From version < 77.44 >
edited by Xiaoling
on 2022/06/10 09:01
To version < 77.60 >
edited by Xiaoling
on 2022/06/10 09:13
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -162,7 +162,6 @@
162 162  
163 163  )))
164 164  
165 -
166 166  == 1.3 Features ==
167 167  
168 168  * LoRaWAN Class A & Class C protocol
... ... @@ -173,7 +173,6 @@
173 173  * Firmware upgradable via program port
174 174  * Counting
175 175  
176 -
177 177  == 1.4  Applications ==
178 178  
179 179  * Smart Buildings & Home Automation
... ... @@ -183,7 +183,6 @@
183 183  * Smart Cities
184 184  * Smart Factory
185 185  
186 -
187 187  == 1.5 Hardware Variants ==
188 188  
189 189  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -197,7 +197,6 @@
197 197  * 1 x Counting Port
198 198  )))
199 199  
200 -
201 201  = 2. Power ON Device =
202 202  
203 203  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -279,7 +279,6 @@
279 279  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
280 280  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
281 281  
282 -
283 283  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
284 284  
285 285  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -330,7 +330,6 @@
330 330  ** DO1 is high in case there is load between DO1 and V+.
331 331  ** DO1 LED is off in both case
332 332  
333 -
334 334  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
335 335  
336 336  **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins.
... ... @@ -745,7 +745,6 @@
745 745  
746 746  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
747 747  
748 -
749 749  === 3.4.1 Common Commands ===
750 750  
751 751  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -1267,11 +1267,11 @@
1267 1267  Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps:
1268 1268  
1269 1269  (((
1270 -**Step 1**: Be sure that your device is programmed and properly connected to the network at this time.
1263 +(% style="color:blue" %)**Step 1**(%%): Be sure that your device is programmed and properly connected to the network at this time.
1271 1271  )))
1272 1272  
1273 1273  (((
1274 -**Step 2**: To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps:
1267 +(% style="color:blue" %)**Step 2**(%%): To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps:
1275 1275  )))
1276 1276  
1277 1277  [[image:1653356737703-362.png||height="232" width="732"]]
... ... @@ -1278,12 +1278,13 @@
1278 1278  
1279 1279  [[image:image-20220524094641-11.png||height="390" width="723"]]
1280 1280  
1274 +
1281 1281  [[image:image-20220524094641-12.png||height="402" width="718"]]
1282 1282  
1283 1283  
1284 -**Step 3**: Create an account or log in Mydevices.
1278 +(% style="color:blue" %)**Step 3**(%%): Create an account or log in Mydevices.
1285 1285  
1286 -**Step 4**: Search LT-22222-L(for both LT-22222-L / LT-33222-L) and add DevEUI.(% style="display:none" %)
1280 +(% style="color:blue" %)**Step 4**(%%): Search LT-22222-L(for both LT-22222-L / LT-33222-L) and add DevEUI.(% style="display:none" %)
1287 1287  
1288 1288  Search under The things network
1289 1289  
... ... @@ -1290,16 +1290,21 @@
1290 1290  [[image:1653356838789-523.png||height="337" width="740"]]
1291 1291  
1292 1292  
1287 +
1293 1293  After added, the sensor data arrive TTN, it will also arrive and show in Mydevices.
1294 1294  
1295 1295  [[image:image-20220524094909-1.png||height="335" width="729"]]
1296 1296  
1292 +
1297 1297  [[image:image-20220524094909-2.png||height="337" width="729"]]
1298 1298  
1295 +
1299 1299  [[image:image-20220524094909-3.png||height="338" width="727"]]
1300 1300  
1298 +
1301 1301  [[image:image-20220524094909-4.png||height="339" width="728"]](% style="display:none" %)
1302 1302  
1301 +
1303 1303  [[image:image-20220524094909-5.png||height="341" width="734"]]
1304 1304  
1305 1305  
... ... @@ -1339,7 +1339,7 @@
1339 1339  )))
1340 1340  
1341 1341  (((
1342 -**Example1**: Connect to a Low active sensor.
1341 +(% style="color:blue" %)**Example1**(%%): Connect to a Low active sensor.
1343 1343  )))
1344 1344  
1345 1345  (((
... ... @@ -1370,7 +1370,7 @@
1370 1370  )))
1371 1371  
1372 1372  (((
1373 -**Example2**: Connect to a High active sensor.
1372 +(% style="color:blue" %)**Example2**(%%): Connect to a High active sensor.
1374 1374  )))
1375 1375  
1376 1376  (((
... ... @@ -1401,7 +1401,7 @@
1401 1401  )))
1402 1402  
1403 1403  (((
1404 -**Example3**: Connect to a 220v high active sensor.
1403 +(% style="color:blue" %)**Example3**(%%): Connect to a 220v high active sensor.
1405 1405  )))
1406 1406  
1407 1407  (((
... ... @@ -1441,8 +1441,9 @@
1441 1441  
1442 1442  The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is:
1443 1443  
1444 -**AC2 = (IN2 voltage )/12**
1445 1445  
1444 +(% style="color:blue" %)**AC2 = (IN2 voltage )/12**
1445 +
1446 1446  [[image:1653357592296-182.png]]
1447 1447  
1448 1448  Example to connect a 4~~20mA sensor
... ... @@ -1449,17 +1449,18 @@
1449 1449  
1450 1450  We take the wind speed sensor as an example for reference only.
1451 1451  
1452 -Specifications of the wind speed sensor:
1453 1453  
1454 -Red:12~~24v
1453 +**Specifications of the wind speed sensor:**
1455 1455  
1456 -Yellow:4~~20mA
1455 +Red:  12~~24v
1457 1457  
1458 -Black:GND
1457 +Yellow:  4~~20mA
1459 1459  
1459 +Black:  GND
1460 1460  
1461 -Connection diagram:
1462 1462  
1462 +**Connection diagram:**
1463 +
1463 1463  [[image:1653357640609-758.png]]
1464 1464  
1465 1465  [[image:1653357648330-671.png||height="155" width="733"]]
... ... @@ -1491,6 +1491,7 @@
1491 1491  
1492 1492  [[image:1653358238933-385.png]]
1493 1493  
1495 +
1494 1494  (((
1495 1495  In PC, User needs to set (% style="color:#4f81bd" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console for LT. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**)(%%) to active it. As shown below:
1496 1496  )))
... ... @@ -1497,6 +1497,7 @@
1497 1497  
1498 1498  [[image:1653358355238-883.png]]
1499 1499  
1502 +
1500 1500  (((
1501 1501  More detail AT Command manual can be found at [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
1502 1502  )))
... ... @@ -1694,7 +1694,9 @@
1694 1694  === 4.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
1695 1695  
1696 1696  (((
1697 -If device has not joined network yet:
1700 +
1701 +
1702 +**If device has not joined network yet:**
1698 1698  )))
1699 1699  
1700 1700  (((
... ... @@ -1719,7 +1719,7 @@
1719 1719  
1720 1720  
1721 1721  (((
1722 -If device already joined network:
1727 +**If device already joined network:**
1723 1723  )))
1724 1724  
1725 1725  (((
... ... @@ -1737,7 +1737,9 @@
1737 1737  === 4.2.2 Single-channel ABP mode (Use with LG01/LG02) ===
1738 1738  
1739 1739  (((
1740 -(% style="background-color:#dcdcdc" %) 123456(%%)   Enter Password to have AT access.
1745 +
1746 +
1747 +(% style="background-color:#dcdcdc" %)123456(%%)  Enter Password to have AT access.
1741 1741  )))
1742 1742  
1743 1743  (((
... ... @@ -1745,7 +1745,7 @@
1745 1745  )))
1746 1746  
1747 1747  (((
1748 -(% style="background-color:#dcdcdc" %) 123456(%%)   Enter Password to have AT access.
1755 +(% style="background-color:#dcdcdc" %) 123456(%%)  Enter Password to have AT access.
1749 1749  )))
1750 1750  
1751 1751  (((
... ... @@ -1753,39 +1753,41 @@
1753 1753  )))
1754 1754  
1755 1755  (((
1756 -(% style="background-color:#dcdcdc" %) AT+NJM=0(%%) Set to ABP mode
1763 +(% style="background-color:#dcdcdc" %) AT+NJM=0(%%)  Set to ABP mode
1757 1757  )))
1758 1758  
1759 1759  (((
1760 -(% style="background-color:#dcdcdc" %) AT+ADR=0(%%) Set the Adaptive Data Rate Off
1767 +(% style="background-color:#dcdcdc" %) AT+ADR=0(%%)  Set the Adaptive Data Rate Off
1761 1761  )))
1762 1762  
1763 1763  (((
1764 -(% style="background-color:#dcdcdc" %) AT+DR=5(%%)  Set Data Rate
1771 +(% style="background-color:#dcdcdc" %) AT+DR=5(%%)  Set Data Rate
1765 1765  )))
1766 1766  
1767 1767  (((
1768 -(% style="background-color:#dcdcdc" %) AT+TDC=60000(%%)  Set transmit interval to 60 seconds
1775 +(% style="background-color:#dcdcdc" %) AT+TDC=60000(%%)  Set transmit interval to 60 seconds
1769 1769  )))
1770 1770  
1771 1771  (((
1772 -(% style="background-color:#dcdcdc" %) AT+CHS=868400000(%%) Set transmit frequency to 868.4Mhz
1779 +(% style="background-color:#dcdcdc" %) AT+CHS=868400000(%%)  Set transmit frequency to 868.4Mhz
1773 1773  )))
1774 1774  
1775 1775  (((
1776 -(% style="background-color:#dcdcdc" %) AT+RX2FQ=868400000(%%) Set RX2Frequency to 868.4Mhz (according to the result from server)
1783 +(% style="background-color:#dcdcdc" %) AT+RX2FQ=868400000(%%)  Set RX2Frequency to 868.4Mhz (according to the result from server)
