... ... @@ -602,11 +602,13 @@
602 602  * **AT+MOD=1 ** **~-~->** The normal working mode
603 603  * **AT+ADDMOD6=1**   **~-~->** Enable trigger
604 604  
605 +
605 605  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
606 606  
607 607  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
608 608  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
609 609  
611 +
610 610  **AT Command to set Trigger Condition**:
611 611  
612 612  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -658,14 +658,17 @@
658 658  
659 659   Yy4 yy4: AC2 or AV2 high limit.
660 660  
663 +
661 661  **Example1**: AA 00 13 88 00 00 00 00 00 00
662 662  
663 663  Same as AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
664 664  
668 +
665 665  **Example2**: AA 02 01 00
666 666  
667 667  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
668 668  
673 +
669 669  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
670 670  
671 671  MOD6 Payload : total 11 bytes payload
... ... @@ -672,6 +672,7 @@
672 672  
673 673  [[image:image-20220524085923-1.png]]
674 674  
680 +
675 675  (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below
676 676  
677 677  [[image:image-20220524090106-2.png]]
... ... @@ -678,6 +678,7 @@
678 678  
679 679  * Each bits shows if the corresponding trigger has been configured.
680 680  
687 +
681 681  **Example:**
682 682  
683 683  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -689,6 +689,7 @@
689 689  
690 690  * Each bits shows which status has been trigger on this uplink.
691 691  
699 +
692 692  **Example:**
693 693  
694 694  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -700,6 +700,7 @@
700 700  
701 701  * Each bits shows which status has been trigger on this uplink.
702 702  
711 +
703 703  **Example:**
704 704  
705 705  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -740,6 +740,7 @@
740 740  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
741 741  
742 742  
752 +
743 743  === 3.4.1 Common Commands ===
744 744  
745 745  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -1106,7 +1106,7 @@
1106 1106  
1107 1107  
1108 1108  
1109 -=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
1119 +==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1110 1110  
1111 1111  * AT Command:
1112 1112  