Summary

Details

Page properties
Content
... ... @@ -888,12 +888,10 @@
888 888  
889 889  b : delay timing.
890 890  
891 -
892 892  **Example:**
893 893  
894 894  AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms )
895 895  
896 -
897 897  * Downlink Payload (prefix 0x09 01 ):
898 898  
899 899  (% class="box infomessage" %)
... ... @@ -918,12 +918,10 @@
918 918  
919 919  b : delay timing.
920 920  
921 -
922 922  **Example:**
923 923  
924 924  AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms )
925 925  
926 -
927 927  * Downlink Payload (prefix 0x09 02 ):
928 928  
929 929  (% class="box infomessage" %)
... ... @@ -944,7 +944,6 @@
944 944  **AT+ACLIM. **
945 945  )))
946 946  
947 -
948 948  * Downlink Payload (prefix 0xAA 01 ):
949 949  
950 950  (% class="box infomessage" %)
... ... @@ -965,7 +965,6 @@
965 965  **AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
966 966  )))
967 967  
968 -
969 969  * Downlink Payload (prefix 0xAA 00 ):
970 970  
971 971  (% class="box infomessage" %)
... ... @@ -986,7 +986,6 @@
986 986  **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.**
987 987  )))
988 988  
989 -
990 990  * Downlink Payload (prefix 0xAC ):
991 991  
992 992  (% class="box infomessage" %)
... ... @@ -1002,7 +1002,6 @@
1002 1002  
1003 1003  There is no AT Command to control Digital Output
1004 1004  
1005 -
1006 1006  * Downlink Payload (prefix 0x02):
1007 1007  
1008 1008  (% class="box infomessage" %)
... ... @@ -1036,7 +1036,6 @@
1036 1036  
1037 1037  There is no AT Command to control Digital Output
1038 1038  
1039 -
1040 1040  * Downlink Payload (prefix 0xA9):
1041 1041  
1042 1042  (% class="box infomessage" %)
... ... @@ -1056,22 +1056,18 @@
1056 1056  
1057 1057  00: DO pins will change to an inverter state after timeout 
1058 1058  
1059 -
1060 1060  (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status:
1061 1061  
1062 1062  [[image:image-20220524093238-6.png]]
1063 1063  
1064 -
1065 1065  (% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status:
1066 1066  
1067 1067  [[image:image-20220524093328-7.png]]
1068 1068  
1069 -
1070 1070  (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status:
1071 1071  
1072 1072  [[image:image-20220524093351-8.png]]
1073 1073  
1074 -
1075 1075  (% style="color:#4f81bd" %)**Sixth and Seventh Byte**:
1076 1076  
1077 1077   Latching time. Unit: ms
... ... @@ -1078,7 +1078,6 @@
1078 1078  
1079 1079  Device will upload a packet if downlink code executes successfully.
1080 1080  
1081 -
1082 1082  **Example payload:**
1083 1083  
1084 1084  **~1. A9 01 01 01 01 07 D0**
... ... @@ -1105,7 +1105,6 @@
1105 1105  
1106 1106  There is no AT Command to control Relay Output
1107 1107  
1108 -
1109 1109  * Downlink Payload (prefix 0x03):
1110 1110  
1111 1111  (% class="box infomessage" %)
... ... @@ -1135,7 +1135,6 @@
1135 1135  
1136 1136  There is no AT Command to control Relay Output
1137 1137  
1138 -
1139 1139  * Downlink Payload (prefix 0x05):
1140 1140  
1141 1141  (% class="box infomessage" %)
... ... @@ -1153,17 +1153,14 @@
1153 1153  
1154 1154  00: Relays will change to an inverter state after timeout
1155 1155  
1156 -
1157 1157  (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status:
1158 1158  
1159 1159  [[image:image-20220524093831-10.png]]
1160 1160  
1161 -
1162 1162  (% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms
1163 1163  
1164 1164  Device will upload a packet if downlink code executes successfully.
1165 1165  
1166 -
1167 1167  **Example payload:**
1168 1168  
1169 1169  **~1. 05 01 11 07 D0**
... ... @@ -1195,7 +1195,6 @@
1195 1195  **AT+VOLMAX    ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]**
1196 1196  )))
1197 1197  
1198 -
1199 1199  * Downlink Payload (prefix 0xA5):
1200 1200  
1201 1201  (% class="box infomessage" %)
... ... @@ -1222,7 +1222,6 @@
1222 1222  
1223 1223  Bb cc dd ee: number to be set
1224 1224  
1225 -
1226 1226  * Downlink Payload (prefix 0xA8):
1227 1227  
1228 1228  (% class="box infomessage" %)
... ... @@ -1275,6 +1275,7 @@
1275 1275  )))
1276 1276  
1277 1277  
1257 +
1278 1278  == 3.5 Integrate with Mydevice ==
1279 1279  
1280 1280  Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: