Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -19,6 +19,8 @@ 19 19 == 1.1 What is LT Series I/O Controller == 20 20 21 21 ((( 22 + 23 + 22 22 The Dragino (% style="color:blue" %)**LT series I/O Modules**(%%) are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (% style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %), **relay output**, **digital input**(%%) and (% style="color:blue" %)**digital output**(%%) etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring. 23 23 ))) 24 24 ... ... @@ -48,6 +48,7 @@ 48 48 49 49 ))) 50 50 53 + 51 51 == 1.2 Specifications == 52 52 53 53 ((( ... ... @@ -76,6 +76,8 @@ 76 76 ))) 77 77 78 78 ((( 82 + 83 + 79 79 **Interface for Model: LT22222-L:** 80 80 ))) 81 81 ... ... @@ -99,6 +99,8 @@ 99 99 ))) 100 100 101 101 ((( 107 + 108 + 102 102 **LoRa Spec:** 103 103 ))) 104 104 ... ... @@ -159,6 +159,8 @@ 159 159 * ((( 160 160 Packet engine up to 256 bytes with CRC. 161 161 169 + 170 + 162 162 163 163 ))) 164 164 ... ... @@ -172,6 +172,8 @@ 172 172 * Firmware upgradable via program port 173 173 * Counting 174 174 184 + 185 + 175 175 == 1.4 Applications == 176 176 177 177 * Smart Buildings & Home Automation ... ... @@ -181,6 +181,8 @@ 181 181 * Smart Cities 182 182 * Smart Factory 183 183 195 + 196 + 184 184 == 1.5 Hardware Variants == 185 185 186 186 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -194,6 +194,7 @@ 194 194 * 1 x Counting Port 195 195 ))) 196 196 210 + 197 197 = 2. Power ON Device = 198 198 199 199 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -216,12 +216,9 @@ 216 216 217 217 ((( 218 218 In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 219 - 220 - 221 221 ))) 222 222 223 223 224 - 225 225 == 3.2 Example to join LoRaWAN network == 226 226 227 227 ((( ... ... @@ -230,12 +230,13 @@ 230 230 231 231 [[image:image-20220523172350-1.png||height="266" width="864"]] 232 232 244 + 233 233 ((( 234 234 The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN: 235 235 ))) 236 236 237 237 ((( 238 -**Step 1**: Create a device in TTN with the OTAA keys from LT IO controller. 250 +(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller. 239 239 ))) 240 240 241 241 ((( ... ... @@ -244,6 +244,7 @@ 244 244 245 245 [[image:1653297924498-393.png]] 246 246 259 + 247 247 Input these keys in the LoRaWAN Server portal. Below is TTN screen shot: 248 248 249 249 Add APP EUI in the application. ... ... @@ -257,7 +257,7 @@ 257 257 258 258 259 259 ((( 260 -**Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 273 +(% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 261 261 ))) 262 262 263 263 [[image:1653298044601-602.png||height="405" width="709"]] ... ... @@ -275,6 +275,8 @@ 275 275 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 276 276 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 277 277 291 + 292 + 278 278 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 279 279 280 280 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -282,6 +282,8 @@ 282 282 [[image:image-20220523174024-3.png]] 283 283 284 284 ((( 300 + 301 + 285 285 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 286 286 ))) 287 287 ... ... @@ -295,6 +295,7 @@ 295 295 296 296 For example if payload is: [[image:image-20220523175847-2.png]] 297 297 315 + 298 298 **The value for the interface is: ** 299 299 300 300 AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V ... ... @@ -325,8 +325,11 @@ 325 325 ** DO1 is high in case there is load between DO1 and V+. 326 326 ** DO1 LED is off in both case 327 327 346 + 347 + 328 328 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 329 329 350 + 330 330 **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins. 331 331 332 332 ((( ... ... @@ -335,6 +335,7 @@ 335 335 336 336 [[image:image-20220523180452-3.png]] 337 337 359 + 338 338 ((( 339 339 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below 340 340 ))) ... ... @@ -350,6 +350,8 @@ 350 350 ))) 351 351 352 352 ((( 375 + 376 + 353 353 **To use counting mode, please run:** 354 354 ))) 355 355 ... ... @@ -357,17 +357,14 @@ 357 357 ((( 358 358 ((( 359 359 **AT+MOD=2** 360 -))) 361 -))) 362 362 363 -(% class="box infomessage" %) 364 -((( 365 -((( 366 366 **ATZ** 367 367 ))) 368 368 ))) 369 369 370 370 ((( 390 + 391 + 371 371 (% style="color:#4f81bd" %)**AT Commands for counting:** 372 372 ))) 373 373 ... ... @@ -379,40 +379,15 @@ 379 379 ((( 380 380 ((( 381 381 **AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 382 -))) 383 -))) 384 384 385 -(% class="box infomessage" %) 386 -((( 387 -((( 388 388 **AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 389 -))) 390 -))) 391 391 392 -(% class="box infomessage" %) 393 -((( 394 -((( 395 395 **AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 396 -))) 397 -))) 398 398 399 -(% class="box infomessage" %) 400 -((( 401 -((( 402 402 **AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 403 -))) 404 -))) 405 405 406 -(% class="box infomessage" %) 407 -((( 408 -((( 409 409 **AT+SETCNT=1,60 (Set COUNT1 value to 60)** 410 -))) 411 -))) 412 412 413 -(% class="box infomessage" %) 414 -((( 415 -((( 416 416 **AT+SETCNT=2,60 (Set COUNT2 value to 60)** 417 417 ))) 418 418 ))) ... ... @@ -447,12 +447,7 @@ 447 447 ((( 448 448 ((( 449 449 **AT+MOD=3** 450 -))) 451 -))) 452 452 453 -(% class="box infomessage" %) 454 -((( 455 -((( 456 456 **ATZ** 457 457 ))) 458 458 ))) ... ... @@ -459,8 +459,6 @@ 459 459 460 460 ((( 461 461 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 462 - 463 - 464 464 ))) 465 465 466 466 ... ... @@ -467,6 +467,7 @@ 467 467 468 468 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 469 469 459 + 470 470 **LT22222-L**: This mode the DI1 is used as a counting pin. 471 471 472 472 The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour. ... ... @@ -473,6 +473,7 @@ 473 473 474 474 [[image:image-20220523181903-8.png]] 475 475 466 + 476 476 ((( 477 477 (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 478 478 ))) ... ... @@ -488,6 +488,8 @@ 488 488 ))) 489 489 490 490 ((( 482 + 483 + 491 491 **To use this mode, please run:** 492 492 ))) 493 493 ... ... @@ -495,25 +495,20 @@ 495 495 ((( 496 496 ((( 497 497 **AT+MOD=4** 498 -))) 499 -))) 500 500 501 -(% class="box infomessage" %) 502 -((( 503 -((( 504 504 **ATZ** 505 505 ))) 506 506 ))) 507 507 508 -((( 509 - 510 -))) 511 511 497 + 512 512 ((( 513 513 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 514 514 ))) 515 515 516 516 ((( 503 + 504 + 517 517 **Plus below command for AVI1 Counting:** 518 518 ))) 519 519 ... ... @@ -520,40 +520,27 @@ 520 520 (% class="box infomessage" %) 521 521 ((( 522 522 ((( 523 -**AT+SETCNT=3,60 (set AVI Count to 60)** 524 -))) 525 -))) 511 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 526 526 527 -(% class="box infomessage" %) 528 -((( 529 -((( 530 -**AT+VOLMAX=20000 (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 531 -))) 532 -))) 513 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 533 533 534 -(% class="box infomessage" %) 535 -((( 536 -((( 537 -**AT+VOLMAX=20000,0 (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 538 -))) 539 -))) 515 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 540 540 541 -(% class="box infomessage" %) 542 -((( 543 -((( 544 -**AT+VOLMAX=20000,1 (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 517 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 545 545 ))) 546 546 ))) 547 547 548 548 549 - 550 550 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 551 551 524 + 552 552 **LT22222-L**: This mode the DI1 is used as a counting pin. 553 553 554 554 [[image:image-20220523182334-9.png]] 555 555 556 556 ((( 530 + 531 + 557 557 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 558 558 ))) 559 559 ... ... @@ -568,6 +568,8 @@ 568 568 ))) 569 569 570 570 ((( 546 + 547 + 571 571 **To use this mode, please run:** 572 572 ))) 573 573 ... ... @@ -575,12 +575,7 @@ 575 575 ((( 576 576 ((( 577 577 **AT+MOD=5** 578 -))) 579 -))) 580 580 581 -(% class="box infomessage" %) 582 -((( 583 -((( 584 584 **ATZ** 585 585 ))) 586 586 ))) ... ... @@ -587,8 +587,6 @@ 587 587 588 588 ((( 589 589 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 590 - 591 - 592 592 ))) 593 593 594 594 ... ... @@ -595,6 +595,7 @@ 595 595 596 596 === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === 597 597 568 + 598 598 (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.** 599 599 600 600 For example, if user has configured below commands: ... ... @@ -607,7 +607,7 @@ 607 607 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 608 608 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 609 609 610 -**AT Command to set Trigger Condition**: 581 +(% style="color:#037691" %)**AT Command to set Trigger Condition**: 611 611 612 612 (% style="color:#4f81bd" %)**Trigger base on voltage**: 613 613 ... ... @@ -620,6 +620,7 @@ 620 620 AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 621 621 622 622 594 + 623 623 (% style="color:#4f81bd" %)**Trigger base on current**: 624 624 625 625 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> ... ... @@ -629,6 +629,7 @@ 629 629 AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) 630 630 631 631 604 + 632 632 (% style="color:#4f81bd" %)**Trigger base on DI status**: 633 633 634 634 DI status trigger Flag. ... ... @@ -635,12 +635,13 @@ 635 635 636 636 Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG > 637 637 611 + 638 638 **Example:** 639 639 640 640 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 641 641 642 642 643 -**Downlink Command to set Trigger Condition** 617 +(% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 644 644 645 645 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 646 646 ... ... @@ -658,14 +658,18 @@ 658 658 659 659 Yy4 yy4: AC2 or AV2 high limit. 660 660 635 + 661 661 **Example1**: AA 00 13 88 00 00 00 00 00 00 662 662 663 663 Same as AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 664 664 640 + 665 665 **Example2**: AA 02 01 00 666 666 667 667 Same as AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 668 668 645 + 646 + 669 669 (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:** 670 670 671 671 MOD6 Payload : total 11 bytes payload ... ... @@ -672,6 +672,7 @@ 672 672 673 673 [[image:image-20220524085923-1.png]] 674 674 653 + 675 675 (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below 676 676 677 677 [[image:image-20220524090106-2.png]] ... ... @@ -720,6 +720,8 @@ 720 720 === 3.3.7 Payload Decoder === 721 721 722 722 ((( 702 + 703 + 723 723 **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]] 724 724 725 725 ... ... @@ -726,7 +726,6 @@ 726 726 ))) 727 727 728 728 729 - 730 730 == 3.4 Configure LT via AT or Downlink == 731 731 732 732 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands ... ... @@ -740,6 +740,7 @@ 740 740 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 741 741 742 742 723 + 743 743 === 3.4.1 Common Commands === 744 744 745 745 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -752,7 +752,7 @@ 752 752 753 753 Set device uplink interval. 754 754 755 -* AT Command: 736 +* (% style="color:#037691" %)**AT Command:** 756 756 757 757 (% class="box infomessage" %) 758 758 ((( ... ... @@ -762,7 +762,7 @@ 762 762 **Example: **AT+TDC=30000. Means set interval to 30 seconds 763 763 764 764 765 -* Downlink Payload (prefix 0x01): 746 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 766 766 767 767 (% class="box infomessage" %) 768 768 ((( ... ... @@ -775,7 +775,7 @@ 775 775 776 776 Set work mode. 777 777 778 -* AT Command: 759 +* (% style="color:#037691" %)**AT Command:** 779 779 780 780 (% class="box infomessage" %) 781 781 ((( ... ... @@ -785,7 +785,7 @@ 785 785 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 786 786 787 787 788 -* Downlink Payload (prefix 0x0A): 769 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 789 789 790 790 (% class="box infomessage" %) 791 791 ((( ... ... @@ -796,12 +796,12 @@ 796 796 797 797 ==== 3.4.2.3 Poll an uplink ==== 798 798 799 -* AT Command: 780 +* (% style="color:#037691" %)AT Command: 800 800 801 801 There is no AT Command to poll uplink 802 802 803 803 804 -* Downlink Payload (prefix 0x08): 785 +* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 805 805 806 806 (% class="box infomessage" %) 807 807 ((( ... ... @@ -816,7 +816,7 @@ 816 816 817 817 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 818 818 819 -* AT Command: 800 +* (% style="color:#037691" %)AT Command: 820 820 821 821 (% class="box infomessage" %) 822 822 ((( ... ... @@ -828,7 +828,7 @@ 828 828 0: Disable Trigger Mode 829 829 830 830 831 -* Downlink Payload (prefix 0x0A 06): 812 +* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 832 832 833 833 (% class="box infomessage" %) 834 834 ((( ... ... @@ -841,12 +841,12 @@ 841 841 842 842 Poll trigger settings, 843 843 844 -* AT Command: 825 +* (% style="color:#037691" %)AT Command: 845 845 846 846 There is no AT Command for this feature. 847 847 848 848 849 -* Downlink Payload (prefix 0x AB 06): 830 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 850 850 851 851 (% class="box infomessage" %) 852 852 ((( ... ... @@ -859,7 +859,7 @@ 859 859 860 860 Enable Disable DI1/DI2/DI2 as trigger, 861 861 862 -* AT Command: 843 +* (% style="color:#037691" %)AT Command: 863 863 864 864 (% class="box infomessage" %) 865 865 ((( ... ... @@ -871,7 +871,7 @@ 871 871 872 872 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 873 873 874 -* Downlink Payload (prefix 0xAA 02): 855 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 875 875 876 876 (% class="box infomessage" %) 877 877 ((( ... ... @@ -884,7 +884,7 @@ 884 884 885 885 Set DI1 or DI3(for LT-33222-L) trigger. 886 886 887 -* AT Command: 868 +* (% style="color:#037691" %)AT Command: 888 888 889 889 (% class="box infomessage" %) 890 890 ((( ... ... @@ -901,7 +901,7 @@ 901 901 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 902 902 903 903 904 -* Downlink Payload (prefix 0x09 01 ): 885 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ): 905 905 906 906 (% class="box infomessage" %) 907 907 ((( ... ... @@ -914,7 +914,7 @@ 914 914 915 915 Set DI2 trigger. 916 916 917 -* AT Command: 898 +* (% style="color:#037691" %)AT Command: 918 918 919 919 (% class="box infomessage" %) 920 920 ((( ... ... @@ -931,7 +931,7 @@ 931 931 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 932 932 933 933 934 -* Downlink Payload (prefix 0x09 02 ): 915 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 02 ): 935 935 936 936 (% class="box infomessage" %) 937 937 ((( ... ... @@ -944,7 +944,7 @@ 944 944 945 945 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 946 946 947 -* AT Command: 928 +* (% style="color:#037691" %)AT Command: 948 948 949 949 (% class="box infomessage" %) 950 950 ((( ... ... @@ -952,7 +952,7 @@ 952 952 ))) 953 953 954 954 955 -* Downlink Payload (prefix 0xAA 01 ): 936 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 01 ): 956 956 957 957 (% class="box infomessage" %) 958 958 ((( ... ... @@ -965,7 +965,7 @@ 965 965 966 966 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 967 967 968 -* AT Command: 949 +* (% style="color:#037691" %)AT Command: 969 969 970 970 (% class="box infomessage" %) 971 971 ((( ... ... @@ -973,7 +973,7 @@ 973 973 ))) 974 974 975 975 976 -* Downlink Payload (prefix 0xAA 00 ): 957 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 00 ): 977 977 978 978 (% class="box infomessage" %) 979 979 ((( ... ... @@ -986,7 +986,7 @@ 986 986 987 987 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 988 988 989 -* AT Command: 970 +* (% style="color:#037691" %)AT Command: 990 990 991 991 (% class="box infomessage" %) 992 992 ((( ... ... @@ -994,7 +994,7 @@ 994 994 ))) 995 995 996 996 997 -* Downlink Payload (prefix 0xAC ): 978 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAC ): 998 998 999 999 (% class="box infomessage" %) 1000 1000 ((( ... ... @@ -1005,12 +1005,12 @@ 1005 1005 1006 1006 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 1007 1007 1008 -* AT Command: 989 +* (% style="color:#037691" %)AT Command: 1009 1009 1010 1010 There is no AT Command to control Digital Output 1011 1011 1012 1012 1013 -* Downlink Payload (prefix 0x02): 994 +* (% style="color:#037691" %)Downlink Payload (prefix 0x02): 1014 1014 1015 1015 (% class="box infomessage" %) 1016 1016 ((( ... ... @@ -1039,12 +1039,12 @@ 1039 1039 1040 1040 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1041 1041 1042 -* AT Command: 1023 +* (% style="color:#037691" %)AT Command: 1043 1043 1044 1044 There is no AT Command to control Digital Output 1045 1045 1046 1046 1047 -* Downlink Payload (prefix 0xA9): 1028 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA9): 1048 1048 1049 1049 (% class="box infomessage" %) 1050 1050 ((( ... ... @@ -1108,12 +1108,12 @@ 1108 1108 1109 1109 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1110 1110 1111 -* AT Command: 1092 +* (% style="color:#037691" %)AT Command: 1112 1112 1113 1113 There is no AT Command to control Relay Output 1114 1114 1115 1115 1116 -* Downlink Payload (prefix 0x03): 1097 +* (% style="color:#037691" %)Downlink Payload (prefix 0x03): 1117 1117 1118 1118 (% class="box infomessage" %) 1119 1119 ((( ... ... @@ -1138,12 +1138,12 @@ 1138 1138 1139 1139 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1140 1140 1141 -* AT Command: 1122 +* (% style="color:#037691" %)AT Command: 1142 1142 1143 1143 There is no AT Command to control Relay Output 1144 1144 1145 1145 1146 -* Downlink Payload (prefix 0x05): 1127 +* (% style="color:#037691" %)Downlink Payload (prefix 0x05): 1147 1147 1148 1148 (% class="box infomessage" %) 1149 1149 ((( ... ... @@ -1195,7 +1195,7 @@ 1195 1195 1196 1196 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1197 1197 1198 -* AT Command: 1179 +* (% style="color:#037691" %)AT Command: 1199 1199 1200 1200 (% class="box infomessage" %) 1201 1201 ((( ... ... @@ -1203,7 +1203,7 @@ 1203 1203 ))) 1204 1204 1205 1205 1206 -* Downlink Payload (prefix 0xA5): 1187 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA5): 1207 1207 1208 1208 (% class="box infomessage" %) 1209 1209 ((( ... ... @@ -1214,7 +1214,7 @@ 1214 1214 1215 1215 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1216 1216 1217 -* AT Command: 1198 +* (% style="color:#037691" %)AT Command: 1218 1218 1219 1219 (% class="box infomessage" %) 1220 1220 ((( ... ... @@ -1230,7 +1230,7 @@ 1230 1230 Bb cc dd ee: number to be set 1231 1231 1232 1232 1233 -* Downlink Payload (prefix 0xA8): 1214 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA8): 1234 1234 1235 1235 (% class="box infomessage" %) 1236 1236 ((( ... ... @@ -1243,7 +1243,7 @@ 1243 1243 1244 1244 Clear counting for counting mode 1245 1245 1246 -* AT Command: 1227 +* (% style="color:#037691" %)AT Command: 1247 1247 1248 1248 (% class="box infomessage" %) 1249 1249 ((( ... ... @@ -1250,7 +1250,7 @@ 1250 1250 **AT+CLRCOUNT ~/~/ clear all counting** 1251 1251 ))) 1252 1252 1253 -* Downlink Payload (prefix 0xA6): 1234 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA6): 1254 1254 1255 1255 (% class="box infomessage" %) 1256 1256 ((( ... ... @@ -1261,20 +1261,15 @@ 1261 1261 1262 1262 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1263 1263 1264 -* AT Command: 1245 +* (% style="color:#037691" %)**AT Command:** 1265 1265 1266 -(% class="box infomessage" %) 1267 -((( 1268 -**AT+COUTIME=60 ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)** 1269 -))) 1247 +**AT+COUTIME=60 **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) 1270 1270 1271 -* Downlink Payload (prefix 0xA7): 1272 1272 1273 -(% class="box infomessage" %) 1274 -((( 1275 -**0x A7 aa bb cc ~/~/ same as AT+COUTIME =aa bb cc,** 1276 -))) 1250 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA7):** 1277 1277 1252 +**0x A7 aa bb cc **~/~/ same as AT+COUTIME =aa bb cc, 1253 + 1278 1278 ((( 1279 1279 range: aa bb cc:0 to 16777215, (unit:second) 1280 1280 ... ... @@ -1971,8 +1971,16 @@ 1971 1971 ))) 1972 1972 1973 1973 ((( 1974 - 1950 +== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? == 1975 1975 1952 +If the device is not shut down, but directly powered off. 1953 + 1954 +It will default that this is a power-off state. 1955 + 1956 +In modes 2 to 5, DO RO status and pulse count are saved in flash. 1957 + 1958 +After restart, the status before power failure will be read from flash. 1959 + 1976 1976 = 6. Trouble Shooting = 1977 1977 ))) 1978 1978