Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -666,6 +666,7 @@ 666 666 667 667 Same as AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 668 668 669 + 669 669 (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:** 670 670 671 671 MOD6 Payload : total 11 bytes payload ... ... @@ -672,6 +672,7 @@ 672 672 673 673 [[image:image-20220524085923-1.png]] 674 674 676 + 675 675 (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below 676 676 677 677 [[image:image-20220524090106-2.png]] ... ... @@ -678,6 +678,7 @@ 678 678 679 679 * Each bits shows if the corresponding trigger has been configured. 680 680 683 + 681 681 **Example:** 682 682 683 683 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -689,6 +689,7 @@ 689 689 690 690 * Each bits shows which status has been trigger on this uplink. 691 691 695 + 692 692 **Example:** 693 693 694 694 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. ... ... @@ -739,6 +739,8 @@ 739 739 740 740 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 741 741 746 + 747 + 742 742 === 3.4.1 Common Commands === 743 743 744 744 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -760,6 +760,7 @@ 760 760 761 761 **Example: **AT+TDC=30000. Means set interval to 30 seconds 762 762 769 + 763 763 * Downlink Payload (prefix 0x01): 764 764 765 765 (% class="box infomessage" %) ... ... @@ -782,6 +782,7 @@ 782 782 783 783 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 784 784 792 + 785 785 * Downlink Payload (prefix 0x0A): 786 786 787 787 (% class="box infomessage" %) ... ... @@ -797,6 +797,7 @@ 797 797 798 798 There is no AT Command to poll uplink 799 799 808 + 800 800 * Downlink Payload (prefix 0x08): 801 801 802 802 (% class="box infomessage" %) ... ... @@ -823,6 +823,7 @@ 823 823 824 824 0: Disable Trigger Mode 825 825 835 + 826 826 * Downlink Payload (prefix 0x0A 06): 827 827 828 828 (% class="box infomessage" %) ... ... @@ -840,6 +840,7 @@ 840 840 841 841 There is no AT Command for this feature. 842 842 853 + 843 843 * Downlink Payload (prefix 0x AB 06): 844 844 845 845 (% class="box infomessage" %) ... ... @@ -860,6 +860,7 @@ 860 860 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 861 861 ))) 862 862 874 + 863 863 **Example:** 864 864 865 865 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) ... ... @@ -1099,7 +1099,7 @@ 1099 1099 1100 1100 1101 1101 1102 -=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 === 1114 +==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1103 1103 1104 1104 * AT Command: 1105 1105