... ... @@ -1332,7 +1332,7 @@
1332 1332  )))
1333 1333  
1334 1334  (((
1335 -(% style="color:blue" %)**Example1**(%%): Connect to a Low active sensor.
1335 +**Example1**: Connect to a Low active sensor.
1336 1336  )))
1337 1337  
1338 1338  (((
... ... @@ -1363,7 +1363,7 @@
1363 1363  )))
1364 1364  
1365 1365  (((
1366 -(% style="color:blue" %)**Example2**(%%): Connect to a High active sensor.
1366 +**Example2**: Connect to a High active sensor.
1367 1367  )))
1368 1368  
1369 1369  (((
... ... @@ -1394,7 +1394,7 @@
1394 1394  )))
1395 1395  
1396 1396  (((
1397 -(% style="color:blue" %)**Example3**(%%): Connect to a 220v high active sensor.
1397 +**Example3**: Connect to a 220v high active sensor.
1398 1398  )))
1399 1399  
1400 1400  (((
... ... @@ -1434,9 +1434,8 @@
1434 1434  
1435 1435  The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is:
1436 1436  
1437 +**AC2 = (IN2 voltage )/12**
1437 1437  
1438 -(% style="color:blue" %)**AC2 = (IN2 voltage )/12**
1439 -
1440 1440  [[image:1653357592296-182.png]]
1441 1441  
1442 1442  Example to connect a 4~~20mA sensor
... ... @@ -1443,18 +1443,17 @@
1443 1443  
1444 1444  We take the wind speed sensor as an example for reference only.
1445 1445  
1445 +Specifications of the wind speed sensor:
1446 1446  
1447 -**Specifications of the wind speed sensor:**
1447 +Red:12~~24v
1448 1448  
1449 -Red:  12~~24v
1449 +Yellow:4~~20mA
1450 1450  
1451 -Yellow:  4~~20mA
1451 +Black:GND
1452 1452  
1453 -Black:  GND
1454 1454  
1454 +Connection diagram:
1455 1455  
1456 -**Connection diagram:**
1457 -
1458 1458  [[image:1653357640609-758.png]]
1459 1459  
1460 1460  [[image:1653357648330-671.png||height="155" width="733"]]
... ... @@ -1486,7 +1486,6 @@
1486 1486  
1487 1487  [[image:1653358238933-385.png]]
1488 1488  
1489 -
1490 1490  (((
1491 1491  In PC, User needs to set (% style="color:#4f81bd" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console for LT. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**)(%%) to active it. As shown below:
1492 1492  )))
... ... @@ -1493,7 +1493,6 @@
1493 1493  
1494 1494  [[image:1653358355238-883.png]]
1495 1495  
1496 -
1497 1497  (((
1498 1498  More detail AT Command manual can be found at [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
1499 1499  )))
... ... @@ -1691,9 +1691,7 @@
1691 1691  === 4.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
1692 1692  
1693 1693  (((
1694 -
1695 -
1696 -**If device has not joined network yet:**
1690 +If device has not joined network yet:
1697 1697  )))
1698 1698  
1699 1699  (((
... ... @@ -1718,7 +1718,7 @@
1718 1718  
1719 1719  
1720 1720  (((
1721 -**If device already joined network:**
1715 +If device already joined network:
1722 1722  )))
1723 1723  
1724 1724  (((
... ... @@ -1736,9 +1736,7 @@
1736 1736  === 4.2.2 Single-channel ABP mode (Use with LG01/LG02) ===
1737 1737  
1738 1738  (((
1739 -
1740 -
1741 -(% style="background-color:#dcdcdc" %)123456(%%)  Enter Password to have AT access.
1733 +(% style="background-color:#dcdcdc" %) 123456(%%)   Enter Password to have AT access.
1742 1742  )))
1743 1743  
1744 1744  (((
... ... @@ -1746,7 +1746,7 @@
1746 1746  )))
1747 1747  
1748 1748  (((
1749 -(% style="background-color:#dcdcdc" %) 123456(%%)  Enter Password to have AT access.
1741 +(% style="background-color:#dcdcdc" %) 123456(%%)   Enter Password to have AT access.
1750 1750  )))
1751 1751  
1752 1752  (((
... ... @@ -1754,41 +1754,39 @@
1754 1754  )))
1755 1755  
1756 1756  (((
1757 -(% style="background-color:#dcdcdc" %) AT+NJM=0(%%)  Set to ABP mode
1749 +(% style="background-color:#dcdcdc" %) AT+NJM=0(%%) Set to ABP mode
1758 1758  )))
1759 1759  
1760 1760  (((
1761 -(% style="background-color:#dcdcdc" %) AT+ADR=0(%%)  Set the Adaptive Data Rate Off
1753 +(% style="background-color:#dcdcdc" %) AT+ADR=0(%%) Set the Adaptive Data Rate Off
1762 1762  )))
1763 1763  
1764 1764  (((
1765 -(% style="background-color:#dcdcdc" %) AT+DR=5(%%)  Set Data Rate
1757 +(% style="background-color:#dcdcdc" %) AT+DR=5(%%)  Set Data Rate
1766 1766  )))
1767 1767  
1768 1768  (((
1769 -(% style="background-color:#dcdcdc" %) AT+TDC=60000(%%)  Set transmit interval to 60 seconds
1761 +(% style="background-color:#dcdcdc" %) AT+TDC=60000(%%)  Set transmit interval to 60 seconds
1770 1770  )))
1771 1771  
1772 1772  (((
1773 -(% style="background-color:#dcdcdc" %) AT+CHS=868400000(%%)  Set transmit frequency to 868.4Mhz
1765 +(% style="background-color:#dcdcdc" %) AT+CHS=868400000(%%) Set transmit frequency to 868.4Mhz
1774 1774  )))
1775 1775  
1776 1776  (((
1777 -(% style="background-color:#dcdcdc" %) AT+RX2FQ=868400000(%%)  Set RX2Frequency to 868.4Mhz (according to the result from server)
1769 +(% style="background-color:#dcdcdc" %) AT+RX2FQ=868400000(%%) Set RX2Frequency to 868.4Mhz (according to the result from server)
1778 1778  )))
1779 1779  
1780 1780  (((
1781 -(% style="background-color:#dcdcdc" %) AT+RX2DR=5(%%)  Set RX2DR to match the downlink DR from server. see below
1773 +(% style="background-color:#dcdcdc" %) AT+RX2DR=5(%%)  Set RX2DR to match the downlink DR from server. see below
1782 1782  )))
1783 1783  
1784 1784  (((
1785 -(% style="background-color:#dcdcdc" %) AT+DADDR=26 01 1A F1 (%%) Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1777 +(% style="background-color:#dcdcdc" %) AT+DADDR=26 01 1A F1 (%%)Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1786 1786  )))
1787 1787  
1788 1788  (((
1789 -(% style="background-color:#dcdcdc" %) ATZ         (%%) Reset MCU
1790 -
1791 -
1781 +(% style="background-color:#dcdcdc" %) ATZ         (%%) Reset MCU
1792 1792  )))
1793 1793  
1794 1794  (((
... ... @@ -1811,6 +1811,7 @@
1811 1811  )))
1812 1812  
1813 1813  
1804 +
1814 1814  === 4.2.3 Change to Class A ===
1815 1815  
1816 1816  If sensor JOINED
... ... @@ -1822,7 +1822,6 @@
1822 1822  
1823 1823  == 5.1 How to upgrade the image? ==
1824 1824  
1825 -
1826 1826  The LT LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to LT to:
1827 1827  
1828 1828  * Support new features
... ... @@ -1850,7 +1850,6 @@
1850 1850  
1851 1851  [[image:image-20220524104033-15.png]]
1852 1852  
1853 -
1854 1854  (% style="color:red" %)**Notice**(%%): In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:
1855 1855  
1856 1856  [[image:1653360054704-518.png||height="186" width="745"]]
... ... @@ -1993,6 +1993,7 @@
1993 1993  * (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865
1994 1994  * (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779
1995 1995  
1985 +
1996 1996  = 8. Packing Info =
1997 1997  
1998 1998  
... ... @@ -2010,6 +2010,7 @@
2010 2010  * Package Size / pcs : 14.5 x 8 x 5 cm
2011 2011  * Weight / pcs : 170g
2012 2012  
2003 +
2013 2013  = 9. Support =
2014 2014  
2015 2015  * (((
... ... @@ -2019,6 +2019,7 @@
2019 2019  Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
2020 2020  )))
2021 2021  
2013 +
2022 2022  = 10. Reference​​​​​ =
2023 2023  
2024 2024  * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved