Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1825,19 +1825,13 @@ 1825 1825 * Support new features 1826 1826 * For bug fix 1827 1827 * Change LoRaWAN bands. 1828 - 1829 - 1830 1830 Below shows the hardware connection for how to upload an image to the LT: 1829 +* [[image:1653359603330-121.png]] 1831 1831 1832 -[[image:1653359603330-121.png]] 1833 - 1834 - 1835 1835 ((( 1836 1836 **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1837 1837 **Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 1838 1838 **Step3: **Open flashloader; choose the correct COM port to update. 1839 - 1840 - 1841 1841 **For LT-22222-L**: 1842 1842 Hold down the PRO button and then momentarily press the RST reset button and the **DO1 led** will change from OFF to ON. When **DO1 LED** is on, it means the device is in download mode. 1843 1843 ))) ... ... @@ -1863,11 +1863,14 @@ 1863 1863 1864 1864 ((( 1865 1865 User can follow the introduction for [[how to upgrade image>>||anchor="H5.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download. 1860 + 1861 + 1866 1866 ))) 1867 1867 1868 1868 ((( 1869 1869 1870 1870 1867 + 1871 1871 == 5.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? == 1872 1872 ))) 1873 1873 ... ... @@ -1880,8 +1880,6 @@ 1880 1880 ((( 1881 1881 ((( 1882 1882 Assume we have a LG02 working in the frequency 868400000 now , below is the step. 1883 - 1884 - 1885 1885 ))) 1886 1886 ))) 1887 1887 ... ... @@ -1897,25 +1897,23 @@ 1897 1897 (% style="color:red" %)Note: user just need to make sure above three keys match, User can change either in TTN or Device to make then match. In TTN, NETSKEY and APPSKEY can be configured by user in setting page, but Device Addr is generated by TTN. 1898 1898 ))) 1899 1899 1900 - 1901 1901 ((( 1902 1902 (% style="color:#4f81bd" %)**Step2**(%%)**: **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands: 1903 1903 ))) 1904 1904 1905 1905 ((( 1906 -(% style="background-color:#dcdcdc" %)123456 (%%) 1907 -(% style="background-color:#dcdcdc" %)AT+FDR(%%) 1908 -(% style="background-color:#dcdcdc" %)123456 (%%) 1909 -(% style="background-color:#dcdcdc" %)AT+NJM=0 (%%) 1910 -(% style="background-color:#dcdcdc" %)AT+ADR=0 (%%) 1911 -(% style="background-color:#dcdcdc" %)AT+DR=5 (%%) 1912 -(% style="background-color:#dcdcdc" %)AT+TDC=60000 (%%) 1913 -(% style="background-color:#dcdcdc" %)AT+CHS=868400000(%%) 1914 -(% style="background-color:#dcdcdc" %)AT+DADDR=26 01 1A F1(%%) 1915 -(% style="background-color:#dcdcdc" %)ATZ 1900 +(% style="background-color:#dcdcdc" %)123456 (%%) Enter Password to have AT access. 1901 +(% style="background-color:#dcdcdc" %)AT+FDR (%%) Reset Parameters to Factory Default, Keys Reserve 1902 +(% style="background-color:#dcdcdc" %)123456 (%%) Enter Password to have AT access. 1903 +(% style="background-color:#dcdcdc" %)AT+NJM=0 (%%)Set to ABP mode 1904 +(% style="background-color:#dcdcdc" %)AT+ADR=0 (%%)Set the Adaptive Data Rate Off 1905 +(% style="background-color:#dcdcdc" %)AT+DR=5 (%%) Set Data Rate (Set AT+DR=3 for 915 band) 1906 +(% style="background-color:#dcdcdc" %)AT+TDC=60000 (%%)Set transmit interval to 60 seconds 1907 +(% style="background-color:#dcdcdc" %)AT+CHS=868400000 (%%)Set transmit frequency to 868.4Mhz 1908 +(% style="background-color:#dcdcdc" %)AT+DADDR=26 01 1A F1(%%) Set Device Address to 26 01 1A F1 1909 +(% style="background-color:#dcdcdc" %)ATZ (%%)Reset MCU 1916 1916 ))) 1917 1917 1918 - 1919 1919 ((( 1920 1920 As shown in below: 1921 1921 ))) ... ... @@ -1932,6 +1932,8 @@ 1932 1932 == 5.5 Can i use point to point communication for LT-22222-L? == 1933 1933 1934 1934 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1928 + 1929 + 1935 1935 ))) 1936 1936 1937 1937 ((( ... ... @@ -1948,6 +1948,8 @@ 1948 1948 1949 1949 ((( 1950 1950 Please see this link for how to debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H5.1Howitwork"]] 1946 + 1947 + 1951 1951 ))) 1952 1952 1953 1953 ((( ... ... @@ -1962,7 +1962,11 @@ 1962 1962 1963 1963 ((( 1964 1964 1962 +))) 1965 1965 1964 +((( 1965 + 1966 + 1966 1966 == 6.3 Why I can’t join TTN in US915 /AU915 bands? == 1967 1967 ))) 1968 1968 ... ... @@ -2011,7 +2011,6 @@ 2011 2011 * Weight / pcs : 170g 2012 2012 2013 2013 2014 - 2015 2015 = 9. Support = 2016 2016 2017 2017 * ((( ... ... @@ -2025,7 +2025,10 @@ 2025 2025 2026 2026 = 10. Reference = 2027 2027 2028 -* LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 2028 +* Product Page: 2029 + 2030 +LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 2031 + 2029 2029 * [[Image Download>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]] 2030 2030 * [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 2031 2031 * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]]