740 740  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
741 741  
742 -
743 743  === 3.4.1 Common Commands ===
744 744  
745 745  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -761,7 +761,6 @@
761 761  
762 762  **Example: **AT+TDC=30000. Means set interval to 30 seconds
763 763  
764 -
765 765  * Downlink Payload (prefix 0x01):
766 766  
767 767  (% class="box infomessage" %)
... ... @@ -784,7 +784,6 @@
784 784  
785 785  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
786 786  
787 -
788 788  * Downlink Payload (prefix 0x0A):
789 789  
790 790  (% class="box infomessage" %)
... ... @@ -800,7 +800,6 @@
800 800  
801 801  There is no AT Command to poll uplink
802 802  
803 -
804 804  * Downlink Payload (prefix 0x08):
805 805  
806 806  (% class="box infomessage" %)
... ... @@ -827,7 +827,6 @@
827 827  
828 828  0: Disable Trigger Mode
829 829  
830 -
831 831  * Downlink Payload (prefix 0x0A 06):
832 832  
833 833  (% class="box infomessage" %)
... ... @@ -845,7 +845,6 @@
845 845  
846 846  There is no AT Command for this feature.
847 847  
848 -
849 849  * Downlink Payload (prefix 0x AB 06):
850 850  
851 851  (% class="box infomessage" %)
... ... @@ -866,7 +866,6 @@
866 866  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
867 867  )))
868 868  
869 -
870 870  **Example:**
871 871  
872 872  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -895,12 +895,10 @@
895 895  
896 896  b : delay timing.
897 897  
898 -
899 899  **Example:**
900 900  
901 901  AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms )
902 902  
903 -
904 904  * Downlink Payload (prefix 0x09 01 ):
905 905  
906 906  (% class="box infomessage" %)
... ... @@ -925,12 +925,10 @@
925 925  
926 926  b : delay timing.
927 927  
928 -
929 929  **Example:**
930 930  
931 931  AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms )
932 932  
933 -
934 934  * Downlink Payload (prefix 0x09 02 ):
935 935  
936 936  (% class="box infomessage" %)
... ... @@ -951,7 +951,6 @@
951 951  **AT+ACLIM. **
952 952  )))
953 953  
954 -
955 955  * Downlink Payload (prefix 0xAA 01 ):
956 956  
957 957  (% class="box infomessage" %)
... ... @@ -972,7 +972,6 @@
972 972  **AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
973 973  )))
974 974  
975 -
976 976  * Downlink Payload (prefix 0xAA 00 ):
977 977  
978 978  (% class="box infomessage" %)
... ... @@ -993,7 +993,6 @@
993 993  **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.**
994 994  )))
995 995  
996 -
997 997  * Downlink Payload (prefix 0xAC ):
998 998  
999 999  (% class="box infomessage" %)
... ... @@ -1009,7 +1009,6 @@
1009 1009  
1010 1010  There is no AT Command to control Digital Output
1011 1011  
1012 -
1013 1013  * Downlink Payload (prefix 0x02):
1014 1014  
1015 1015  (% class="box infomessage" %)
... ... @@ -1043,7 +1043,6 @@
1043 1043  
1044 1044  There is no AT Command to control Digital Output
1045 1045  
1046 -
1047 1047  * Downlink Payload (prefix 0xA9):
1048 1048  
1049 1049  (% class="box infomessage" %)
... ... @@ -1063,22 +1063,18 @@
1063 1063  
1064 1064  00: DO pins will change to an inverter state after timeout 
1065 1065  
1066 -
1067 1067  (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status:
1068 1068  
1069 1069  [[image:image-20220524093238-6.png]]
1070 1070  
1071 -
1072 1072  (% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status:
1073 1073  
1074 1074  [[image:image-20220524093328-7.png]]
1075 1075  
1076 -
1077 1077  (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status:
1078 1078  
1079 1079  [[image:image-20220524093351-8.png]]
1080 1080  
1081 -
1082 1082  (% style="color:#4f81bd" %)**Sixth and Seventh Byte**:
1083 1083  
1084 1084   Latching time. Unit: ms
... ... @@ -1085,7 +1085,6 @@
1085 1085  
1086 1086  Device will upload a packet if downlink code executes successfully.
1087 1087  
1088 -
1089 1089  **Example payload:**
1090 1090  
1091 1091  **~1. A9 01 01 01 01 07 D0**
... ... @@ -1106,13 +1106,12 @@
1106 1106  
1107 1107  
1108 1108  
1109 -==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1088 +=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
1110 1110  
1111 1111  * AT Command:
1112 1112  
1113 1113  There is no AT Command to control Relay Output
1114 1114  
1115 -
1116 1116  * Downlink Payload (prefix 0x03):
1117 1117  
1118 1118  (% class="box infomessage" %)
... ... @@ -1142,7 +1142,6 @@
1142 1142  
1143 1143  There is no AT Command to control Relay Output
1144 1144  
1145 -
1146 1146  * Downlink Payload (prefix 0x05):
1147 1147  
1148 1148  (% class="box infomessage" %)
... ... @@ -1160,17 +1160,14 @@
1160 1160  
1161 1161  00: Relays will change to an inverter state after timeout
1162 1162  
1163 -
1164 1164  (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status:
1165 1165  
1166 1166  [[image:image-20220524093831-10.png]]
1167 1167  
1168 -
1169 1169  (% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms
1170 1170  
1171 1171  Device will upload a packet if downlink code executes successfully.
1172 1172  
1173 -
1174 1174  **Example payload:**
1175 1175  
1176 1176  **~1. 05 01 11 07 D0**
... ... @@ -1202,7 +1202,6 @@
1202 1202  **AT+VOLMAX    ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]**
1203 1203  )))
1204 1204  
1205 -
1206 1206  * Downlink Payload (prefix 0xA5):
1207 1207  
1208 1208  (% class="box infomessage" %)
... ... @@ -1229,7 +1229,6 @@
1229 1229  
1230 1230  Bb cc dd ee: number to be set
1231 1231  
1232 -
1233 1233  * Downlink Payload (prefix 0xA8):
1234 1234  
1235 1235  (% class="box infomessage" %)
... ... @@ -1282,16 +1282,17 @@
1282 1282  )))
1283 1283  
1284 1284  
1257 +
1285 1285  == 3.5 Integrate with Mydevice ==
1286 1286  
1287 1287  Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps:
1288 1288  
1289 1289  (((
1290 -(% style="color:blue" %)**Step 1**(%%): Be sure that your device is programmed and properly connected to the network at this time.
1263 +**Step 1**: Be sure that your device is programmed and properly connected to the network at this time.
1291 1291  )))
1292 1292  
1293 1293  (((
1294 -(% style="color:blue" %)**Step 2**(%%): To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps:
1267 +**Step 2**: To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps:
1295 1295  )))
1296 1296  
1297 1297  [[image:1653356737703-362.png||height="232" width="732"]]
... ... @@ -1298,13 +1298,12 @@
1298 1298  
1299 1299  [[image:image-20220524094641-11.png||height="390" width="723"]]
1300 1300  
1301 -
1302 1302  [[image:image-20220524094641-12.png||height="402" width="718"]]
1303 1303  
1304 1304  
1305 -(% style="color:blue" %)**Step 3**(%%): Create an account or log in Mydevices.
1277 +**Step 3**: Create an account or log in Mydevices.
1306 1306  
1307 -(% style="color:blue" %)**Step 4**(%%): Search LT-22222-L(for both LT-22222-L / LT-33222-L) and add DevEUI.(% style="display:none" %)
1279 +**Step 4**: Search LT-22222-L(for both LT-22222-L / LT-33222-L) and add DevEUI.(% style="display:none" %)
1308 1308  
1309 1309  Search under The things network
1310 1310  
... ... @@ -1311,21 +1311,16 @@
1311 1311  [[image:1653356838789-523.png||height="337" width="740"]]
1312 1312  
1313 1313  
1314 -
1315 1315  After added, the sensor data arrive TTN, it will also arrive and show in Mydevices.
1316 1316  
1317 1317  [[image:image-20220524094909-1.png||height="335" width="729"]]
1318 1318  
1319 -
1320 1320  [[image:image-20220524094909-2.png||height="337" width="729"]]
1321 1321  
1322 -
1323 1323  [[image:image-20220524094909-3.png||height="338" width="727"]]
1324 1324  
1325 -
1326 1326  [[image:image-20220524094909-4.png||height="339" width="728"]](% style="display:none" %)
1327 1327  
1328 -
1329 1329  [[image:image-20220524094909-5.png||height="341" width="734"]]
1330 1330  
1331 1331  
... ... @@ -1365,7 +1365,7 @@
1365 1365  )))
1366 1366  
1367 1367  (((
1368 -(% style="color:blue" %)**Example1**(%%): Connect to a Low active sensor.
1335 +**Example1**: Connect to a Low active sensor.
1369 1369  )))
1370 1370  
1371 1371  (((
... ... @@ -1396,7 +1396,7 @@
1396 1396  )))
1397 1397  
1398 1398  (((
1399 -(% style="color:blue" %)**Example2**(%%): Connect to a High active sensor.
1366 +**Example2**: Connect to a High active sensor.
1400 1400  )))
1401 1401  
1402 1402  (((
... ... @@ -1427,7 +1427,7 @@
1427 1427  )))
1428 1428  
1429 1429  (((
1430 -(% style="color:blue" %)**Example3**(%%): Connect to a 220v high active sensor.
1397 +**Example3**: Connect to a 220v high active sensor.
1431 1431  )))
1432 1432  
1433 1433  (((
... ... @@ -1467,9 +1467,8 @@
1467 1467  
1468 1468  The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is:
1469 1469  
1437 +**AC2 = (IN2 voltage )/12**
1470 1470  
1471 -(% style="color:blue" %)**AC2 = (IN2 voltage )/12**
1472 -
1473 1473  [[image:1653357592296-182.png]]
1474 1474  
1475 1475  Example to connect a 4~~20mA sensor
... ... @@ -2026,6 +2026,7 @@
2026 2026  * (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865
2027 2027  * (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779
2028 2028  
1995 +
2029 2029  = 8. Packing Info =
2030 2030  
2031 2031  
... ... @@ -2043,6 +2043,7 @@
2043 2043  * Package Size / pcs : 14.5 x 8 x 5 cm
2044 2044  * Weight / pcs : 170g
2045 2045  
2013 +
2046 2046  = 9. Support =
2047 2047  
2048 2048  * (((
... ... @@ -2052,6 +2052,7 @@
2052 2052  Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
2053 2053  )))
2054 2054  
2023 +
2055 2055  = 10. Reference​​​​​ =
2056 2056  
2057 2057  * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]]