Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -888,10 +888,12 @@ 888 888 889 889 b : delay timing. 890 890 891 + 891 891 **Example:** 892 892 893 893 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 894 894 896 + 895 895 * Downlink Payload (prefix 0x09 01 ): 896 896 897 897 (% class="box infomessage" %) ... ... @@ -916,10 +916,12 @@ 916 916 917 917 b : delay timing. 918 918 921 + 919 919 **Example:** 920 920 921 921 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 922 922 926 + 923 923 * Downlink Payload (prefix 0x09 02 ): 924 924 925 925 (% class="box infomessage" %) ... ... @@ -940,6 +940,7 @@ 940 940 **AT+ACLIM. ** 941 941 ))) 942 942 947 + 943 943 * Downlink Payload (prefix 0xAA 01 ): 944 944 945 945 (% class="box infomessage" %) ... ... @@ -960,6 +960,7 @@ 960 960 **AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 961 961 ))) 962 962 968 + 963 963 * Downlink Payload (prefix 0xAA 00 ): 964 964 965 965 (% class="box infomessage" %) ... ... @@ -980,6 +980,7 @@ 980 980 **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.** 981 981 ))) 982 982 989 + 983 983 * Downlink Payload (prefix 0xAC ): 984 984 985 985 (% class="box infomessage" %) ... ... @@ -995,6 +995,7 @@ 995 995 996 996 There is no AT Command to control Digital Output 997 997 1005 + 998 998 * Downlink Payload (prefix 0x02): 999 999 1000 1000 (% class="box infomessage" %) ... ... @@ -1028,6 +1028,7 @@ 1028 1028 1029 1029 There is no AT Command to control Digital Output 1030 1030 1039 + 1031 1031 * Downlink Payload (prefix 0xA9): 1032 1032 1033 1033 (% class="box infomessage" %) ... ... @@ -1047,18 +1047,22 @@ 1047 1047 1048 1048 00: DO pins will change to an inverter state after timeout 1049 1049 1059 + 1050 1050 (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status: 1051 1051 1052 1052 [[image:image-20220524093238-6.png]] 1053 1053 1064 + 1054 1054 (% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status: 1055 1055 1056 1056 [[image:image-20220524093328-7.png]] 1057 1057 1069 + 1058 1058 (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status: 1059 1059 1060 1060 [[image:image-20220524093351-8.png]] 1061 1061 1074 + 1062 1062 (% style="color:#4f81bd" %)**Sixth and Seventh Byte**: 1063 1063 1064 1064 Latching time. Unit: ms ... ... @@ -1065,6 +1065,7 @@ 1065 1065 1066 1066 Device will upload a packet if downlink code executes successfully. 1067 1067 1081 + 1068 1068 **Example payload:** 1069 1069 1070 1070 **~1. A9 01 01 01 01 07 D0** ... ... @@ -1091,6 +1091,7 @@ 1091 1091 1092 1092 There is no AT Command to control Relay Output 1093 1093 1108 + 1094 1094 * Downlink Payload (prefix 0x03): 1095 1095 1096 1096 (% class="box infomessage" %)