... ... @@ -666,6 +666,7 @@
666 666  
667 667  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
668 668  
669 +
669 669  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
670 670  
671 671  MOD6 Payload : total 11 bytes payload
... ... @@ -672,6 +672,7 @@
672 672  
673 673  [[image:image-20220524085923-1.png]]
674 674  
676 +
675 675  (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below
676 676  
677 677  [[image:image-20220524090106-2.png]]
... ... @@ -678,6 +678,7 @@
678 678  
679 679  * Each bits shows if the corresponding trigger has been configured.
680 680  
683 +
681 681  **Example:**
682 682  
683 683  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -689,6 +689,7 @@
689 689  
690 690  * Each bits shows which status has been trigger on this uplink.
691 691  
695 +
692 692  **Example:**
693 693  
694 694  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -739,6 +739,8 @@
739 739  
740 740  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
741 741  
746 +
747 +
742 742  === 3.4.1 Common Commands ===
743 743  
744 744  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -760,6 +760,7 @@
760 760  
761 761  **Example: **AT+TDC=30000. Means set interval to 30 seconds
762 762  
769 +
763 763  * Downlink Payload (prefix 0x01):
764 764  
765 765  (% class="box infomessage" %)
... ... @@ -782,6 +782,7 @@
782 782  
783 783  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
784 784  
792 +
785 785  * Downlink Payload (prefix 0x0A):
786 786  
787 787  (% class="box infomessage" %)
... ... @@ -797,6 +797,7 @@
797 797  
798 798  There is no AT Command to poll uplink
799 799  
808 +
800 800  * Downlink Payload (prefix 0x08):
801 801  
802 802  (% class="box infomessage" %)
... ... @@ -823,6 +823,7 @@
823 823  
824 824  0: Disable Trigger Mode
825 825  
835 +
826 826  * Downlink Payload (prefix 0x0A 06):
827 827  
828 828  (% class="box infomessage" %)
... ... @@ -840,6 +840,7 @@
840 840  
841 841  There is no AT Command for this feature.
842 842  
853 +
843 843  * Downlink Payload (prefix 0x AB 06):
844 844  
845 845  (% class="box infomessage" %)
... ... @@ -860,6 +860,7 @@
860 860  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
861 861  )))
862 862  
874 +
863 863  **Example:**
864 864  
865 865  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -1099,7 +1099,7 @@
1099 1099  
1100 1100  
1101 1101  
1102 -=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
1114 +==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1103 1103  
1104 1104  * AT Command:
1105 1105  