659 659   Yy4 yy4: AC2 or AV2 high limit.
660 660  
661 +
661 661  **Example1**: AA 00 13 88 00 00 00 00 00 00
662 662  
663 663  Same as AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
664 664  
666 +
665 665  **Example2**: AA 02 01 00
666 666  
667 667  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
668 668  
671 +
669 669  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
670 670  
671 671  MOD6 Payload : total 11 bytes payload
... ... @@ -672,6 +672,7 @@
672 672  
673 673  [[image:image-20220524085923-1.png]]
674 674  
678 +
675 675  (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below
676 676  
677 677  [[image:image-20220524090106-2.png]]
... ... @@ -678,6 +678,7 @@
678 678  
679 679  * Each bits shows if the corresponding trigger has been configured.
680 680  
685 +
681 681  **Example:**
682 682  
683 683  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -689,6 +689,7 @@
689 689  
690 690  * Each bits shows which status has been trigger on this uplink.
691 691  
697 +
692 692  **Example:**
693 693  
694 694  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -700,6 +700,7 @@
700 700  
701 701  * Each bits shows which status has been trigger on this uplink.
702 702  
709 +
703 703  **Example:**
704 704  
705 705  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -739,6 +739,8 @@
739 739  
740 740  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
741 741  
749 +
750 +
742 742  === 3.4.1 Common Commands ===
743 743  
744 744  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -760,6 +760,7 @@
760 760  
761 761  **Example: **AT+TDC=30000. Means set interval to 30 seconds
762 762  
772 +
763 763  * Downlink Payload (prefix 0x01):
764 764  
765 765  (% class="box infomessage" %)
... ... @@ -782,6 +782,7 @@
782 782  
783 783  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
784 784  
795 +
785 785  * Downlink Payload (prefix 0x0A):
786 786  
787 787  (% class="box infomessage" %)
... ... @@ -797,6 +797,7 @@
797 797  
798 798  There is no AT Command to poll uplink
799 799  
811 +
800 800  * Downlink Payload (prefix 0x08):
801 801  
802 802  (% class="box infomessage" %)
... ... @@ -823,6 +823,7 @@
823 823  
824 824  0: Disable Trigger Mode
825 825  
838 +
826 826  * Downlink Payload (prefix 0x0A 06):
827 827  
828 828  (% class="box infomessage" %)
... ... @@ -840,6 +840,7 @@
840 840  
841 841  There is no AT Command for this feature.
842 842  
856 +
843 843  * Downlink Payload (prefix 0x AB 06):
844 844  
845 845  (% class="box infomessage" %)
... ... @@ -860,6 +860,7 @@
860 860  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
861 861  )))
862 862  
877 +
863 863  **Example:**
864 864  
865 865  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -888,10 +888,12 @@
888 888  
889 889  b : delay timing.
890 890  
906 +
891 891  **Example:**
892 892  
893 893  AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms )
894 894  
911 +
895 895  * Downlink Payload (prefix 0x09 01 ):
896 896  
897 897  (% class="box infomessage" %)
... ... @@ -916,10 +916,12 @@
916 916  
917 917  b : delay timing.
918 918  
936 +
919 919  **Example:**
920 920  
921 921  AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms )
922 922  
941 +
923 923  * Downlink Payload (prefix 0x09 02 ):
924 924  
925 925  (% class="box infomessage" %)
... ... @@ -940,6 +940,7 @@
940 940  **AT+ACLIM. **
941 941  )))
942 942  
962 +
943 943  * Downlink Payload (prefix 0xAA 01 ):
944 944  
945 945  (% class="box infomessage" %)
... ... @@ -960,6 +960,7 @@
960 960  **AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
961 961  )))
962 962  
983 +
963 963  * Downlink Payload (prefix 0xAA 00 ):
964 964  
965 965  (% class="box infomessage" %)
... ... @@ -980,6 +980,7 @@
980 980  **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.**
981 981  )))
982 982  
1004 +
983 983  * Downlink Payload (prefix 0xAC ):
984 984  
985 985  (% class="box infomessage" %)
... ... @@ -995,6 +995,7 @@
995 995  
996 996  There is no AT Command to control Digital Output
997 997  
1020 +
998 998  * Downlink Payload (prefix 0x02):
999 999  
1000 1000  (% class="box infomessage" %)
... ... @@ -1028,6 +1028,7 @@
1028 1028  
1029 1029  There is no AT Command to control Digital Output
1030 1030  
1054 +
1031 1031  * Downlink Payload (prefix 0xA9):
1032 1032  
1033 1033  (% class="box infomessage" %)
... ... @@ -1047,18 +1047,22 @@
1047 1047  
1048 1048  00: DO pins will change to an inverter state after timeout 
1049 1049  
1074 +
1050 1050  (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status:
1051 1051  
1052 1052  [[image:image-20220524093238-6.png]]
1053 1053  
1079 +
1054 1054  (% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status:
1055 1055  
1056 1056  [[image:image-20220524093328-7.png]]
1057 1057  
1084 +
1058 1058  (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status:
1059 1059  
1060 1060  [[image:image-20220524093351-8.png]]
1061 1061  
1089 +
1062 1062  (% style="color:#4f81bd" %)**Sixth and Seventh Byte**:
1063 1063  
1064 1064   Latching time. Unit: ms
... ... @@ -1065,6 +1065,7 @@
1065 1065  
1066 1066  Device will upload a packet if downlink code executes successfully.
1067 1067  
1096 +
1068 1068  **Example payload:**
1069 1069  
1070 1070  **~1. A9 01 01 01 01 07 D0**
... ... @@ -1085,12 +1085,13 @@
1085 1085  
1086 1086  
1087 1087  
1088 -=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
1117 +==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1089 1089  
1090 1090  * AT Command:
1091 1091  
1092 1092  There is no AT Command to control Relay Output
1093 1093  
1123 +
1094 1094  * Downlink Payload (prefix 0x03):
1095 1095  
1096 1096  (% class="box infomessage" %)
... ... @@ -1120,6 +1120,7 @@
1120 1120  
1121 1121  There is no AT Command to control Relay Output
1122 1122  
1153 +
1123 1123  * Downlink Payload (prefix 0x05):
1124 1124  
1125 1125  (% class="box infomessage" %)
... ... @@ -1137,10 +1137,12 @@
1137 1137  
1138 1138  00: Relays will change to an inverter state after timeout
1139 1139  
1171 +
1140 1140  (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status:
1141 1141  
1142 1142  [[image:image-20220524093831-10.png]]
1143 1143  
1176 +
1144 1144  (% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms
1145 1145  
1146 1146  Device will upload a packet if downlink code executes successfully.
... ... @@ -1177,6 +1177,7 @@
1177 1177  **AT+VOLMAX    ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]**
1178 1178  )))
1179 1179  
1213 +
1180 1180  * Downlink Payload (prefix 0xA5):
1181 1181  
1182 1182  (% class="box infomessage" %)
... ... @@ -1203,6 +1203,7 @@
1203 1203  
1204 1204  Bb cc dd ee: number to be set
1205 1205  
1240 +
1206 1206  * Downlink Payload (prefix 0xA8):
1207 1207  
1208 1208  (% class="box infomessage" %)
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0