... ... @@ -19,6 +19,8 @@
19 19  == 1.1 What is LT Series I/O Controller ==
20 20  
21 21  (((
22 +
23 +
22 22  The Dragino (% style="color:blue" %)**LT series I/O Modules**(%%) are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (% style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %), **relay output**, **digital input**(%%) and (% style="color:blue" %)**digital output**(%%) etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring.
23 23  )))
24 24  
... ... @@ -48,6 +48,7 @@
48 48  
49 49  )))
50 50  
53 +
51 51  == 1.2  Specifications ==
52 52  
53 53  (((
... ... @@ -76,6 +76,8 @@
76 76  )))
77 77  
78 78  (((
82 +
83 +
79 79  **Interface for Model: LT22222-L:**
80 80  )))
81 81  
... ... @@ -99,6 +99,8 @@
99 99  )))
100 100  
101 101  (((
107 +
108 +
102 102  **LoRa Spec:**
103 103  )))
104 104  
... ... @@ -159,6 +159,8 @@
159 159  * (((
160 160  Packet engine up to 256 bytes with CRC.
161 161  
169 +
170 +
162 162  
163 163  )))
164 164  
... ... @@ -172,6 +172,8 @@
172 172  * Firmware upgradable via program port
173 173  * Counting
174 174  
184 +
185 +
175 175  == 1.4  Applications ==
176 176  
177 177  * Smart Buildings & Home Automation
... ... @@ -181,6 +181,8 @@
181 181  * Smart Cities
182 182  * Smart Factory
183 183  
195 +
196 +
184 184  == 1.5 Hardware Variants ==
185 185  
186 186  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -194,6 +194,7 @@
194 194  * 1 x Counting Port
195 195  )))
196 196  
210 +
197 197  = 2. Power ON Device =
198 198  
199 199  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -216,12 +216,9 @@
216 216  
217 217  (((
218 218  In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.
219 -
220 -
221 221  )))
222 222  
223 223  
224 -
225 225  == 3.2 Example to join LoRaWAN network ==
226 226  
227 227  (((
... ... @@ -230,12 +230,13 @@
230 230  
231 231  [[image:image-20220523172350-1.png||height="266" width="864"]]
232 232  
244 +
233 233  (((
234 234  The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN:
235 235  )))
236 236  
237 237  (((
238 -**Step 1**: Create a device in TTN with the OTAA keys from LT IO controller.
250 +(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller.
239 239  )))
240 240  
241 241  (((
... ... @@ -244,6 +244,7 @@
244 244  
245 245  [[image:1653297924498-393.png]]
246 246  
259 +
247 247  Input these keys in the LoRaWAN Server portal. Below is TTN screen shot:
248 248  
249 249  Add APP EUI in the application.
... ... @@ -257,7 +257,7 @@
257 257  
258 258  
259 259  (((
260 -**Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
273 +(% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
261 261  )))
262 262  
263 263  [[image:1653298044601-602.png||height="405" width="709"]]
... ... @@ -275,6 +275,8 @@
275 275  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
276 276  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
277 277  
291 +
292 +
278 278  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
279 279  
280 280  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -282,6 +282,8 @@
282 282  [[image:image-20220523174024-3.png]]
283 283  
284 284  (((
300 +
301 +
285 285  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
286 286  )))
287 287  
... ... @@ -295,6 +295,7 @@
295 295  
296 296  For example if payload is: [[image:image-20220523175847-2.png]]
297 297  
315 +
298 298  **The value for the interface is:  **
299 299  
300 300  AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V
... ... @@ -325,8 +325,11 @@
325 325  ** DO1 is high in case there is load between DO1 and V+.
326 326  ** DO1 LED is off in both case
327 327  
346 +
347 +
328 328  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
329 329  
350 +
330 330  **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins.
331 331  
332 332  (((
... ... @@ -335,6 +335,7 @@
335 335  
336 336  [[image:image-20220523180452-3.png]]
337 337  
359 +
338 338  (((
339 339  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below
340 340  )))
... ... @@ -350,6 +350,8 @@
350 350  )))
351 351  
352 352  (((
375 +
376 +
353 353  **To use counting mode, please run:**
354 354  )))
355 355  
... ... @@ -357,17 +357,14 @@
357 357  (((
358 358  (((
359 359  **AT+MOD=2**
360 -)))
361 -)))
362 362  
363 -(% class="box infomessage" %)
364 -(((
365 -(((
366 366  **ATZ**
367 367  )))
368 368  )))
369 369  
370 370  (((
390 +
391 +
371 371  (% style="color:#4f81bd" %)**AT Commands for counting:**
372 372  )))
373 373  
... ... @@ -379,40 +379,15 @@
379 379  (((
380 380  (((
381 381  **AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) **
382 -)))
383 -)))
384 384  
385 -(% class="box infomessage" %)
386 -(((
387 -(((
388 388  **AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) **
389 -)))
390 -)))
391 391  
392 -(% class="box infomessage" %)
393 -(((
394 -(((
395 395  **AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) **
396 -)))
397 -)))
398 398  
399 -(% class="box infomessage" %)
400 -(((
401 -(((
402 402  **AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) **
403 -)))
404 -)))
405 405  
406 -(% class="box infomessage" %)
407 -(((
408 -(((
409 409  **AT+SETCNT=1,60   (Set COUNT1 value to 60)**
410 -)))
411 -)))
412 412  
413 -(% class="box infomessage" %)
414 -(((
415 -(((
416 416  **AT+SETCNT=2,60   (Set COUNT2 value to 60)**
417 417  )))
418 418  )))
... ... @@ -447,12 +447,7 @@
447 447  (((
448 448  (((
449 449  **AT+MOD=3**
450 -)))
451 -)))
452 452  
453 -(% class="box infomessage" %)
454 -(((
455 -(((
456 456  **ATZ**
457 457  )))
458 458  )))
... ... @@ -459,8 +459,6 @@
459 459  
460 460  (((
461 461  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
462 -
463 -
464 464  )))
465 465  
466 466  
... ... @@ -467,6 +467,7 @@
467 467  
468 468  === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting ===
469 469  
459 +
470 470  **LT22222-L**: This mode the DI1 is used as a counting pin.
471 471  
472 472  The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour.
... ... @@ -473,6 +473,7 @@
473 473  
474 474  [[image:image-20220523181903-8.png]]
475 475  
466 +
476 476  (((
477 477  (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
478 478  )))
... ... @@ -488,6 +488,8 @@
488 488  )))
489 489  
490 490  (((
482 +
483 +
491 491  **To use this mode, please run:**
492 492  )))
493 493  
... ... @@ -495,25 +495,20 @@
495 495  (((
496 496  (((
497 497  **AT+MOD=4**
498 -)))
499 -)))
500 500  
501 -(% class="box infomessage" %)
502 -(((
503 -(((
504 504  **ATZ**
505 505  )))
506 506  )))
507 507  
508 -(((
509 -
510 -)))
511 511  
497 +
512 512  (((
513 513  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
514 514  )))
515 515  
516 516  (((
503 +
504 +
517 517  **Plus below command for AVI1 Counting:**
518 518  )))
519 519  
... ... @@ -520,40 +520,27 @@
520 520  (% class="box infomessage" %)
521 521  (((
522 522  (((
523 -**AT+SETCNT=3,60   (set AVI Count to 60)**
524 -)))
525 -)))
511 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)**   (set AVI Count to 60)**
526 526  
527 -(% class="box infomessage" %)
528 -(((
529 -(((
530 -**AT+VOLMAX=20000   (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)**
531 -)))
532 -)))
513 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)**   (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)**
533 533  
534 -(% class="box infomessage" %)
535 -(((
536 -(((
537 -**AT+VOLMAX=20000,0   (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)**
538 -)))
539 -)))
515 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)**   (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)**
540 540  
541 -(% class="box infomessage" %)
542 -(((
543 -(((
544 -**AT+VOLMAX=20000,1   (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)**
517 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)**   (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)**
545 545  )))
546 546  )))
547 547  
548 548  
549 -
550 550  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
551 551  
524 +
552 552  **LT22222-L**: This mode the DI1 is used as a counting pin.
