... ... @@ -888,12 +888,10 @@
888 888  
889 889  b : delay timing.
890 890  
891 -
892 892  **Example:**
893 893  
894 894  AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms )
895 895  
896 -
897 897  * Downlink Payload (prefix 0x09 01 ):
898 898  
899 899  (% class="box infomessage" %)
... ... @@ -918,12 +918,10 @@
918 918  
919 919  b : delay timing.
920 920  
921 -
922 922  **Example:**
923 923  
924 924  AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms )
925 925  
926 -
927 927  * Downlink Payload (prefix 0x09 02 ):
928 928  
929 929  (% class="box infomessage" %)
... ... @@ -944,7 +944,6 @@
944 944  **AT+ACLIM. **
945 945  )))
946 946  
947 -
948 948  * Downlink Payload (prefix 0xAA 01 ):
949 949  
950 950  (% class="box infomessage" %)
... ... @@ -965,7 +965,6 @@
965 965  **AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
966 966  )))
967 967  
968 -
969 969  * Downlink Payload (prefix 0xAA 00 ):
970 970  
971 971  (% class="box infomessage" %)
... ... @@ -986,7 +986,6 @@
986 986  **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.**
987 987  )))
988 988  
989 -
990 990  * Downlink Payload (prefix 0xAC ):
991 991  
992 992  (% class="box infomessage" %)
... ... @@ -1002,7 +1002,6 @@
1002 1002  
1003 1003  There is no AT Command to control Digital Output
1004 1004  
1005 -
1006 1006  * Downlink Payload (prefix 0x02):
1007 1007  
1008 1008  (% class="box infomessage" %)
... ... @@ -1036,7 +1036,6 @@
1036 1036  
1037 1037  There is no AT Command to control Digital Output
1038 1038  
1039 -
1040 1040  * Downlink Payload (prefix 0xA9):
1041 1041  
1042 1042  (% class="box infomessage" %)
... ... @@ -1056,22 +1056,18 @@
1056 1056  
1057 1057  00: DO pins will change to an inverter state after timeout 
1058 1058  
1059 -
1060 1060  (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status:
1061 1061  
1062 1062  [[image:image-20220524093238-6.png]]
1063 1063  
1064 -
1065 1065  (% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status:
1066 1066  
1067 1067  [[image:image-20220524093328-7.png]]
1068 1068  
1069 -
1070 1070  (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status:
1071 1071  
1072 1072  [[image:image-20220524093351-8.png]]
1073 1073  
1074 -
1075 1075  (% style="color:#4f81bd" %)**Sixth and Seventh Byte**:
1076 1076  
1077 1077   Latching time. Unit: ms
... ... @@ -1078,7 +1078,6 @@
1078 1078  
1079 1079  Device will upload a packet if downlink code executes successfully.
1080 1080  
1081 -
1082 1082  **Example payload:**
1083 1083  
1084 1084  **~1. A9 01 01 01 01 07 D0**
... ... @@ -1105,7 +1105,6 @@
1105 1105  
1106 1106  There is no AT Command to control Relay Output
1107 1107  
1108 -
1109 1109  * Downlink Payload (prefix 0x03):
1110 1110  
1111 1111  (% class="box infomessage" %)
... ... @@ -1135,7 +1135,6 @@
1135 1135  
1136 1136  There is no AT Command to control Relay Output
1137 1137  
1138 -
1139 1139  * Downlink Payload (prefix 0x05):
1140 1140  
1141 1141  (% class="box infomessage" %)
... ... @@ -1153,17 +1153,14 @@
1153 1153  
1154 1154  00: Relays will change to an inverter state after timeout
1155 1155  
1156 -
1157 1157  (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status:
1158 1158  
1159 1159  [[image:image-20220524093831-10.png]]
1160 1160  
1161 -
1162 1162  (% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms
1163 1163  
1164 1164  Device will upload a packet if downlink code executes successfully.
1165 1165  
1166 -
1167 1167  **Example payload:**
1168 1168  
1169 1169  **~1. 05 01 11 07 D0**
... ... @@ -1195,7 +1195,6 @@
1195 1195  **AT+VOLMAX    ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]**
1196 1196  )))
1197 1197  
1198 -
1199 1199  * Downlink Payload (prefix 0xA5):
1200 1200  
1201 1201  (% class="box infomessage" %)
... ... @@ -1222,7 +1222,6 @@
1222 1222  
1223 1223  Bb cc dd ee: number to be set
1224 1224  
1225 -
1226 1226  * Downlink Payload (prefix 0xA8):
1227 1227  
1228 1228  (% class="box infomessage" %)
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved