... ... @@ -739,7 +739,6 @@
739 739  
740 740  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
741 741  
742 -
743 743  === 3.4.1 Common Commands ===
744 744  
745 745  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -761,7 +761,6 @@
761 761  
762 762  **Example: **AT+TDC=30000. Means set interval to 30 seconds
763 763  
764 -
765 765  * Downlink Payload (prefix 0x01):
766 766  
767 767  (% class="box infomessage" %)
... ... @@ -784,7 +784,6 @@
784 784  
785 785  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
786 786  
787 -
788 788  * Downlink Payload (prefix 0x0A):
789 789  
790 790  (% class="box infomessage" %)
... ... @@ -800,7 +800,6 @@
800 800  
801 801  There is no AT Command to poll uplink
802 802  
803 -
804 804  * Downlink Payload (prefix 0x08):
805 805  
806 806  (% class="box infomessage" %)
... ... @@ -827,7 +827,6 @@
827 827  
828 828  0: Disable Trigger Mode
829 829  
830 -
831 831  * Downlink Payload (prefix 0x0A 06):
832 832  
833 833  (% class="box infomessage" %)
... ... @@ -845,7 +845,6 @@
845 845  
846 846  There is no AT Command for this feature.
847 847  
848 -
849 849  * Downlink Payload (prefix 0x AB 06):
850 850  
851 851  (% class="box infomessage" %)
... ... @@ -866,7 +866,6 @@
866 866  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
867 867  )))
868 868  
869 -
870 870  **Example:**
871 871  
872 872  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -895,12 +895,10 @@
895 895  
896 896  b : delay timing.
897 897  
898 -
899 899  **Example:**
900 900  
901 901  AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms )
902 902  
903 -
904 904  * Downlink Payload (prefix 0x09 01 ):
905 905  
906 906  (% class="box infomessage" %)
... ... @@ -925,12 +925,10 @@
925 925  
926 926  b : delay timing.
927 927  
928 -
929 929  **Example:**
930 930  
931 931  AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms )
932 932  
933 -
934 934  * Downlink Payload (prefix 0x09 02 ):
935 935  
936 936  (% class="box infomessage" %)
... ... @@ -951,7 +951,6 @@
951 951  **AT+ACLIM. **
952 952  )))
953 953  
954 -
955 955  * Downlink Payload (prefix 0xAA 01 ):
956 956  
957 957  (% class="box infomessage" %)
... ... @@ -972,7 +972,6 @@
972 972  **AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
973 973  )))
974 974  
975 -
976 976  * Downlink Payload (prefix 0xAA 00 ):
977 977  
978 978  (% class="box infomessage" %)
... ... @@ -993,7 +993,6 @@
993 993  **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.**
994 994  )))
995 995  
996 -
997 997  * Downlink Payload (prefix 0xAC ):
998 998  
999 999  (% class="box infomessage" %)
... ... @@ -1009,7 +1009,6 @@
1009 1009  
1010 1010  There is no AT Command to control Digital Output
1011 1011  
1012 -
1013 1013  * Downlink Payload (prefix 0x02):
1014 1014  
1015 1015  (% class="box infomessage" %)
... ... @@ -1043,7 +1043,6 @@
1043 1043  
1044 1044  There is no AT Command to control Digital Output
1045 1045  
1046 -
1047 1047  * Downlink Payload (prefix 0xA9):
1048 1048  
1049 1049  (% class="box infomessage" %)
... ... @@ -1063,22 +1063,18 @@
1063 1063  
1064 1064  00: DO pins will change to an inverter state after timeout 
1065 1065  
1066 -
1067 1067  (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status:
1068 1068  
1069 1069  [[image:image-20220524093238-6.png]]
1070 1070  
1071 -
1072 1072  (% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status:
1073 1073  
1074 1074  [[image:image-20220524093328-7.png]]
1075 1075  
1076 -
1077 1077  (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status:
1078 1078  
1079 1079  [[image:image-20220524093351-8.png]]
1080 1080  
1081 -
1082 1082  (% style="color:#4f81bd" %)**Sixth and Seventh Byte**:
1083 1083  
1084 1084   Latching time. Unit: ms
... ... @@ -1085,7 +1085,6 @@
1085 1085  
1086 1086  Device will upload a packet if downlink code executes successfully.
1087 1087  
1088 -
1089 1089  **Example payload:**
1090 1090  
1091 1091  **~1. A9 01 01 01 01 07 D0**
... ... @@ -1106,13 +1106,12 @@
1106 1106  
1107 1107  
1108 1108  
1109 -==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1088 +=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
1110 1110  
1111 1111  * AT Command:
1112 1112  
1113 1113  There is no AT Command to control Relay Output
1114 1114  
1115 -
1116 1116  * Downlink Payload (prefix 0x03):
1117 1117  
1118 1118  (% class="box infomessage" %)
... ... @@ -1142,7 +1142,6 @@
1142 1142  
1143 1143  There is no AT Command to control Relay Output
1144 1144  
1145 -
1146 1146  * Downlink Payload (prefix 0x05):
1147 1147  
1148 1148  (% class="box infomessage" %)
... ... @@ -1160,17 +1160,14 @@
1160 1160  
1161 1161  00: Relays will change to an inverter state after timeout
1162 1162  
1163 -
1164 1164  (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status:
1165 1165  
1166 1166  [[image:image-20220524093831-10.png]]
1167 1167  
1168 -
1169 1169  (% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms
1170 1170  
1171 1171  Device will upload a packet if downlink code executes successfully.
1172 1172  
1173 -
1174 1174  **Example payload:**
1175 1175  
1176 1176  **~1. 05 01 11 07 D0**
... ... @@ -1202,7 +1202,6 @@
1202 1202  **AT+VOLMAX    ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]**
1203 1203  )))
1204 1204  
1205 -
1206 1206  * Downlink Payload (prefix 0xA5):
1207 1207  
1208 1208  (% class="box infomessage" %)
... ... @@ -1229,7 +1229,6 @@
1229 1229  
1230 1230  Bb cc dd ee: number to be set
1231 1231  
1232 -
1233 1233  * Downlink Payload (prefix 0xA8):
1234 1234  
1235 1235  (% class="box infomessage" %)
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0