1777 1777  )))
1778 1778  
1779 1779  (((
1780 -(% style="background-color:#dcdcdc" %) AT+RX2DR=5(%%)  Set RX2DR to match the downlink DR from server. see below
1787 +(% style="background-color:#dcdcdc" %) AT+RX2DR=5(%%)  Set RX2DR to match the downlink DR from server. see below
1781 1781  )))
1782 1782  
1783 1783  (((
1784 -(% style="background-color:#dcdcdc" %) AT+DADDR=26 01 1A F1 (%%)Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1791 +(% style="background-color:#dcdcdc" %) AT+DADDR=26 01 1A F1 (%%) Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1785 1785  )))
1786 1786  
1787 1787  (((
1788 -(% style="background-color:#dcdcdc" %) ATZ         (%%) Reset MCU
1795 +(% style="background-color:#dcdcdc" %) ATZ         (%%) Reset MCU
1796 +
1797 +
1789 1789  )))
1790 1790  
1791 1791  (((
... ... @@ -1808,7 +1808,6 @@
1808 1808  )))
1809 1809  
1810 1810  
1811 -
1812 1812  === 4.2.3 Change to Class A ===
1813 1813  
1814 1814  If sensor JOINED
... ... @@ -1820,6 +1820,7 @@
1820 1820  
1821 1821  == 5.1 How to upgrade the image? ==
1822 1822  
1831 +
1823 1823  The LT LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to LT to:
1824 1824  
1825 1825  * Support new features
... ... @@ -1826,7 +1826,6 @@
1826 1826  * For bug fix
1827 1827  * Change LoRaWAN bands.
1828 1828  
1829 -
1830 1830  Below shows the hardware connection for how to upload an image to the LT:
1831 1831  
1832 1832  [[image:1653359603330-121.png]]
... ... @@ -1833,12 +1833,12 @@
1833 1833  
1834 1834  
1835 1835  (((
1836 -**Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1837 -**Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].
1838 -**Step3: **Open flashloader; choose the correct COM port to update.
1844 +(% style="color:blue" %)**Step1**(%%)**:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1845 +(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].
1846 +(% style="color:blue" %)**Step3**(%%)**:** Open flashloader; choose the correct COM port to update.
1839 1839  
1840 1840  
1841 -**For LT-22222-L**:
1849 +(% style="color:blue" %)**For LT-22222-L**(%%):
1842 1842  Hold down the PRO button and then momentarily press the RST reset button and the **DO1 led** will change from OFF to ON. When **DO1 LED** is on, it means the device is in download mode.
1843 1843  )))
1844 1844  
... ... @@ -1848,6 +1848,7 @@
1848 1848  
1849 1849  [[image:image-20220524104033-15.png]]
1850 1850  
1859 +
1851 1851  (% style="color:red" %)**Notice**(%%): In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:
1852 1852  
1853 1853  [[image:1653360054704-518.png||height="186" width="745"]]
... ... @@ -1912,7 +1912,7 @@
1912 1912  (% style="background-color:#dcdcdc" %)AT+TDC=60000 (%%) Set transmit interval to 60 seconds
1913 1913  (% style="background-color:#dcdcdc" %)AT+CHS=868400000(%%)  Set transmit frequency to 868.4Mhz
1914 1914  (% style="background-color:#dcdcdc" %)AT+DADDR=26 01 1A F1(%%)  Set Device Address to 26 01 1A F1
1915 -(% style="background-color:#dcdcdc" %)ATZ  (%%) Reset MCU
1924 +(% style="background-color:#dcdcdc" %)ATZ        (%%) Reset MCU
1916 1916  )))
1917 1917  
1918 1918  
... ... @@ -1990,8 +1990,6 @@
1990 1990  * (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865
1991 1991  * (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779
1992 1992  
1993 -
1994 -
1995 1995  = 8. Packing Info =
1996 1996  
1997 1997  
... ... @@ -2002,7 +2002,6 @@
2002 2002  * Bracket for controller x1
2003 2003  * Program cable x 1
2004 2004  
2005 -
2006 2006  **Dimension and weight**:
2007 2007  
2008 2008  * Device Size: 13.5 x 7 x 3 cm
... ... @@ -2010,8 +2010,6 @@
2010 2010  * Package Size / pcs : 14.5 x 8 x 5 cm
2011 2011  * Weight / pcs : 170g
2012 2012  
2013 -
2014 -
2015 2015  = 9. Support =
2016 2016  
2017 2017  * (((
... ... @@ -2021,8 +2021,6 @@
2021 2021  Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
2022 2022  )))
2023 2023  
2024 -
2025 -
2026 2026  = 10. Reference​​​​​ =
2027 2027  
2028 2028  * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved