Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -19,6 +19,8 @@ 19 19 == 1.1 What is LT Series I/O Controller == 20 20 21 21 ((( 22 + 23 + 22 22 The Dragino (% style="color:blue" %)**LT series I/O Modules**(%%) are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (% style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %), **relay output**, **digital input**(%%) and (% style="color:blue" %)**digital output**(%%) etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring. 23 23 ))) 24 24 ... ... @@ -48,6 +48,7 @@ 48 48 49 49 ))) 50 50 53 + 51 51 == 1.2 Specifications == 52 52 53 53 ((( ... ... @@ -76,6 +76,8 @@ 76 76 ))) 77 77 78 78 ((( 82 + 83 + 79 79 **Interface for Model: LT22222-L:** 80 80 ))) 81 81 ... ... @@ -99,6 +99,8 @@ 99 99 ))) 100 100 101 101 ((( 107 + 108 + 102 102 **LoRa Spec:** 103 103 ))) 104 104 ... ... @@ -159,6 +159,8 @@ 159 159 * ((( 160 160 Packet engine up to 256 bytes with CRC. 161 161 169 + 170 + 162 162 163 163 ))) 164 164 ... ... @@ -172,6 +172,8 @@ 172 172 * Firmware upgradable via program port 173 173 * Counting 174 174 184 + 185 + 175 175 == 1.4 Applications == 176 176 177 177 * Smart Buildings & Home Automation ... ... @@ -181,6 +181,8 @@ 181 181 * Smart Cities 182 182 * Smart Factory 183 183 195 + 196 + 184 184 == 1.5 Hardware Variants == 185 185 186 186 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -194,6 +194,7 @@ 194 194 * 1 x Counting Port 195 195 ))) 196 196 210 + 197 197 = 2. Power ON Device = 198 198 199 199 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -216,12 +216,9 @@ 216 216 217 217 ((( 218 218 In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 219 - 220 - 221 221 ))) 222 222 223 223 224 - 225 225 == 3.2 Example to join LoRaWAN network == 226 226 227 227 ((( ... ... @@ -230,12 +230,13 @@ 230 230 231 231 [[image:image-20220523172350-1.png||height="266" width="864"]] 232 232 244 + 233 233 ((( 234 234 The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN: 235 235 ))) 236 236 237 237 ((( 238 -**Step 1**: Create a device in TTN with the OTAA keys from LT IO controller. 250 +(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller. 239 239 ))) 240 240 241 241 ((( ... ... @@ -244,6 +244,7 @@ 244 244 245 245 [[image:1653297924498-393.png]] 246 246 259 + 247 247 Input these keys in the LoRaWAN Server portal. Below is TTN screen shot: 248 248 249 249 Add APP EUI in the application. ... ... @@ -257,7 +257,7 @@ 257 257 258 258 259 259 ((( 260 -**Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 273 +(% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 261 261 ))) 262 262 263 263 [[image:1653298044601-602.png||height="405" width="709"]] ... ... @@ -275,6 +275,8 @@ 275 275 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 276 276 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 277 277 291 + 292 + 278 278 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 279 279 280 280 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -282,6 +282,8 @@ 282 282 [[image:image-20220523174024-3.png]] 283 283 284 284 ((( 300 + 301 + 285 285 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 286 286 ))) 287 287 ... ... @@ -295,6 +295,7 @@ 295 295 296 296 For example if payload is: [[image:image-20220523175847-2.png]] 297 297 315 + 298 298 **The value for the interface is: ** 299 299 300 300 AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V ... ... @@ -325,8 +325,11 @@ 325 325 ** DO1 is high in case there is load between DO1 and V+. 326 326 ** DO1 LED is off in both case 327 327 346 + 347 + 328 328 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 329 329 350 + 330 330 **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins. 331 331 332 332 ((( ... ... @@ -335,6 +335,7 @@ 335 335 336 336 [[image:image-20220523180452-3.png]] 337 337 359 + 338 338 ((( 339 339 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below 340 340 ))) ... ... @@ -350,6 +350,8 @@ 350 350 ))) 351 351 352 352 ((( 375 + 376 + 353 353 **To use counting mode, please run:** 354 354 ))) 355 355 ... ... @@ -357,17 +357,14 @@ 357 357 ((( 358 358 ((( 359 359 **AT+MOD=2** 360 -))) 361 -))) 362 362 363 -(% class="box infomessage" %) 364 -((( 365 -((( 366 366 **ATZ** 367 367 ))) 368 368 ))) 369 369 370 370 ((( 390 + 391 + 371 371 (% style="color:#4f81bd" %)**AT Commands for counting:** 372 372 ))) 373 373 ... ... @@ -379,40 +379,15 @@ 379 379 ((( 380 380 ((( 381 381 **AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 382 -))) 383 -))) 384 384 385 -(% class="box infomessage" %) 386 -((( 387 -((( 388 388 **AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 389 -))) 390 -))) 391 391 392 -(% class="box infomessage" %) 393 -((( 394 -((( 395 395 **AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 396 -))) 397 -))) 398 398 399 -(% class="box infomessage" %) 400 -((( 401 -((( 402 402 **AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 403 -))) 404 -))) 405 405 406 -(% class="box infomessage" %) 407 -((( 408 -((( 409 409 **AT+SETCNT=1,60 (Set COUNT1 value to 60)** 410 -))) 411 -))) 412 412 413 -(% class="box infomessage" %) 414 -((( 415 -((( 416 416 **AT+SETCNT=2,60 (Set COUNT2 value to 60)** 417 417 ))) 418 418 ))) ... ... @@ -447,12 +447,7 @@ 447 447 ((( 448 448 ((( 449 449 **AT+MOD=3** 450 -))) 451 -))) 452 452 453 -(% class="box infomessage" %) 454 -((( 455 -((( 456 456 **ATZ** 457 457 ))) 458 458 ))) ... ... @@ -459,8 +459,6 @@ 459 459 460 460 ((( 461 461 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 462 - 463 - 464 464 ))) 465 465 466 466 ... ... @@ -467,6 +467,7 @@ 467 467 468 468 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 469 469 459 + 470 470 **LT22222-L**: This mode the DI1 is used as a counting pin. 471 471 472 472 The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour. ... ... @@ -473,6 +473,7 @@ 473 473 474 474 [[image:image-20220523181903-8.png]] 475 475 466 + 476 476 ((( 477 477 (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 478 478 ))) ... ... @@ -488,6 +488,8 @@ 488 488 ))) 489 489 490 490 ((( 482 + 483 + 491 491 **To use this mode, please run:** 492 492 ))) 493 493 ... ... @@ -495,25 +495,20 @@ 495 495 ((( 496 496 ((( 497 497 **AT+MOD=4** 498 -))) 499 -))) 500 500 501 -(% class="box infomessage" %) 502 -((( 503 -((( 504 504 **ATZ** 505 505 ))) 506 506 ))) 507 507 508 -((( 509 - 510 -))) 511 511 497 + 512 512 ((( 513 513 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 514 514 ))) 515 515 516 516 ((( 503 + 504 + 517 517 **Plus below command for AVI1 Counting:** 518 518 ))) 519 519 ... ... @@ -520,40 +520,27 @@ 520 520 (% class="box infomessage" %) 521 521 ((( 522 522 ((( 523 -**AT+SETCNT=3,60 (set AVI Count to 60)** 524 -))) 525 -))) 511 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 526 526 527 -(% class="box infomessage" %) 528 -((( 529 -((( 530 -**AT+VOLMAX=20000 (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 531 -))) 532 -))) 513 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 533 533 534 -(% class="box infomessage" %) 535 -((( 536 -((( 537 -**AT+VOLMAX=20000,0 (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 538 -))) 539 -))) 515 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 540 540 541 -(% class="box infomessage" %) 542 -((( 543 -((( 544 -**AT+VOLMAX=20000,1 (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 517 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 545 545 ))) 546 546 ))) 547 547 548 548 549 - 550 550 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 551 551 524 + 552 552 **LT22222-L**: This mode the DI1 is used as a counting pin. 553 553 554 554 [[image:image-20220523182334-9.png]] 555 555 556 556 ((( 530 + 531 + 557 557 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 558 558 ))) 559 559 ... ... @@ -568,6 +568,8 @@ 568 568 ))) 569 569 570 570 ((( 546 + 547 + 571 571 **To use this mode, please run:** 572 572 ))) 573 573 ... ... @@ -575,12 +575,7 @@ 575 575 ((( 576 576 ((( 577 577 **AT+MOD=5** 578 -))) 579 -))) 580 580 581 -(% class="box infomessage" %) 582 -((( 583 -((( 584 584 **ATZ** 585 585 ))) 586 586 ))) ... ... @@ -587,8 +587,6 @@ 587 587 588 588 ((( 589 589 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 590 - 591 - 592 592 ))) 593 593 594 594 ... ... @@ -595,6 +595,7 @@ 595 595 596 596 === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === 597 597 568 + 598 598 (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.** 599 599 600 600 For example, if user has configured below commands: ... ... @@ -607,7 +607,7 @@ 607 607 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 608 608 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 609 609 610 -**AT Command to set Trigger Condition**: 581 +(% style="color:#037691" %)**AT Command to set Trigger Condition**: 611 611 612 612 (% style="color:#4f81bd" %)**Trigger base on voltage**: 613 613 ... ... @@ -620,6 +620,7 @@ 620 620 AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 621 621 622 622 594 + 623 623 (% style="color:#4f81bd" %)**Trigger base on current**: 624 624 625 625 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> ... ... @@ -629,6 +629,7 @@ 629 629 AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) 630 630 631 631 604 + 632 632 (% style="color:#4f81bd" %)**Trigger base on DI status**: 633 633 634 634 DI status trigger Flag. ... ... @@ -635,12 +635,13 @@ 635 635 636 636 Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG > 637 637 611 + 638 638 **Example:** 639 639 640 640 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 641 641 642 642 643 -**Downlink Command to set Trigger Condition** 617 +(% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 644 644 645 645 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 646 646 ... ... @@ -658,14 +658,18 @@ 658 658 659 659 Yy4 yy4: AC2 or AV2 high limit. 660 660 635 + 661 661 **Example1**: AA 00 13 88 00 00 00 00 00 00 662 662 663 663 Same as AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 664 664 640 + 665 665 **Example2**: AA 02 01 00 666 666 667 667 Same as AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 668 668 645 + 646 + 669 669 (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:** 670 670 671 671 MOD6 Payload : total 11 bytes payload ... ... @@ -672,6 +672,7 @@ 672 672 673 673 [[image:image-20220524085923-1.png]] 674 674 653 + 675 675 (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below 676 676 677 677 [[image:image-20220524090106-2.png]] ... ... @@ -720,6 +720,8 @@ 720 720 === 3.3.7 Payload Decoder === 721 721 722 722 ((( 702 + 703 + 723 723 **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]] 724 724 725 725 ... ... @@ -726,7 +726,6 @@ 726 726 ))) 727 727 728 728 729 - 730 730 == 3.4 Configure LT via AT or Downlink == 731 731 732 732 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands ... ... @@ -739,6 +739,8 @@ 739 739 740 740 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 741 741 722 + 723 + 742 742 === 3.4.1 Common Commands === 743 743 744 744 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -751,7 +751,7 @@ 751 751 752 752 Set device uplink interval. 753 753 754 -* AT Command: 736 +* (% style="color:#037691" %)**AT Command:** 755 755 756 756 (% class="box infomessage" %) 757 757 ((( ... ... @@ -760,8 +760,9 @@ 760 760 761 761 **Example: **AT+TDC=30000. Means set interval to 30 seconds 762 762 763 -* Downlink Payload (prefix 0x01): 764 764 746 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 747 + 765 765 (% class="box infomessage" %) 766 766 ((( 767 767 **0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** ... ... @@ -773,7 +773,7 @@ 773 773 774 774 Set work mode. 775 775 776 -* AT Command: 759 +* (% style="color:#037691" %)**AT Command:** 777 777 778 778 (% class="box infomessage" %) 779 779 ((( ... ... @@ -782,8 +782,9 @@ 782 782 783 783 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 784 784 785 -* Downlink Payload (prefix 0x0A): 786 786 769 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 770 + 787 787 (% class="box infomessage" %) 788 788 ((( 789 789 **0x0A aa ~/~/ Same as AT+MOD=aa** ... ... @@ -793,12 +793,13 @@ 793 793 794 794 ==== 3.4.2.3 Poll an uplink ==== 795 795 796 -* AT Command: 780 +* (% style="color:#037691" %)AT Command: 797 797 798 798 There is no AT Command to poll uplink 799 799 800 -* Downlink Payload (prefix 0x08): 801 801 785 +* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 786 + 802 802 (% class="box infomessage" %) 803 803 ((( 804 804 **0x08 FF ~/~/ Poll an uplink,** ... ... @@ -812,7 +812,7 @@ 812 812 813 813 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 814 814 815 -* AT Command: 800 +* (% style="color:#037691" %)AT Command: 816 816 817 817 (% class="box infomessage" %) 818 818 ((( ... ... @@ -823,8 +823,9 @@ 823 823 824 824 0: Disable Trigger Mode 825 825 826 -* Downlink Payload (prefix 0x0A 06): 827 827 812 +* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 813 + 828 828 (% class="box infomessage" %) 829 829 ((( 830 830 **0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** ... ... @@ -836,12 +836,13 @@ 836 836 837 837 Poll trigger settings, 838 838 839 -* AT Command: 825 +* (% style="color:#037691" %)AT Command: 840 840 841 841 There is no AT Command for this feature. 842 842 843 -* Downlink Payload (prefix 0x AB 06): 844 844 830 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 831 + 845 845 (% class="box infomessage" %) 846 846 ((( 847 847 **0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** ... ... @@ -853,7 +853,7 @@ 853 853 854 854 Enable Disable DI1/DI2/DI2 as trigger, 855 855 856 -* AT Command: 843 +* (% style="color:#037691" %)AT Command: 857 857 858 858 (% class="box infomessage" %) 859 859 ((( ... ... @@ -860,11 +860,12 @@ 860 860 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 861 861 ))) 862 862 850 + 863 863 **Example:** 864 864 865 865 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 866 866 867 -* Downlink Payload (prefix 0xAA 02): 855 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 868 868 869 869 (% class="box infomessage" %) 870 870 ((( ... ... @@ -877,7 +877,7 @@ 877 877 878 878 Set DI1 or DI3(for LT-33222-L) trigger. 879 879 880 -* AT Command: 868 +* (% style="color:#037691" %)AT Command: 881 881 882 882 (% class="box infomessage" %) 883 883 ((( ... ... @@ -894,7 +894,7 @@ 894 894 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 895 895 896 896 897 -* Downlink Payload (prefix 0x09 01 ): 885 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ): 898 898 899 899 (% class="box infomessage" %) 900 900 ((( ... ... @@ -907,7 +907,7 @@ 907 907 908 908 Set DI2 trigger. 909 909 910 -* AT Command: 898 +* (% style="color:#037691" %)AT Command: 911 911 912 912 (% class="box infomessage" %) 913 913 ((( ... ... @@ -924,7 +924,7 @@ 924 924 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 925 925 926 926 927 -* Downlink Payload (prefix 0x09 02 ): 915 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 02 ): 928 928 929 929 (% class="box infomessage" %) 930 930 ((( ... ... @@ -937,7 +937,7 @@ 937 937 938 938 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 939 939 940 -* AT Command: 928 +* (% style="color:#037691" %)AT Command: 941 941 942 942 (% class="box infomessage" %) 943 943 ((( ... ... @@ -945,7 +945,7 @@ 945 945 ))) 946 946 947 947 948 -* Downlink Payload (prefix 0xAA 01 ): 936 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 01 ): 949 949 950 950 (% class="box infomessage" %) 951 951 ((( ... ... @@ -958,7 +958,7 @@ 958 958 959 959 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 960 960 961 -* AT Command: 949 +* (% style="color:#037691" %)AT Command: 962 962 963 963 (% class="box infomessage" %) 964 964 ((( ... ... @@ -966,7 +966,7 @@ 966 966 ))) 967 967 968 968 969 -* Downlink Payload (prefix 0xAA 00 ): 957 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 00 ): 970 970 971 971 (% class="box infomessage" %) 972 972 ((( ... ... @@ -979,7 +979,7 @@ 979 979 980 980 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 981 981 982 -* AT Command: 970 +* (% style="color:#037691" %)AT Command: 983 983 984 984 (% class="box infomessage" %) 985 985 ((( ... ... @@ -987,7 +987,7 @@ 987 987 ))) 988 988 989 989 990 -* Downlink Payload (prefix 0xAC ): 978 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAC ): 991 991 992 992 (% class="box infomessage" %) 993 993 ((( ... ... @@ -998,12 +998,12 @@ 998 998 999 999 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 1000 1000 1001 -* AT Command: 989 +* (% style="color:#037691" %)AT Command: 1002 1002 1003 1003 There is no AT Command to control Digital Output 1004 1004 1005 1005 1006 -* Downlink Payload (prefix 0x02): 994 +* (% style="color:#037691" %)Downlink Payload (prefix 0x02): 1007 1007 1008 1008 (% class="box infomessage" %) 1009 1009 ((( ... ... @@ -1032,12 +1032,12 @@ 1032 1032 1033 1033 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1034 1034 1035 -* AT Command: 1023 +* (% style="color:#037691" %)AT Command: 1036 1036 1037 1037 There is no AT Command to control Digital Output 1038 1038 1039 1039 1040 -* Downlink Payload (prefix 0xA9): 1028 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA9): 1041 1041 1042 1042 (% class="box infomessage" %) 1043 1043 ((( ... ... @@ -1099,14 +1099,14 @@ 1099 1099 1100 1100 1101 1101 1102 -=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 === 1090 +==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1103 1103 1104 -* AT Command: 1092 +* (% style="color:#037691" %)AT Command: 1105 1105 1106 1106 There is no AT Command to control Relay Output 1107 1107 1108 1108 1109 -* Downlink Payload (prefix 0x03): 1097 +* (% style="color:#037691" %)Downlink Payload (prefix 0x03): 1110 1110 1111 1111 (% class="box infomessage" %) 1112 1112 ((( ... ... @@ -1131,12 +1131,12 @@ 1131 1131 1132 1132 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1133 1133 1134 -* AT Command: 1122 +* (% style="color:#037691" %)AT Command: 1135 1135 1136 1136 There is no AT Command to control Relay Output 1137 1137 1138 1138 1139 -* Downlink Payload (prefix 0x05): 1127 +* (% style="color:#037691" %)Downlink Payload (prefix 0x05): 1140 1140 1141 1141 (% class="box infomessage" %) 1142 1142 ((( ... ... @@ -1188,7 +1188,7 @@ 1188 1188 1189 1189 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1190 1190 1191 -* AT Command: 1179 +* (% style="color:#037691" %)AT Command: 1192 1192 1193 1193 (% class="box infomessage" %) 1194 1194 ((( ... ... @@ -1196,7 +1196,7 @@ 1196 1196 ))) 1197 1197 1198 1198 1199 -* Downlink Payload (prefix 0xA5): 1187 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA5): 1200 1200 1201 1201 (% class="box infomessage" %) 1202 1202 ((( ... ... @@ -1207,7 +1207,7 @@ 1207 1207 1208 1208 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1209 1209 1210 -* AT Command: 1198 +* (% style="color:#037691" %)AT Command: 1211 1211 1212 1212 (% class="box infomessage" %) 1213 1213 ((( ... ... @@ -1223,7 +1223,7 @@ 1223 1223 Bb cc dd ee: number to be set 1224 1224 1225 1225 1226 -* Downlink Payload (prefix 0xA8): 1214 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA8): 1227 1227 1228 1228 (% class="box infomessage" %) 1229 1229 ((( ... ... @@ -1236,7 +1236,7 @@ 1236 1236 1237 1237 Clear counting for counting mode 1238 1238 1239 -* AT Command: 1227 +* (% style="color:#037691" %)AT Command: 1240 1240 1241 1241 (% class="box infomessage" %) 1242 1242 ((( ... ... @@ -1243,7 +1243,7 @@ 1243 1243 **AT+CLRCOUNT ~/~/ clear all counting** 1244 1244 ))) 1245 1245 1246 -* Downlink Payload (prefix 0xA6): 1234 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA6): 1247 1247 1248 1248 (% class="box infomessage" %) 1249 1249 ((( ... ... @@ -1254,7 +1254,7 @@ 1254 1254 1255 1255 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1256 1256 1257 -* AT Command: 1245 +* (% style="color:#037691" %)AT Command: 1258 1258 1259 1259 (% class="box infomessage" %) 1260 1260 ((( ... ... @@ -1261,7 +1261,7 @@ 1261 1261 **AT+COUTIME=60 ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)** 1262 1262 ))) 1263 1263 1264 -* Downlink Payload (prefix 0xA7): 1252 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA7): 1265 1265 1266 1266 (% class="box infomessage" %) 1267 1267 ((( ... ... @@ -1964,8 +1964,16 @@ 1964 1964 ))) 1965 1965 1966 1966 ((( 1967 - 1955 +== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? == 1968 1968 1957 +If the device is not shut down, but directly powered off. 1958 + 1959 +It will default that this is a power-off state. 1960 + 1961 +In modes 2 to 5, DO RO status and pulse count are saved in flash. 1962 + 1963 +After restart, the status before power failure will be read from flash. 1964 + 1969 1969 = 6. Trouble Shooting = 1970 1970 ))) 1971 1971