Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -824,7 +824,6 @@ 824 824 **Example**: 0x08FF, ask device to send an Uplink 825 825 826 826 827 - 828 828 ==== 3.4.2.4 Enable Trigger Mode ==== 829 829 830 830 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -848,7 +848,6 @@ 848 848 ))) 849 849 850 850 851 - 852 852 ==== 3.4.2.5 Poll trigger settings ==== 853 853 854 854 Poll trigger settings, ... ... @@ -865,7 +865,6 @@ 865 865 ))) 866 866 867 867 868 - 869 869 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 870 870 871 871 Enable Disable DI1/DI2/DI2 as trigger, ... ... @@ -889,7 +889,6 @@ 889 889 ))) 890 890 891 891 892 - 893 893 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 894 894 895 895 Set DI1 or DI3(for LT-33222-L) trigger. ... ... @@ -917,7 +917,6 @@ 917 917 ))) 918 918 919 919 920 - 921 921 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 922 922 923 923 Set DI2 trigger. ... ... @@ -945,7 +945,6 @@ 945 945 ))) 946 946 947 947 948 - 949 949 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 950 950 951 951 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -965,7 +965,6 @@ 965 965 ))) 966 966 967 967 968 - 969 969 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 970 970 971 971 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -985,7 +985,6 @@ 985 985 ))) 986 986 987 987 988 - 989 989 ==== 3.4.2.11 Trigger – Set minimum interval ==== 990 990 991 991 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. ... ... @@ -1005,7 +1005,6 @@ 1005 1005 ))) 1006 1006 1007 1007 1008 - 1009 1009 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 1010 1010 1011 1011 * AT Command: ... ... @@ -1038,7 +1038,6 @@ 1038 1038 ))) 1039 1039 1040 1040 1041 - 1042 1042 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1043 1043 1044 1044 * AT Command: ... ... @@ -1101,7 +1101,6 @@ 1101 1101 DO1 pin no action, DO2 pin set low, DO3 pin set high, last 2 seconds, then DO1 pin no action, DO2 pin set high, DO3 pin set low 1102 1102 1103 1103 1104 - 1105 1105 === 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 === 1106 1106 1107 1107 * AT Command: ... ... @@ -1130,7 +1130,6 @@ 1130 1130 Device will upload a packet if downlink code executes successfully. 1131 1131 1132 1132 1133 - 1134 1134 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1135 1135 1136 1136 * AT Command: ... ... @@ -1181,7 +1181,6 @@ 1181 1181 Relay 1 & relay2 will change to NC, last 2 seconds, then both change to NO. 1182 1182 1183 1183 1184 - 1185 1185 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1186 1186 1187 1187 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] ... ... @@ -1201,7 +1201,6 @@ 1201 1201 ))) 1202 1202 1203 1203 1204 - 1205 1205 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1206 1206 1207 1207 * AT Command: ... ... @@ -1227,7 +1227,6 @@ 1227 1227 ))) 1228 1228 1229 1229 1230 - 1231 1231 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1232 1232 1233 1233 Clear counting for counting mode ... ... @@ -1247,7 +1247,6 @@ 1247 1247 ))) 1248 1248 1249 1249 1250 - 1251 1251 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1252 1252 1253 1253 * AT Command: ... ... @@ -1270,8 +1270,6 @@ 1270 1270 1271 1271 ))) 1272 1272 1273 - 1274 - 1275 1275 == 3.5 Integrate with Mydevice == 1276 1276 1277 1277 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: ... ... @@ -1313,7 +1313,6 @@ 1313 1313 [[image:image-20220524094909-5.png||height="341" width="734"]] 1314 1314 1315 1315 1316 - 1317 1317 == 3.6 Interface Detail == 1318 1318 1319 1319 === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) === ... ... @@ -1323,7 +1323,6 @@ 1323 1323 [[image:1653356991268-289.png]] 1324 1324 1325 1325 1326 - 1327 1327 === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) === 1328 1328 1329 1329 ((( ... ... @@ -1438,7 +1438,6 @@ 1438 1438 ))) 1439 1439 1440 1440 1441 - 1442 1442 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1443 1443 1444 1444 NPN output: GND or Float. Max voltage can apply to output pin is 36v. ... ... @@ -1446,7 +1446,6 @@ 1446 1446 [[image:1653357531600-905.png]] 1447 1447 1448 1448 1449 - 1450 1450 === 3.6.4 Analog Input Interface === 1451 1451 1452 1452 The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is: ... ... @@ -1475,7 +1475,6 @@ 1475 1475 [[image:1653357648330-671.png||height="155" width="733"]] 1476 1476 1477 1477 1478 - 1479 1479 === 3.6.5 Relay Output === 1480 1480 1481 1481 (((