<
From version < 77.60 >
edited by Xiaoling
on 2022/06/10 09:13
To version < 77.50 >
edited by Xiaoling
on 2022/06/10 09:05
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1260,11 +1260,11 @@
1260 1260  Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps:
1261 1261  
1262 1262  (((
1263 -(% style="color:blue" %)**Step 1**(%%): Be sure that your device is programmed and properly connected to the network at this time.
1263 +**Step 1**: Be sure that your device is programmed and properly connected to the network at this time.
1264 1264  )))
1265 1265  
1266 1266  (((
1267 -(% style="color:blue" %)**Step 2**(%%): To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps:
1267 +**Step 2**: To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps:
1268 1268  )))
1269 1269  
1270 1270  [[image:1653356737703-362.png||height="232" width="732"]]
... ... @@ -1271,13 +1271,12 @@
1271 1271  
1272 1272  [[image:image-20220524094641-11.png||height="390" width="723"]]
1273 1273  
1274 -
1275 1275  [[image:image-20220524094641-12.png||height="402" width="718"]]
1276 1276  
1277 1277  
1278 -(% style="color:blue" %)**Step 3**(%%): Create an account or log in Mydevices.
1277 +**Step 3**: Create an account or log in Mydevices.
1279 1279  
1280 -(% style="color:blue" %)**Step 4**(%%): Search LT-22222-L(for both LT-22222-L / LT-33222-L) and add DevEUI.(% style="display:none" %)
1279 +**Step 4**: Search LT-22222-L(for both LT-22222-L / LT-33222-L) and add DevEUI.(% style="display:none" %)
1281 1281  
1282 1282  Search under The things network
1283 1283  
... ... @@ -1284,21 +1284,16 @@
1284 1284  [[image:1653356838789-523.png||height="337" width="740"]]
1285 1285  
1286 1286  
1287 -
1288 1288  After added, the sensor data arrive TTN, it will also arrive and show in Mydevices.
1289 1289  
1290 1290  [[image:image-20220524094909-1.png||height="335" width="729"]]
1291 1291  
1292 -
1293 1293  [[image:image-20220524094909-2.png||height="337" width="729"]]
1294 1294  
1295 -
1296 1296  [[image:image-20220524094909-3.png||height="338" width="727"]]
1297 1297  
1298 -
1299 1299  [[image:image-20220524094909-4.png||height="339" width="728"]](% style="display:none" %)
1300 1300  
1301 -
1302 1302  [[image:image-20220524094909-5.png||height="341" width="734"]]
1303 1303  
1304 1304  
... ... @@ -1338,7 +1338,7 @@
1338 1338  )))
1339 1339  
1340 1340  (((
1341 -(% style="color:blue" %)**Example1**(%%): Connect to a Low active sensor.
1335 +**Example1**: Connect to a Low active sensor.
1342 1342  )))
1343 1343  
1344 1344  (((
... ... @@ -1369,7 +1369,7 @@
1369 1369  )))
1370 1370  
1371 1371  (((
1372 -(% style="color:blue" %)**Example2**(%%): Connect to a High active sensor.
1366 +**Example2**: Connect to a High active sensor.
1373 1373  )))
1374 1374  
1375 1375  (((
... ... @@ -1400,7 +1400,7 @@
1400 1400  )))
1401 1401  
1402 1402  (((
1403 -(% style="color:blue" %)**Example3**(%%): Connect to a 220v high active sensor.
1397 +**Example3**: Connect to a 220v high active sensor.
1404 1404  )))
1405 1405  
1406 1406  (((
... ... @@ -1440,9 +1440,8 @@
1440 1440  
1441 1441  The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is:
1442 1442  
1437 +**AC2 = (IN2 voltage )/12**
1443 1443  
1444 -(% style="color:blue" %)**AC2 = (IN2 voltage )/12**
1445 -
1446 1446  [[image:1653357592296-182.png]]
1447 1447  
1448 1448  Example to connect a 4~~20mA sensor
... ... @@ -1449,18 +1449,17 @@
1449 1449  
1450 1450  We take the wind speed sensor as an example for reference only.
1451 1451  
1445 +Specifications of the wind speed sensor:
1452 1452  
1453 -**Specifications of the wind speed sensor:**
1447 +Red:12~~24v
1454 1454  
1455 -Red:  12~~24v
1449 +Yellow:4~~20mA
1456 1456  
1457 -Yellow:  4~~20mA
1451 +Black:GND
1458 1458  
1459 -Black:  GND
1460 1460  
1454 +Connection diagram:
1461 1461  
1462 -**Connection diagram:**
1463 -
1464 1464  [[image:1653357640609-758.png]]
1465 1465  
1466 1466  [[image:1653357648330-671.png||height="155" width="733"]]
... ... @@ -1492,7 +1492,6 @@
1492 1492  
1493 1493  [[image:1653358238933-385.png]]
1494 1494  
1495 -
1496 1496  (((
1497 1497  In PC, User needs to set (% style="color:#4f81bd" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console for LT. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**)(%%) to active it. As shown below:
1498 1498  )))
... ... @@ -1499,7 +1499,6 @@
1499 1499  
1500 1500  [[image:1653358355238-883.png]]
1501 1501  
1502 -
1503 1503  (((
1504 1504  More detail AT Command manual can be found at [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
1505 1505  )))
... ... @@ -1697,9 +1697,7 @@
1697 1697  === 4.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
1698 1698  
1699 1699  (((
1700 -
1701 -
1702 -**If device has not joined network yet:**
1690 +If device has not joined network yet:
1703 1703  )))
1704 1704  
1705 1705  (((
... ... @@ -1724,7 +1724,7 @@
1724 1724  
1725 1725  
1726 1726  (((
1727 -**If device already joined network:**
1715 +If device already joined network:
1728 1728  )))
1729 1729  
1730 1730  (((
... ... @@ -1742,9 +1742,7 @@
1742 1742  === 4.2.2 Single-channel ABP mode (Use with LG01/LG02) ===
1743 1743  
1744 1744  (((
1745 -
1746 -
1747 -(% style="background-color:#dcdcdc" %)123456(%%)  Enter Password to have AT access.
1733 +(% style="background-color:#dcdcdc" %) 123456(%%)  Enter Password to have AT access.
1748 1748  )))
1749 1749  
1750 1750  (((
... ... @@ -1999,6 +1999,7 @@
1999 1999  * (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865
2000 2000  * (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779
2001 2001  
1988 +
2002 2002  = 8. Packing Info =
2003 2003  
2004 2004  
... ... @@ -2016,6 +2016,7 @@
2016 2016  * Package Size / pcs : 14.5 x 8 x 5 cm
2017 2017  * Weight / pcs : 170g
2018 2018  
2006 +
2019 2019  = 9. Support =
2020 2020  
2021 2021  * (((
... ... @@ -2025,6 +2025,7 @@
2025 2025  Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
2026 2026  )))
2027 2027  
2016 +
2028 2028  = 10. Reference​​​​​ =
2029 2029  
2030 2030  * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0