760 760  
761 761  **Example: **AT+TDC=30000. Means set interval to 30 seconds
762 762  
763 +
763 763  * Downlink Payload (prefix 0x01):
764 764  
765 765  (% class="box infomessage" %)
... ... @@ -782,6 +782,7 @@
782 782  
783 783  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
784 784  
786 +
785 785  * Downlink Payload (prefix 0x0A):
786 786  
787 787  (% class="box infomessage" %)
... ... @@ -797,6 +797,7 @@
797 797  
798 798  There is no AT Command to poll uplink
799 799  
802 +
800 800  * Downlink Payload (prefix 0x08):
801 801  
802 802  (% class="box infomessage" %)
... ... @@ -823,6 +823,7 @@
823 823  
824 824  0: Disable Trigger Mode
825 825  
829 +
826 826  * Downlink Payload (prefix 0x0A 06):
827 827  
828 828  (% class="box infomessage" %)
... ... @@ -840,6 +840,7 @@
840 840  
841 841  There is no AT Command for this feature.
842 842  
847 +
843 843  * Downlink Payload (prefix 0x AB 06):
844 844  
845 845  (% class="box infomessage" %)
... ... @@ -860,6 +860,7 @@
860 860  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
861 861  )))
862 862  
868 +
863 863  **Example:**
864 864  
865 865  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -888,10 +888,12 @@
888 888  
889 889  b : delay timing.
890 890  
897 +
891 891  **Example:**
892 892  
893 893  AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms )
894 894  
902 +
895 895  * Downlink Payload (prefix 0x09 01 ):
896 896  
897 897  (% class="box infomessage" %)
... ... @@ -916,10 +916,12 @@
916 916  
917 917  b : delay timing.
918 918  
927 +
919 919  **Example:**
920 920  
921 921  AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms )
922 922  
932 +
923 923  * Downlink Payload (prefix 0x09 02 ):
924 924  
925 925  (% class="box infomessage" %)
... ... @@ -940,6 +940,7 @@
940 940  **AT+ACLIM. **
941 941  )))
942 942  
953 +
943 943  * Downlink Payload (prefix 0xAA 01 ):
944 944  
945 945  (% class="box infomessage" %)
... ... @@ -960,6 +960,7 @@
960 960  **AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
961 961  )))
962 962  
974 +
963 963  * Downlink Payload (prefix 0xAA 00 ):
964 964  
965 965  (% class="box infomessage" %)
... ... @@ -980,6 +980,7 @@
980 980  **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.**
981 981  )))
982 982  
995 +
983 983  * Downlink Payload (prefix 0xAC ):
984 984  
985 985  (% class="box infomessage" %)
... ... @@ -995,6 +995,7 @@
995 995  
996 996  There is no AT Command to control Digital Output
997 997  
1011 +
998 998  * Downlink Payload (prefix 0x02):
999 999  
1000 1000  (% class="box infomessage" %)
... ... @@ -1028,6 +1028,7 @@
1028 1028  
1029 1029  There is no AT Command to control Digital Output
1030 1030  
1045 +
1031 1031  * Downlink Payload (prefix 0xA9):
1032 1032  
1033 1033  (% class="box infomessage" %)
... ... @@ -1047,18 +1047,22 @@
1047 1047  
1048 1048  00: DO pins will change to an inverter state after timeout 
1049 1049  
1065 +
1050 1050  (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status:
1051 1051  
1052 1052  [[image:image-20220524093238-6.png]]
1053 1053  
1070 +
1054 1054  (% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status:
1055 1055  
1056 1056  [[image:image-20220524093328-7.png]]
1057 1057  
1075 +
1058 1058  (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status:
1059 1059  
1060 1060  [[image:image-20220524093351-8.png]]
1061 1061  
1080 +
1062 1062  (% style="color:#4f81bd" %)**Sixth and Seventh Byte**:
1063 1063  
1064 1064   Latching time. Unit: ms
... ... @@ -1065,6 +1065,7 @@
1065 1065  
1066 1066  Device will upload a packet if downlink code executes successfully.
1067 1067  
1087 +
1068 1068  **Example payload:**
1069 1069  
1070 1070  **~1. A9 01 01 01 01 07 D0**
... ... @@ -1091,6 +1091,7 @@
1091 1091  
1092 1092  There is no AT Command to control Relay Output
1093 1093  
1114 +
1094 1094  * Downlink Payload (prefix 0x03):
1095 1095  
1096 1096  (% class="box infomessage" %)
... ... @@ -1120,6 +1120,7 @@
1120 1120  
1121 1121  There is no AT Command to control Relay Output
1122 1122  
1144 +
1123 1123  * Downlink Payload (prefix 0x05):
1124 1124  
1125 1125  (% class="box infomessage" %)
... ... @@ -1137,14 +1137,17 @@
1137 1137  
1138 1138  00: Relays will change to an inverter state after timeout
1139 1139  
1162 +
1140 1140  (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status:
1141 1141  
1142 1142  [[image:image-20220524093831-10.png]]
1143 1143  
1167 +
1144 1144  (% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms
1145 1145  
1146 1146  Device will upload a packet if downlink code executes successfully.
1147 1147  
1172 +
1148 1148  **Example payload:**
1149 1149  
1150 1150  **~1. 05 01 11 07 D0**
... ... @@ -1176,6 +1176,7 @@
1176 1176  **AT+VOLMAX    ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]**
1177 1177  )))
1178 1178  
1204 +
1179 1179  * Downlink Payload (prefix 0xA5):
1180 1180  
1181 1181  (% class="box infomessage" %)
... ... @@ -1202,6 +1202,7 @@
1202 1202  
1203 1203  Bb cc dd ee: number to be set
1204 1204  
1231 +
1205 1205  * Downlink Payload (prefix 0xA8):
1206 1206  
1207 1207  (% class="box infomessage" %)
... ... @@ -1254,17 +1254,16 @@
1254 1254  )))
1255 1255  
1256 1256  
1257 -
1258 1258  == 3.5 Integrate with Mydevice ==
1259 1259  
1260 1260  Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps:
1261 1261  
1262 1262  (((
1263 -**Step 1**: Be sure that your device is programmed and properly connected to the network at this time.
1289 +(% style="color:blue" %)**Step 1**(%%): Be sure that your device is programmed and properly connected to the network at this time.
1264 1264  )))
1265 1265  
1266 1266  (((
1267 -**Step 2**: To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps:
1293 +(% style="color:blue" %)**Step 2**(%%): To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps:
1268 1268  )))
1269 1269  
1270 1270  [[image:1653356737703-362.png||height="232" width="732"]]
... ... @@ -1271,12 +1271,13 @@
1271 1271  
1272 1272  [[image:image-20220524094641-11.png||height="390" width="723"]]
1273 1273  
1300 +
1274 1274  [[image:image-20220524094641-12.png||height="402" width="718"]]
1275 1275  
1276 1276  
1277 -**Step 3**: Create an account or log in Mydevices.
1304 +(% style="color:blue" %)**Step 3**(%%): Create an account or log in Mydevices.
1278 1278  
1279 -**Step 4**: Search LT-22222-L(for both LT-22222-L / LT-33222-L) and add DevEUI.(% style="display:none" %)
1306 +(% style="color:blue" %)**Step 4**(%%): Search LT-22222-L(for both LT-22222-L / LT-33222-L) and add DevEUI.(% style="display:none" %)
1280 1280  
1281 1281  Search under The things network
1282 1282  
... ... @@ -1283,16 +1283,21 @@
1283 1283  [[image:1653356838789-523.png||height="337" width="740"]]
1284 1284  
1285 1285  
1313 +
1286 1286  After added, the sensor data arrive TTN, it will also arrive and show in Mydevices.
1287 1287  
1288 1288  [[image:image-20220524094909-1.png||height="335" width="729"]]
1289 1289  
1318 +
1290 1290  [[image:image-20220524094909-2.png||height="337" width="729"]]
1291 1291  
1321 +
1292 1292  [[image:image-20220524094909-3.png||height="338" width="727"]]
1293 1293  
1324 +
1294 1294  [[image:image-20220524094909-4.png||height="339" width="728"]](% style="display:none" %)
1295 1295  
1327 +
1296 1296  [[image:image-20220524094909-5.png||height="341" width="734"]]
1297 1297  
1298 1298  
... ... @@ -1332,7 +1332,7 @@
1332 1332  )))
1333 1333  
1334 1334  (((
1335 -**Example1**: Connect to a Low active sensor.
1367 +(% style="color:blue" %)**Example1**(%%): Connect to a Low active sensor.
1336 1336  )))
1337 1337  
1338 1338  (((
... ... @@ -1363,7 +1363,7 @@
1363 1363  )))
1364 1364  
1365 1365  (((
1366 -**Example2**: Connect to a High active sensor.
1398 +(% style="color:blue" %)**Example2**(%%): Connect to a High active sensor.
1367 1367  )))
1368 1368  
1369 1369  (((
... ... @@ -1394,7 +1394,7 @@
1394 1394  )))
1395 1395  
1396 1396  (((
1397 -**Example3**: Connect to a 220v high active sensor.
1429 +(% style="color:blue" %)**Example3**(%%): Connect to a 220v high active sensor.
1398 1398  )))
1399 1399  
1400 1400  (((
... ... @@ -1434,8 +1434,9 @@
1434 1434  
1435 1435  The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is:
1436 1436  
1437 -**AC2 = (IN2 voltage )/12**
1438 1438  
1470 +(% style="color:blue" %)**AC2 = (IN2 voltage )/12**
1471 +
1439 1439  [[image:1653357592296-182.png]]
1440 1440  
1441 1441  Example to connect a 4~~20mA sensor
... ... @@ -1442,17 +1442,18 @@
1442 1442  
1443 1443  We take the wind speed sensor as an example for reference only.
1444 1444  
1445 -Specifications of the wind speed sensor:
1446 1446  
1447 -Red:12~~24v
1479 +**Specifications of the wind speed sensor:**
1448 1448  
1449 -Yellow:4~~20mA
1481 +Red:  12~~24v
1450 1450  
1451 -Black:GND
1483 +Yellow:  4~~20mA
1452 1452  
1485 +Black:  GND
1453 1453  
1454 -Connection diagram:
1455 1455  
1488 +**Connection diagram:**
1489 +
1456 1456  [[image:1653357640609-758.png]]
1457 1457  
1458 1458  [[image:1653357648330-671.png||height="155" width="733"]]
... ... @@ -1484,6 +1484,7 @@
1484 1484  
1485 1485  [[image:1653358238933-385.png]]
1486 1486  
1521 +
1487 1487  (((
1488 1488  In PC, User needs to set (% style="color:#4f81bd" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console for LT. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**)(%%) to active it. As shown below:
1489 1489  )))
... ... @@ -1490,6 +1490,7 @@
1490 1490  
1491 1491  [[image:1653358355238-883.png]]
1492 1492  
1528 +
1493 1493  (((
1494 1494  More detail AT Command manual can be found at [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
1495 1495  )))
... ... @@ -1687,7 +1687,9 @@
1687 1687  === 4.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
1688 1688  
1689 1689  (((
1690 -If device has not joined network yet:
1726 +
1727 +
1728 +**If device has not joined network yet:**
1691 1691  )))
1692 1692  
1693 1693  (((
... ... @@ -1712,7 +1712,7 @@
1712 1712  
1713 1713  
1714 1714  (((
1715 -If device already joined network:
1753 +**If device already joined network:**
1716 1716  )))
1717 1717  
1718 1718  (((
... ... @@ -1730,7 +1730,9 @@
1730 1730  === 4.2.2 Single-channel ABP mode (Use with LG01/LG02) ===
1731 1731  
1732 1732  (((
1733 -(% style="background-color:#dcdcdc" %) 123456(%%)   Enter Password to have AT access.
1771 +
1772 +
1773 +(% style="background-color:#dcdcdc" %)123456(%%)  Enter Password to have AT access.
1734 1734  )))
1735 1735  
1736 1736  (((
... ... @@ -1738,7 +1738,7 @@
1738 1738  )))
1739 1739  
1740 1740  (((
1741 -(% style="background-color:#dcdcdc" %) 123456(%%)   Enter Password to have AT access.
1781 +(% style="background-color:#dcdcdc" %) 123456(%%)  Enter Password to have AT access.
1742 1742  )))
1743 1743  
1744 1744  (((
... ... @@ -1746,39 +1746,41 @@
1746 1746  )))
1747 1747  
1748 1748  (((
1749 -(% style="background-color:#dcdcdc" %) AT+NJM=0(%%) Set to ABP mode
1789 +(% style="background-color:#dcdcdc" %) AT+NJM=0(%%)  Set to ABP mode
1750 1750  )))
1751 1751  
1752 1752  (((
1753 -(% style="background-color:#dcdcdc" %) AT+ADR=0(%%) Set the Adaptive Data Rate Off
1793 +(% style="background-color:#dcdcdc" %) AT+ADR=0(%%)  Set the Adaptive Data Rate Off
1754 1754  )))
1755 1755  
1756 1756  (((
1757 -(% style="background-color:#dcdcdc" %) AT+DR=5(%%)  Set Data Rate
1797 +(% style="background-color:#dcdcdc" %) AT+DR=5(%%)  Set Data Rate
1758 1758  )))
1759 1759  
1760 1760  (((
1761 -(% style="background-color:#dcdcdc" %) AT+TDC=60000(%%)  Set transmit interval to 60 seconds
1801 +(% style="background-color:#dcdcdc" %) AT+TDC=60000(%%)  Set transmit interval to 60 seconds
1762 1762  )))
1763 1763  
1764 1764  (((
1765 -(% style="background-color:#dcdcdc" %) AT+CHS=868400000(%%) Set transmit frequency to 868.4Mhz
1805 +(% style="background-color:#dcdcdc" %) AT+CHS=868400000(%%)  Set transmit frequency to 868.4Mhz
1766 1766  )))
1767 1767  
1768 1768  (((
1769 -(% style="background-color:#dcdcdc" %) AT+RX2FQ=868400000(%%) Set RX2Frequency to 868.4Mhz (according to the result from server)
1809 +(% style="background-color:#dcdcdc" %) AT+RX2FQ=868400000(%%)  Set RX2Frequency to 868.4Mhz (according to the result from server)
1770 1770  )))
1771 1771  
1772 1772  (((
1773 -(% style="background-color:#dcdcdc" %) AT+RX2DR=5(%%)  Set RX2DR to match the downlink DR from server. see below
1813 +(% style="background-color:#dcdcdc" %) AT+RX2DR=5(%%)  Set RX2DR to match the downlink DR from server. see below
1774 1774  )))
1775 1775  
1776 1776  (((
1777 -(% style="background-color:#dcdcdc" %) AT+DADDR=26 01 1A F1 (%%)Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1817 +(% style="background-color:#dcdcdc" %) AT+DADDR=26 01 1A F1 (%%) Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1778 1778  )))
1779 1779  
1780 1780  (((
1781 -(% style="background-color:#dcdcdc" %) ATZ         (%%) Reset MCU
1821 +(% style="background-color:#dcdcdc" %) ATZ         (%%) Reset MCU
1822 +
1823 +
1782 1782  )))
1783 1783  
1784 1784  (((
... ... @@ -1801,7 +1801,6 @@
1801 1801  )))
1802 1802  
1803 1803  
1804 -
1805 1805  === 4.2.3 Change to Class A ===
1806 1806  
1807 1807  If sensor JOINED
... ... @@ -1984,7 +1984,6 @@
1984 1984  * (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865
1985 1985  * (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779
1986 1986  
1987 -
1988 1988  = 8. Packing Info =
1989 1989  
1990 1990  
... ... @@ -2002,7 +2002,6 @@
2002 2002  * Package Size / pcs : 14.5 x 8 x 5 cm
2003 2003  * Weight / pcs : 170g
2004 2004  
2005 -
2006 2006  = 9. Support =
2007 2007  
2008 2008  * (((
... ... @@ -2012,7 +2012,6 @@
2012 2012  Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
2013 2013  )))
2014 2014  
2015 -
2016 2016  = 10. Reference​​​​​ =
2017 2017  
2018 2018  * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved