Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -75,6 +75,7 @@ 75 75 ))) 76 76 ))) 77 77 78 + 78 78 ((( 79 79 **Interface for Model: LT22222-L:** 80 80 ))) ... ... @@ -98,6 +98,7 @@ 98 98 Power Input 7~~ 24V DC. 99 99 ))) 100 100 102 + 101 101 ((( 102 102 **LoRa Spec:** 103 103 ))) ... ... @@ -162,6 +162,8 @@ 162 162 163 163 ))) 164 164 167 + 168 + 165 165 == 1.3 Features == 166 166 167 167 * LoRaWAN Class A & Class C protocol ... ... @@ -172,6 +172,8 @@ 172 172 * Firmware upgradable via program port 173 173 * Counting 174 174 179 + 180 + 175 175 == 1.4 Applications == 176 176 177 177 * Smart Buildings & Home Automation ... ... @@ -181,6 +181,8 @@ 181 181 * Smart Cities 182 182 * Smart Factory 183 183 190 + 191 + 184 184 == 1.5 Hardware Variants == 185 185 186 186 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -194,6 +194,8 @@ 194 194 * 1 x Counting Port 195 195 ))) 196 196 205 + 206 + 197 197 = 2. Power ON Device = 198 198 199 199 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -275,6 +275,8 @@ 275 275 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 276 276 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 277 277 288 + 289 + 278 278 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 279 279 280 280 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -310,6 +310,7 @@ 310 310 * [1] RO1 relay channel is close and the RO1 LED is ON. 311 311 * [0] RO2 relay channel is open and RO2 LED is OFF; 312 312 325 + 313 313 **LT22222-L:** 314 314 315 315 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -325,6 +325,8 @@ 325 325 ** DO1 is high in case there is load between DO1 and V+. 326 326 ** DO1 LED is off in both case 327 327 341 + 342 + 328 328 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 329 329 330 330 **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins. ... ... @@ -739,6 +739,8 @@ 739 739 740 740 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 741 741 757 + 758 + 742 742 === 3.4.1 Common Commands === 743 743 744 744 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -1084,7 +1084,6 @@ 1084 1084 DO1 pin no action, DO2 pin set low, DO3 pin set high, last 2 seconds, then DO1 pin no action, DO2 pin set high, DO3 pin set low 1085 1085 1086 1086 1087 - 1088 1088 === 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 === 1089 1089 1090 1090 * AT Command: ... ... @@ -1113,7 +1113,6 @@ 1113 1113 Device will upload a packet if downlink code executes successfully. 1114 1114 1115 1115 1116 - 1117 1117 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1118 1118 1119 1119 * AT Command: ... ... @@ -1164,7 +1164,6 @@ 1164 1164 Relay 1 & relay2 will change to NC, last 2 seconds, then both change to NO. 1165 1165 1166 1166 1167 - 1168 1168 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1169 1169 1170 1170 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] ... ... @@ -1184,7 +1184,6 @@ 1184 1184 ))) 1185 1185 1186 1186 1187 - 1188 1188 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1189 1189 1190 1190 * AT Command: ... ... @@ -1210,7 +1210,6 @@ 1210 1210 ))) 1211 1211 1212 1212 1213 - 1214 1214 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1215 1215 1216 1216 Clear counting for counting mode ... ... @@ -1230,7 +1230,6 @@ 1230 1230 ))) 1231 1231 1232 1232 1233 - 1234 1234 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1235 1235 1236 1236 * AT Command: ... ... @@ -1253,8 +1253,6 @@ 1253 1253 1254 1254 ))) 1255 1255 1256 - 1257 - 1258 1258 == 3.5 Integrate with Mydevice == 1259 1259 1260 1260 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: ... ... @@ -1296,7 +1296,6 @@ 1296 1296 [[image:image-20220524094909-5.png||height="341" width="734"]] 1297 1297 1298 1298 1299 - 1300 1300 == 3.6 Interface Detail == 1301 1301 1302 1302 === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) === ... ... @@ -1306,7 +1306,6 @@ 1306 1306 [[image:1653356991268-289.png]] 1307 1307 1308 1308 1309 - 1310 1310 === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) === 1311 1311 1312 1312 ((( ... ... @@ -1421,7 +1421,6 @@ 1421 1421 ))) 1422 1422 1423 1423 1424 - 1425 1425 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1426 1426 1427 1427 NPN output: GND or Float. Max voltage can apply to output pin is 36v. ... ... @@ -1429,7 +1429,6 @@ 1429 1429 [[image:1653357531600-905.png]] 1430 1430 1431 1431 1432 - 1433 1433 === 3.6.4 Analog Input Interface === 1434 1434 1435 1435 The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is: ... ... @@ -1442,24 +1442,22 @@ 1442 1442 1443 1443 We take the wind speed sensor as an example for reference only. 1444 1444 1450 +Specifications of the wind speed sensor: 1445 1445 1446 - **Specifications of the windspeed sensor:**1452 +Red:12~~24v 1447 1447 1448 - Red:12~~24v1454 +Yellow:4~~20mA 1449 1449 1450 - Yellow:4~~20mA1456 +Black:GND 1451 1451 1452 -Black: GND 1453 1453 1459 +Connection diagram: 1454 1454 1455 -**Connection diagram:** 1456 - 1457 1457 [[image:1653357640609-758.png]] 1458 1458 1459 1459 [[image:1653357648330-671.png||height="155" width="733"]] 1460 1460 1461 1461 1462 - 1463 1463 === 3.6.5 Relay Output === 1464 1464 1465 1465 ((( ... ... @@ -1471,7 +1471,6 @@ 1471 1471 [[image:image-20220524100215-10.png||height="382" width="723"]] 1472 1472 1473 1473 1474 - 1475 1475 == 3.7 LEDs Indicators == 1476 1476 1477 1477 [[image:image-20220524100748-11.png]] ... ... @@ -1485,7 +1485,6 @@ 1485 1485 1486 1486 [[image:1653358238933-385.png]] 1487 1487 1488 - 1489 1489 ((( 1490 1490 In PC, User needs to set (% style="color:#4f81bd" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console for LT. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**)(%%) to active it. As shown below: 1491 1491 ))) ... ... @@ -1492,7 +1492,6 @@ 1492 1492 1493 1493 [[image:1653358355238-883.png]] 1494 1494 1495 - 1496 1496 ((( 1497 1497 More detail AT Command manual can be found at [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 1498 1498 ))) ... ... @@ -1683,16 +1683,12 @@ 1683 1683 1684 1684 ))) 1685 1685 1686 - 1687 - 1688 1688 == 4.2 Common AT Command Sequence == 1689 1689 1690 1690 === 4.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1691 1691 1692 1692 ((( 1693 - 1694 - 1695 -**If device has not joined network yet:** 1691 +If device has not joined network yet: 1696 1696 ))) 1697 1697 1698 1698 ((( ... ... @@ -1717,7 +1717,7 @@ 1717 1717 1718 1718 1719 1719 ((( 1720 - **If device already joined network:**1716 +If device already joined network: 1721 1721 ))) 1722 1722 1723 1723 ((( ... ... @@ -1730,14 +1730,10 @@ 1730 1730 1731 1731 ))) 1732 1732 1733 - 1734 - 1735 1735 === 4.2.2 Single-channel ABP mode (Use with LG01/LG02) === 1736 1736 1737 1737 ((( 1738 - 1739 - 1740 -(% style="background-color:#dcdcdc" %)123456(%%) Enter Password to have AT access. 1732 +(% style="background-color:#dcdcdc" %) 123456(%%) Enter Password to have AT access. 1741 1741 ))) 1742 1742 1743 1743 ((( ... ... @@ -1745,7 +1745,7 @@ 1745 1745 ))) 1746 1746 1747 1747 ((( 1748 -(% style="background-color:#dcdcdc" %) 123456(%%) 1740 +(% style="background-color:#dcdcdc" %) 123456(%%) Enter Password to have AT access. 1749 1749 ))) 1750 1750 1751 1751 ((( ... ... @@ -1753,41 +1753,39 @@ 1753 1753 ))) 1754 1754 1755 1755 ((( 1756 -(% style="background-color:#dcdcdc" %) AT+NJM=0(%%) 1748 +(% style="background-color:#dcdcdc" %) AT+NJM=0(%%) Set to ABP mode 1757 1757 ))) 1758 1758 1759 1759 ((( 1760 -(% style="background-color:#dcdcdc" %) AT+ADR=0(%%) 1752 +(% style="background-color:#dcdcdc" %) AT+ADR=0(%%) Set the Adaptive Data Rate Off 1761 1761 ))) 1762 1762 1763 1763 ((( 1764 -(% style="background-color:#dcdcdc" %) AT+DR=5(%%) 1756 +(% style="background-color:#dcdcdc" %) AT+DR=5(%%) Set Data Rate 1765 1765 ))) 1766 1766 1767 1767 ((( 1768 -(% style="background-color:#dcdcdc" %) AT+TDC=60000(%%) 1760 +(% style="background-color:#dcdcdc" %) AT+TDC=60000(%%) Set transmit interval to 60 seconds 1769 1769 ))) 1770 1770 1771 1771 ((( 1772 -(% style="background-color:#dcdcdc" %) AT+CHS=868400000(%%) 1764 +(% style="background-color:#dcdcdc" %) AT+CHS=868400000(%%) Set transmit frequency to 868.4Mhz 1773 1773 ))) 1774 1774 1775 1775 ((( 1776 -(% style="background-color:#dcdcdc" %) AT+RX2FQ=868400000(%%) 1768 +(% style="background-color:#dcdcdc" %) AT+RX2FQ=868400000(%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 1777 1777 ))) 1778 1778 1779 1779 ((( 1780 -(% style="background-color:#dcdcdc" %) AT+RX2DR=5(%%) 1772 +(% style="background-color:#dcdcdc" %) AT+RX2DR=5(%%) Set RX2DR to match the downlink DR from server. see below 1781 1781 ))) 1782 1782 1783 1783 ((( 1784 -(% style="background-color:#dcdcdc" %) AT+DADDR=26 01 1A F1 (%%) 1776 +(% style="background-color:#dcdcdc" %) AT+DADDR=26 01 1A F1 (%%)Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1785 1785 ))) 1786 1786 1787 1787 ((( 1788 -(% style="background-color:#dcdcdc" %) ATZ (%%) Reset MCU 1789 - 1790 - 1780 +(% style="background-color:#dcdcdc" %) ATZ (%%) Reset MCU 1791 1791 ))) 1792 1792 1793 1793 ((( ... ... @@ -1809,7 +1809,6 @@ 1809 1809 1810 1810 ))) 1811 1811 1812 - 1813 1813 === 4.2.3 Change to Class A === 1814 1814 1815 1815 If sensor JOINED ... ... @@ -1821,25 +1821,19 @@ 1821 1821 1822 1822 == 5.1 How to upgrade the image? == 1823 1823 1824 - 1825 1825 The LT LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to LT to: 1826 1826 1827 1827 * Support new features 1828 1828 * For bug fix 1829 1829 * Change LoRaWAN bands. 1830 - 1831 1831 Below shows the hardware connection for how to upload an image to the LT: 1819 +* [[image:1653359603330-121.png]] 1832 1832 1833 -[[image:1653359603330-121.png]] 1834 - 1835 - 1836 1836 ((( 1837 -(% style="color:blue" %)**Step1**(%%)**:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1838 -(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 1839 -(% style="color:blue" %)**Step3**(%%)**:** Open flashloader; choose the correct COM port to update. 1840 - 1841 - 1842 -(% style="color:blue" %)**For LT-22222-L**(%%): 1822 +**Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1823 +**Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 1824 +**Step3: **Open flashloader; choose the correct COM port to update. 1825 +**For LT-22222-L**: 1843 1843 Hold down the PRO button and then momentarily press the RST reset button and the **DO1 led** will change from OFF to ON. When **DO1 LED** is on, it means the device is in download mode. 1844 1844 ))) 1845 1845 ... ... @@ -1849,7 +1849,6 @@ 1849 1849 1850 1850 [[image:image-20220524104033-15.png]] 1851 1851 1852 - 1853 1853 (% style="color:red" %)**Notice**(%%): In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is: 1854 1854 1855 1855 [[image:1653360054704-518.png||height="186" width="745"]] ... ... @@ -1857,8 +1857,6 @@ 1857 1857 1858 1858 ((( 1859 1859 ((( 1860 - 1861 - 1862 1862 == 5.2 How to change the LoRa Frequency Bands/Region? == 1863 1863 ))) 1864 1864 ))) ... ... @@ -1865,11 +1865,11 @@ 1865 1865 1866 1866 ((( 1867 1867 User can follow the introduction for [[how to upgrade image>>||anchor="H5.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download. 1868 -))) 1869 1869 1870 -((( 1871 1871 1850 +))) 1872 1872 1852 +((( 1873 1873 == 5.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? == 1874 1874 ))) 1875 1875 ... ... @@ -1882,8 +1882,6 @@ 1882 1882 ((( 1883 1883 ((( 1884 1884 Assume we have a LG02 working in the frequency 868400000 now , below is the step. 1885 - 1886 - 1887 1887 ))) 1888 1888 ))) 1889 1889 ... ... @@ -1899,25 +1899,23 @@ 1899 1899 (% style="color:red" %)Note: user just need to make sure above three keys match, User can change either in TTN or Device to make then match. In TTN, NETSKEY and APPSKEY can be configured by user in setting page, but Device Addr is generated by TTN. 1900 1900 ))) 1901 1901 1902 - 1903 1903 ((( 1904 1904 (% style="color:#4f81bd" %)**Step2**(%%)**: **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands: 1905 1905 ))) 1906 1906 1907 1907 ((( 1908 -(% style="background-color:#dcdcdc" %)123456 (%%) 1909 -(% style="background-color:#dcdcdc" %)AT+FDR(%%) 1910 -(% style="background-color:#dcdcdc" %)123456 (%%) 1911 -(% style="background-color:#dcdcdc" %)AT+NJM=0 (%%) 1912 -(% style="background-color:#dcdcdc" %)AT+ADR=0 (%%) 1913 -(% style="background-color:#dcdcdc" %)AT+DR=5 (%%) 1914 -(% style="background-color:#dcdcdc" %)AT+TDC=60000 (%%) 1915 -(% style="background-color:#dcdcdc" %)AT+CHS=868400000(%%) 1916 -(% style="background-color:#dcdcdc" %)AT+DADDR=26 01 1A F1(%%) 1917 -(% style="background-color:#dcdcdc" %)ATZ (%%) 1885 +(% style="background-color:#dcdcdc" %)123456 (%%) Enter Password to have AT access. 1886 +(% style="background-color:#dcdcdc" %)AT+FDR (%%) Reset Parameters to Factory Default, Keys Reserve 1887 +(% style="background-color:#dcdcdc" %)123456 (%%) Enter Password to have AT access. 1888 +(% style="background-color:#dcdcdc" %)AT+NJM=0 (%%)Set to ABP mode 1889 +(% style="background-color:#dcdcdc" %)AT+ADR=0 (%%)Set the Adaptive Data Rate Off 1890 +(% style="background-color:#dcdcdc" %)AT+DR=5 (%%) Set Data Rate (Set AT+DR=3 for 915 band) 1891 +(% style="background-color:#dcdcdc" %)AT+TDC=60000 (%%)Set transmit interval to 60 seconds 1892 +(% style="background-color:#dcdcdc" %)AT+CHS=868400000 (%%)Set transmit frequency to 868.4Mhz 1893 +(% style="background-color:#dcdcdc" %)AT+DADDR=26 01 1A F1(%%) Set Device Address to 26 01 1A F1 1894 +(% style="background-color:#dcdcdc" %)ATZ (%%)Reset MCU 1918 1918 ))) 1919 1919 1920 - 1921 1921 ((( 1922 1922 As shown in below: 1923 1923 ))) ... ... @@ -1934,11 +1934,11 @@ 1934 1934 == 5.5 Can i use point to point communication for LT-22222-L? == 1935 1935 1936 1936 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1937 -))) 1938 1938 1939 -((( 1940 1940 1915 +))) 1941 1941 1917 +((( 1942 1942 = 6. Trouble Shooting = 1943 1943 ))) 1944 1944 ... ... @@ -1950,11 +1950,11 @@ 1950 1950 1951 1951 ((( 1952 1952 Please see this link for how to debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H5.1Howitwork"]] 1953 -))) 1954 1954 1955 -((( 1956 1956 1931 +))) 1957 1957 1933 +((( 1958 1958 == 6.2 Have trouble to upload image. == 1959 1959 ))) 1960 1960 ... ... @@ -1964,7 +1964,9 @@ 1964 1964 1965 1965 ((( 1966 1966 1943 +))) 1967 1967 1945 +((( 1968 1968 == 6.3 Why I can’t join TTN in US915 /AU915 bands? == 1969 1969 ))) 1970 1970 ... ... @@ -1972,58 +1972,147 @@ 1972 1972 It might be about the channels mapping. [[Please see this link for detail>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]] 1973 1973 ))) 1974 1974 1953 +((( 1954 + 1955 +))) 1975 1975 1976 - 1957 +((( 1977 1977 = 7. Order Info = 1959 +))) 1978 1978 1979 - 1961 +((( 1962 +((( 1980 1980 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1964 +))) 1965 +))) 1981 1981 1982 - 1967 +((( 1968 +((( 1983 1983 (% style="color:#4f81bd" %)**XXX:** 1970 +))) 1971 +))) 1984 1984 1985 -* (% style="color:#4f81bd" %)**EU433**(%%): LT with frequency bands EU433 1986 -* (% style="color:#4f81bd" %)**EU868**(%%): LT with frequency bands EU868 1987 -* (% style="color:#4f81bd" %)**KR920**(%%): LT with frequency bands KR920 1988 -* (% style="color:#4f81bd" %)**CN470**(%%): LT with frequency bands CN470 1989 -* (% style="color:#4f81bd" %)**AS923**(%%): LT with frequency bands AS923 1990 -* (% style="color:#4f81bd" %)**AU915**(%%): LT with frequency bands AU915 1991 -* (% style="color:#4f81bd" %)**US915**(%%): LT with frequency bands US915 1992 -* (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865 1993 -* (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779 1973 +((( 1974 +* ((( 1975 +(% style="color:#4f81bd" %)**EU433**(%%): LT with frequency bands EU433 1976 +))) 1977 +))) 1994 1994 1979 +((( 1980 +* ((( 1981 +(% style="color:#4f81bd" %)**EU868**(%%): LT with frequency bands EU868 1982 +))) 1983 +))) 1995 1995 1996 -= 8. Packing Info = 1985 +((( 1986 +* ((( 1987 +(% style="color:#4f81bd" %)**KR920**(%%): LT with frequency bands KR920 1988 +))) 1989 +))) 1997 1997 1991 +((( 1992 +* ((( 1993 +(% style="color:#4f81bd" %)**CN470**(%%): LT with frequency bands CN470 1994 +))) 1995 +))) 1998 1998 1997 +((( 1998 +* ((( 1999 +(% style="color:#4f81bd" %)**AS923**(%%): LT with frequency bands AS923 2000 +))) 2001 +))) 2002 + 2003 +((( 2004 +* ((( 2005 +(% style="color:#4f81bd" %)**AU915**(%%): LT with frequency bands AU915 2006 +))) 2007 +))) 2008 + 2009 +((( 2010 +* ((( 2011 +(% style="color:#4f81bd" %)**US915**(%%): LT with frequency bands US915 2012 +))) 2013 +))) 2014 + 2015 +((( 2016 +* ((( 2017 +(% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865 2018 +))) 2019 +))) 2020 + 2021 +((( 2022 +* ((( 2023 +(% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779 2024 + 2025 + 2026 +))) 2027 + 2028 += 8. Packing Info = 2029 +))) 2030 + 2031 +((( 2032 +((( 1999 1999 **Package Includes**: 2034 +))) 2035 +))) 2000 2000 2037 +((( 2038 +((( 2001 2001 * LT-22222-L I/O Controller x 1 2002 2002 * Stick Antenna for LoRa RF part x 1 2003 2003 * Bracket for controller x1 2004 2004 * Program cable x 1 2043 +))) 2044 +))) 2005 2005 2046 +((( 2047 +((( 2006 2006 **Dimension and weight**: 2049 +))) 2050 +))) 2007 2007 2052 +((( 2053 +((( 2008 2008 * Device Size: 13.5 x 7 x 3 cm 2009 2009 * Device Weight: 105g 2010 2010 * Package Size / pcs : 14.5 x 8 x 5 cm 2011 2011 * Weight / pcs : 170g 2012 2012 2059 + 2060 +))) 2061 +))) 2013 2013 2063 +((( 2014 2014 = 9. Support = 2065 +))) 2015 2015 2016 2016 * ((( 2068 +((( 2017 2017 Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 2018 2018 ))) 2071 +))) 2019 2019 * ((( 2020 -Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 2073 +((( 2074 +Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to 2021 2021 ))) 2076 +))) 2022 2022 2078 +((( 2079 +((( 2080 + [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 2023 2023 2082 + 2083 +))) 2084 + 2085 +((( 2024 2024 = 10. Reference = 2025 2025 2026 -* LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 2088 +* Product Page: 2089 + 2090 +LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 2091 + 2027 2027 * [[Image Download>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]] 2028 2028 * [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 2029 2029 * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]] 2095 +))) 2096 +)))