From version < 77.54 >
edited by Xiaoling
on 2022/06/10 09:07
To version < 77.59 >
edited by Xiaoling
on 2022/06/10 09:11
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1283,16 +1283,21 @@
1283 1283  [[image:1653356838789-523.png||height="337" width="740"]]
1284 1284  
1285 1285  
1286 +
1286 1286  After added, the sensor data arrive TTN, it will also arrive and show in Mydevices.
1287 1287  
1288 1288  [[image:image-20220524094909-1.png||height="335" width="729"]]
1289 1289  
1291 +
1290 1290  [[image:image-20220524094909-2.png||height="337" width="729"]]
1291 1291  
1294 +
1292 1292  [[image:image-20220524094909-3.png||height="338" width="727"]]
1293 1293  
1297 +
1294 1294  [[image:image-20220524094909-4.png||height="339" width="728"]](% style="display:none" %)
1295 1295  
1300 +
1296 1296  [[image:image-20220524094909-5.png||height="341" width="734"]]
1297 1297  
1298 1298  
... ... @@ -1332,7 +1332,7 @@
1332 1332  )))
1333 1333  
1334 1334  (((
1335 -**Example1**: Connect to a Low active sensor.
1340 +(% style="color:blue" %)**Example1**(%%): Connect to a Low active sensor.
1336 1336  )))
1337 1337  
1338 1338  (((
... ... @@ -1363,7 +1363,7 @@
1363 1363  )))
1364 1364  
1365 1365  (((
1366 -**Example2**: Connect to a High active sensor.
1371 +(% style="color:blue" %)**Example2**(%%): Connect to a High active sensor.
1367 1367  )))
1368 1368  
1369 1369  (((
... ... @@ -1394,7 +1394,7 @@
1394 1394  )))
1395 1395  
1396 1396  (((
1397 -**Example3**: Connect to a 220v high active sensor.
1402 +(% style="color:blue" %)**Example3**(%%): Connect to a 220v high active sensor.
1398 1398  )))
1399 1399  
1400 1400  (((
... ... @@ -1434,8 +1434,9 @@
1434 1434  
1435 1435  The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is:
1436 1436  
1437 -**AC2 = (IN2 voltage )/12**
1438 1438  
1443 +(% style="color:blue" %)**AC2 = (IN2 voltage )/12**
1444 +
1439 1439  [[image:1653357592296-182.png]]
1440 1440  
1441 1441  Example to connect a 4~~20mA sensor
... ... @@ -1442,17 +1442,18 @@
1442 1442  
1443 1443  We take the wind speed sensor as an example for reference only.
1444 1444  
1445 -Specifications of the wind speed sensor:
1446 1446  
1447 -Red:12~~24v
1452 +**Specifications of the wind speed sensor:**
1448 1448  
1449 -Yellow:4~~20mA
1454 +Red:  12~~24v
1450 1450  
1451 -Black:GND
1456 +Yellow:  4~~20mA
1452 1452  
1458 +Black:  GND
1453 1453  
1454 -Connection diagram:
1455 1455  
1461 +**Connection diagram:**
1462 +
1456 1456  [[image:1653357640609-758.png]]
1457 1457  
1458 1458  [[image:1653357648330-671.png||height="155" width="733"]]
... ... @@ -1991,7 +1991,6 @@
1991 1991  * (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865
1992 1992  * (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779
1993 1993  
1994 -
1995 1995  = 8. Packing Info =
1996 1996  
1997 1997  
... ... @@ -2009,7 +2009,6 @@
2009 2009  * Package Size / pcs : 14.5 x 8 x 5 cm
2010 2010  * Weight / pcs : 170g
2011 2011  
2012 -
2013 2013  = 9. Support =
2014 2014  
2015 2015  * (((
... ... @@ -2019,7 +2019,6 @@
2019 2019  Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
2020 2020  )))
2021 2021  
2022 -
2023 2023  = 10. Reference​​​​​ =
2024 2024  
2025 2025  * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0