1335 +**Example1**: Connect to a Low active sensor.
1370 1370  )))
1371 1371  
1372 1372  (((
... ... @@ -1397,7 +1397,7 @@
1397 1397  )))
1398 1398  
1399 1399  (((
1400 -(% style="color:blue" %)**Example2**(%%): Connect to a High active sensor.
1366 +**Example2**: Connect to a High active sensor.
1401 1401  )))
1402 1402  
1403 1403  (((
... ... @@ -1428,7 +1428,7 @@
1428 1428  )))
1429 1429  
1430 1430  (((
1431 -(% style="color:blue" %)**Example3**(%%): Connect to a 220v high active sensor.
1397 +**Example3**: Connect to a 220v high active sensor.
1432 1432  )))
1433 1433  
1434 1434  (((