Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -666,6 +666,7 @@ 666 666 667 667 Same as AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 668 668 669 + 669 669 (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:** 670 670 671 671 MOD6 Payload : total 11 bytes payload ... ... @@ -672,6 +672,7 @@ 672 672 673 673 [[image:image-20220524085923-1.png]] 674 674 676 + 675 675 (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below 676 676 677 677 [[image:image-20220524090106-2.png]] ... ... @@ -678,6 +678,7 @@ 678 678 679 679 * Each bits shows if the corresponding trigger has been configured. 680 680 683 + 681 681 **Example:** 682 682 683 683 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -739,6 +739,8 @@ 739 739 740 740 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 741 741 745 + 746 + 742 742 === 3.4.1 Common Commands === 743 743 744 744 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -760,6 +760,7 @@ 760 760 761 761 **Example: **AT+TDC=30000. Means set interval to 30 seconds 762 762 768 + 763 763 * Downlink Payload (prefix 0x01): 764 764 765 765 (% class="box infomessage" %) ... ... @@ -782,6 +782,7 @@ 782 782 783 783 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 784 784 791 + 785 785 * Downlink Payload (prefix 0x0A): 786 786 787 787 (% class="box infomessage" %) ... ... @@ -797,6 +797,7 @@ 797 797 798 798 There is no AT Command to poll uplink 799 799 807 + 800 800 * Downlink Payload (prefix 0x08): 801 801 802 802 (% class="box infomessage" %) ... ... @@ -823,6 +823,7 @@ 823 823 824 824 0: Disable Trigger Mode 825 825 834 + 826 826 * Downlink Payload (prefix 0x0A 06): 827 827 828 828 (% class="box infomessage" %) ... ... @@ -840,6 +840,7 @@ 840 840 841 841 There is no AT Command for this feature. 842 842 852 + 843 843 * Downlink Payload (prefix 0x AB 06): 844 844 845 845 (% class="box infomessage" %) ... ... @@ -860,6 +860,7 @@ 860 860 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 861 861 ))) 862 862 873 + 863 863 **Example:** 864 864 865 865 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) ... ... @@ -888,10 +888,12 @@ 888 888 889 889 b : delay timing. 890 890 902 + 891 891 **Example:** 892 892 893 893 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 894 894 907 + 895 895 * Downlink Payload (prefix 0x09 01 ): 896 896 897 897 (% class="box infomessage" %) ... ... @@ -916,10 +916,12 @@ 916 916 917 917 b : delay timing. 918 918 932 + 919 919 **Example:** 920 920 921 921 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 922 922 937 + 923 923 * Downlink Payload (prefix 0x09 02 ): 924 924 925 925 (% class="box infomessage" %) ... ... @@ -940,6 +940,7 @@ 940 940 **AT+ACLIM. ** 941 941 ))) 942 942 958 + 943 943 * Downlink Payload (prefix 0xAA 01 ): 944 944 945 945 (% class="box infomessage" %) ... ... @@ -960,6 +960,7 @@ 960 960 **AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 961 961 ))) 962 962 979 + 963 963 * Downlink Payload (prefix 0xAA 00 ): 964 964 965 965 (% class="box infomessage" %) ... ... @@ -980,6 +980,7 @@ 980 980 **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.** 981 981 ))) 982 982 1000 + 983 983 * Downlink Payload (prefix 0xAC ): 984 984 985 985 (% class="box infomessage" %) ... ... @@ -995,6 +995,7 @@ 995 995 996 996 There is no AT Command to control Digital Output 997 997 1016 + 998 998 * Downlink Payload (prefix 0x02): 999 999 1000 1000 (% class="box infomessage" %) ... ... @@ -1028,6 +1028,7 @@ 1028 1028 1029 1029 There is no AT Command to control Digital Output 1030 1030 1050 + 1031 1031 * Downlink Payload (prefix 0xA9): 1032 1032 1033 1033 (% class="box infomessage" %) ... ... @@ -1047,18 +1047,22 @@ 1047 1047 1048 1048 00: DO pins will change to an inverter state after timeout 1049 1049 1070 + 1050 1050 (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status: 1051 1051 1052 1052 [[image:image-20220524093238-6.png]] 1053 1053 1075 + 1054 1054 (% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status: 1055 1055 1056 1056 [[image:image-20220524093328-7.png]] 1057 1057 1080 + 1058 1058 (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status: 1059 1059 1060 1060 [[image:image-20220524093351-8.png]] 1061 1061 1085 + 1062 1062 (% style="color:#4f81bd" %)**Sixth and Seventh Byte**: 1063 1063 1064 1064 Latching time. Unit: ms ... ... @@ -1065,6 +1065,7 @@ 1065 1065 1066 1066 Device will upload a packet if downlink code executes successfully. 1067 1067 1092 + 1068 1068 **Example payload:** 1069 1069 1070 1070 **~1. A9 01 01 01 01 07 D0** ... ... @@ -1085,12 +1085,13 @@ 1085 1085 1086 1086 1087 1087 1088 -=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 === 1113 +==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1089 1089 1090 1090 * AT Command: 1091 1091 1092 1092 There is no AT Command to control Relay Output 1093 1093 1119 + 1094 1094 * Downlink Payload (prefix 0x03): 1095 1095 1096 1096 (% class="box infomessage" %) ... ... @@ -1120,6 +1120,7 @@ 1120 1120 1121 1121 There is no AT Command to control Relay Output 1122 1122 1149 + 1123 1123 * Downlink Payload (prefix 0x05): 1124 1124 1125 1125 (% class="box infomessage" %) ... ... @@ -1179,6 +1179,7 @@ 1179 1179 **AT+VOLMAX ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]** 1180 1180 ))) 1181 1181 1209 + 1182 1182 * Downlink Payload (prefix 0xA5): 1183 1183 1184 1184 (% class="box infomessage" %) ... ... @@ -1205,6 +1205,7 @@ 1205 1205 1206 1206 Bb cc dd ee: number to be set 1207 1207 1236 + 1208 1208 * Downlink Payload (prefix 0xA8): 1209 1209 1210 1210 (% class="box infomessage" %)