553 553  
554 554  [[image:image-20220523182334-9.png]]
555 555  
556 556  (((
530 +
531 +
557 557  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
558 558  )))
559 559  
... ... @@ -568,6 +568,8 @@
568 568  )))
569 569  
570 570  (((
546 +
547 +
571 571  **To use this mode, please run:**
572 572  )))
573 573  
... ... @@ -575,12 +575,7 @@
575 575  (((
576 576  (((
577 577  **AT+MOD=5**
578 -)))
579 -)))
580 580  
581 -(% class="box infomessage" %)
582 -(((
583 -(((
584 584  **ATZ**
585 585  )))
586 586  )))
... ... @@ -587,8 +587,6 @@
587 587  
588 588  (((
589 589  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
590 -
591 -
592 592  )))
593 593  
594 594  
... ... @@ -595,6 +595,7 @@
595 595  
596 596  === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) ===
597 597  
568 +
598 598  (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.**
599 599  
600 600  For example, if user has configured below commands:
... ... @@ -607,7 +607,7 @@
607 607  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
608 608  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
609 609  
610 -**AT Command to set Trigger Condition**:
581 +(% style="color:#037691" %)**AT Command to set Trigger Condition**:
611 611  
612 612  (% style="color:#4f81bd" %)**Trigger base on voltage**:
613 613  
... ... @@ -620,6 +620,7 @@
620 620  AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
621 621  
622 622  
594 +
623 623  (% style="color:#4f81bd" %)**Trigger base on current**:
624 624  
625 625  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
... ... @@ -629,6 +629,7 @@
629 629  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
630 630  
631 631  
604 +
632 632  (% style="color:#4f81bd" %)**Trigger base on DI status**:
633 633  
634 634  DI status trigger Flag.
... ... @@ -635,12 +635,13 @@
635 635  
636 636  Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >
637 637  
611 +
638 638  **Example:**
639 639  
640 640  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
641 641  
642 642  
643 -**Downlink Command to set Trigger Condition**
617 +(% style="color:#037691" %)**Downlink Command to set Trigger Condition:**
644 644  
645 645  Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM**
646 646  
... ... @@ -658,14 +658,18 @@
658 658  
659 659   Yy4 yy4: AC2 or AV2 high limit.
660 660  
635 +
661 661  **Example1**: AA 00 13 88 00 00 00 00 00 00
662 662  
663 663  Same as AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
664 664  
640 +
665 665  **Example2**: AA 02 01 00
666 666  
667 667  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
668 668  
645 +
646 +
669 669  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
670 670  
671 671  MOD6 Payload : total 11 bytes payload
... ... @@ -672,6 +672,7 @@
672 672  
673 673  [[image:image-20220524085923-1.png]]
674 674  
653 +
675 675  (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below
676 676  
677 677  [[image:image-20220524090106-2.png]]
... ... @@ -720,6 +720,8 @@
720 720  === 3.3.7 Payload Decoder ===
721 721  
722 722  (((
702 +
703 +
723 723  **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]]
724 724  
725 725  
... ... @@ -726,7 +726,6 @@
726 726  )))
727 727  
728 728  
729 -
730 730  == 3.4 ​Configure LT via AT or Downlink ==
731 731  
732 732  User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands
... ... @@ -739,6 +739,8 @@
739 739  
740 740  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
741 741  
722 +
723 +
742 742  === 3.4.1 Common Commands ===
743 743  
744 744  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -751,7 +751,7 @@
751 751  
752 752  Set device uplink interval.
753 753  
754 -* AT Command:
736 +* (% style="color:#037691" %)**AT Command:**
755 755  
756 756  (% class="box infomessage" %)
757 757  (((
... ... @@ -761,7 +761,7 @@
761 761  **Example: **AT+TDC=30000. Means set interval to 30 seconds
762 762  
763 763  
764 -* Downlink Payload (prefix 0x01):
746 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x01):**
765 765  
766 766  (% class="box infomessage" %)
767 767  (((
... ... @@ -774,7 +774,7 @@
774 774  
775 775  Set work mode.
776 776  
777 -* AT Command:
759 +* (% style="color:#037691" %)**AT Command:**
778 778  
779 779  (% class="box infomessage" %)
780 780  (((
... ... @@ -784,7 +784,7 @@
784 784  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
785 785  
786 786  
787 -* Downlink Payload (prefix 0x0A):
769 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):**
788 788  
789 789  (% class="box infomessage" %)
790 790  (((
... ... @@ -795,12 +795,12 @@
795 795  
796 796  ==== 3.4.2.3 Poll an uplink ====
797 797  
798 -* AT Command:
780 +* (% style="color:#037691" %)AT Command:
799 799  
800 800  There is no AT Command to poll uplink
801 801  
802 802  
803 -* Downlink Payload (prefix 0x08):
785 +* (% style="color:#037691" %)Downlink Payload (prefix 0x08):
804 804  
805 805  (% class="box infomessage" %)
806 806  (((
... ... @@ -815,7 +815,7 @@
815 815  
816 816  Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
817 817  
818 -* AT Command:
800 +* (% style="color:#037691" %)AT Command:
819 819  
820 820  (% class="box infomessage" %)
821 821  (((
... ... @@ -827,7 +827,7 @@
827 827  0: Disable Trigger Mode
828 828  
829 829  
830 -* Downlink Payload (prefix 0x0A 06):
812 +* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06):
831 831  
832 832  (% class="box infomessage" %)
833 833  (((
... ... @@ -840,12 +840,12 @@
840 840  
841 841  Poll trigger settings,
842 842  
843 -* AT Command:
825 +* (% style="color:#037691" %)AT Command:
844 844  
845 845  There is no AT Command for this feature.
846 846  
847 847  
848 -* Downlink Payload (prefix 0x AB 06):
830 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06):
849 849  
850 850  (% class="box infomessage" %)
851 851  (((
... ... @@ -858,7 +858,7 @@
858 858  
859 859  Enable Disable DI1/DI2/DI2 as trigger,
860 860  
861 -* AT Command:
843 +* (% style="color:#037691" %)AT Command:
862 862  
863 863  (% class="box infomessage" %)
864 864  (((
... ... @@ -870,7 +870,7 @@
870 870  
871 871  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
872 872  
873 -* Downlink Payload (prefix 0xAA 02):
855 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02):
874 874  
875 875  (% class="box infomessage" %)
876 876  (((
... ... @@ -883,7 +883,7 @@
883 883  
884 884  Set DI1 or DI3(for LT-33222-L) trigger.
885 885  
886 -* AT Command:
868 +* (% style="color:#037691" %)AT Command:
887 887  
888 888  (% class="box infomessage" %)
889 889  (((
... ... @@ -900,7 +900,7 @@
900 900  AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms )
901 901  
902 902  
903 -* Downlink Payload (prefix 0x09 01 ):
885 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ):
904 904  
905 905  (% class="box infomessage" %)
906 906  (((
... ... @@ -913,7 +913,7 @@
913 913  
914 914  Set DI2 trigger.
915 915  
916 -* AT Command:
898 +* (% style="color:#037691" %)AT Command:
917 917  
918 918  (% class="box infomessage" %)
919 919  (((
... ... @@ -930,7 +930,7 @@
930 930  AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms )
931 931  
932 932  
933 -* Downlink Payload (prefix 0x09 02 ):
915 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 02 ):
934 934  
935 935  (% class="box infomessage" %)
936 936  (((
... ... @@ -943,7 +943,7 @@
943 943  
944 944  Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
945 945  
946 -* AT Command:
928 +* (% style="color:#037691" %)AT Command:
947 947  
948 948  (% class="box infomessage" %)
949 949  (((
... ... @@ -951,7 +951,7 @@
951 951  )))
952 952  
953 953  
954 -* Downlink Payload (prefix 0xAA 01 ):
936 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 01 ):
955 955  
956 956  (% class="box infomessage" %)
957 957  (((
... ... @@ -964,7 +964,7 @@
964 964  
965 965  Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
966 966  
967 -* AT Command:
949 +* (% style="color:#037691" %)AT Command:
968 968  
969 969  (% class="box infomessage" %)
970 970  (((
... ... @@ -972,7 +972,7 @@
972 972  )))
973 973  
974 974  
975 -* Downlink Payload (prefix 0xAA 00 ):
957 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 00 ):
976 976  
977 977  (% class="box infomessage" %)
978 978  (((
... ... @@ -985,7 +985,7 @@
985 985  
986 986  Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger.
987 987  
988 -* AT Command:
970 +* (% style="color:#037691" %)AT Command:
989 989  
990 990  (% class="box infomessage" %)
991 991  (((
... ... @@ -993,7 +993,7 @@
993 993  )))
994 994  
995 995  
996 -* Downlink Payload (prefix 0xAC ):
978 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAC ):
997 997  
998 998  (% class="box infomessage" %)
999 999  (((
... ... @@ -1004,12 +1004,12 @@
1004 1004  
1005 1005  ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ====
1006 1006  
1007 -* AT Command:
989 +* (% style="color:#037691" %)AT Command:
1008 1008  
1009 1009  There is no AT Command to control Digital Output
1010 1010  
1011 1011  
1012 -* Downlink Payload (prefix 0x02):
994 +* (% style="color:#037691" %)Downlink Payload (prefix 0x02):
1013 1013  
1014 1014  (% class="box infomessage" %)
1015 1015  (((
... ... @@ -1038,12 +1038,12 @@
1038 1038  
1039 1039  ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ====
1040 1040  
1041 -* AT Command:
1023 +* (% style="color:#037691" %)AT Command:
1042 1042  
1043 1043  There is no AT Command to control Digital Output
1044 1044  
1045 1045  
1046 -* Downlink Payload (prefix 0xA9):
1028 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA9):
1047 1047  
1048 1048  (% class="box infomessage" %)
1049 1049  (((
... ... @@ -1105,14 +1105,14 @@
1105 1105  
1106 1106  
1107 1107  
1108 -=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
1090 +==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1109 1109  
1110 -* AT Command:
1092 +* (% style="color:#037691" %)AT Command:
1111 1111  
1112 1112  There is no AT Command to control Relay Output
1113 1113  
1114 1114  
1115 -* Downlink Payload (prefix 0x03):
1097 +* (% style="color:#037691" %)Downlink Payload (prefix 0x03):
1116 1116  
1117 1117  (% class="box infomessage" %)
1118 1118  (((
... ... @@ -1137,12 +1137,12 @@
1137 1137  
1138 1138  ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ====
1139 1139  
1140 -* AT Command:
1122 +* (% style="color:#037691" %)AT Command:
1141 1141  
1142 1142  There is no AT Command to control Relay Output
1143 1143  
1144 1144  
1145 -* Downlink Payload (prefix 0x05):
1127 +* (% style="color:#037691" %)Downlink Payload (prefix 0x05):
1146 1146  
1147 1147  (% class="box infomessage" %)
1148 1148  (((
... ... @@ -1194,7 +1194,7 @@
1194 1194  
1195 1195  When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1196 1196  
1197 -* AT Command:
1179 +* (% style="color:#037691" %)AT Command:
1198 1198  
1199 1199  (% class="box infomessage" %)
1200 1200  (((
... ... @@ -1202,7 +1202,7 @@
1202 1202  )))
1203 1203  
1204 1204  
1205 -* Downlink Payload (prefix 0xA5):
1187 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA5):
1206 1206  
1207 1207  (% class="box infomessage" %)
1208 1208  (((
... ... @@ -1213,7 +1213,7 @@
1213 1213  
1214 1214  ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ====
1215 1215  
1216 -* AT Command:
1198 +* (% style="color:#037691" %)AT Command:
1217 1217  
1218 1218  (% class="box infomessage" %)
1219 1219  (((
... ... @@ -1229,7 +1229,7 @@
1229 1229  Bb cc dd ee: number to be set
1230 1230  
1231 1231  
1232 -* Downlink Payload (prefix 0xA8):
1214 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA8):
1233 1233  
1234 1234  (% class="box infomessage" %)
1235 1235  (((
... ... @@ -1242,7 +1242,7 @@
1242 1242  
1243 1243  Clear counting for counting mode
1244 1244  
1245 -* AT Command:
1227 +* (% style="color:#037691" %)AT Command:
1246 1246  
1247 1247  (% class="box infomessage" %)
1248 1248  (((
... ... @@ -1249,7 +1249,7 @@
1249 1249  **AT+CLRCOUNT ~/~/ clear all counting**
1250 1250  )))
1251 1251  
1252 -* Downlink Payload (prefix 0xA6):
1234 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA6):
1253 1253  
1254 1254  (% class="box infomessage" %)
1255 1255  (((
... ... @@ -1260,7 +1260,7 @@
1260 1260  
1261 1261  ==== 3.4.2.19 Counting ~-~- Change counting mode save time ====
1262 1262  
1263 -* AT Command:
1245 +* (% style="color:#037691" %)AT Command:
1264 1264  
1265 1265  (% class="box infomessage" %)
1266 1266  (((
... ... @@ -1267,7 +1267,7 @@
1267 1267  **AT+COUTIME=60  ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)**
1268 1268  )))
1269 1269  
1270 -* Downlink Payload (prefix 0xA7):
1252 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA7):
1271 1271  
1272 1272  (% class="box infomessage" %)
1273 1273  (((
... ... @@ -1970,8 +1970,16 @@
1970 1970  )))
1971 1971  
1972 1972  (((
1973 -
1955 +== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? ==
1974 1974  
1957 +If the device is not shut down, but directly powered off.
1958 +
1959 +It will default that this is a power-off state.
1960 +
1961 +In modes 2 to 5, DO RO status and pulse count are saved in flash.
1962 +
1963 +After restart, the status before power failure will be read from flash.
1964 +
1975 1975  = 6. Trouble Shooting =
1976 1976  )))
1977 1977