<
From version < 77.31 >
edited by Xiaoling
on 2022/06/10 08:43
To version < 77.19 >
edited by Xiaoling
on 2022/06/10 08:40
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -807,7 +807,6 @@
807 807  )))
808 808  
809 809  
810 -
811 811  ==== 3.4.2.3 Poll an uplink ====
812 812  
813 813  * AT Command:
... ... @@ -824,7 +824,6 @@
824 824  **Example**: 0x08FF, ask device to send an Uplink
825 825  
826 826  
827 -
828 828  ==== 3.4.2.4 Enable Trigger Mode ====
829 829  
830 830  Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
... ... @@ -848,7 +848,6 @@
848 848  )))
849 849  
850 850  
851 -
852 852  ==== 3.4.2.5 Poll trigger settings ====
853 853  
854 854  Poll trigger settings,
... ... @@ -865,7 +865,6 @@
865 865  )))
866 866  
867 867  
868 -
869 869  ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ====
870 870  
871 871  Enable Disable DI1/DI2/DI2 as trigger,
... ... @@ -889,7 +889,6 @@
889 889  )))
890 890  
891 891  
892 -
893 893  ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ====
894 894  
895 895  Set DI1 or DI3(for LT-33222-L) trigger.
... ... @@ -917,7 +917,6 @@
917 917  )))
918 918  
919 919  
920 -
921 921  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
922 922  
923 923  Set DI2 trigger.
... ... @@ -945,7 +945,6 @@
945 945  )))
946 946  
947 947  
948 -
949 949  ==== 3.4.2.9 Trigger – Set AC (current) as trigger ====
950 950  
951 951  Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
... ... @@ -965,7 +965,6 @@
965 965  )))
966 966  
967 967  
968 -
969 969  ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ====
970 970  
971 971  Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
... ... @@ -985,7 +985,6 @@
985 985  )))
986 986  
987 987  
988 -
989 989  ==== 3.4.2.11 Trigger – Set minimum interval ====
990 990  
991 991  Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger.
... ... @@ -1005,7 +1005,6 @@
1005 1005  )))
1006 1006  
1007 1007  
1008 -
1009 1009  ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ====
1010 1010  
1011 1011  * AT Command:
... ... @@ -1038,7 +1038,6 @@
1038 1038  )))
1039 1039  
1040 1040  
1041 -
1042 1042  ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ====
1043 1043  
1044 1044  * AT Command:
... ... @@ -1101,7 +1101,6 @@
1101 1101  DO1 pin no action, DO2 pin set low, DO3 pin set high, last 2 seconds, then DO1 pin no action, DO2 pin set high, DO3 pin set low
1102 1102  
1103 1103  
1104 -
1105 1105  === 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
1106 1106  
1107 1107  * AT Command:
... ... @@ -1130,7 +1130,6 @@
1130 1130  Device will upload a packet if downlink code executes successfully.
1131 1131  
1132 1132  
1133 -
1134 1134  ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ====
1135 1135  
1136 1136  * AT Command:
... ... @@ -1181,7 +1181,6 @@
1181 1181  Relay 1 & relay2 will change to NC, last 2 seconds, then both change to NO.
1182 1182  
1183 1183  
1184 -
1185 1185  ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ====
1186 1186  
1187 1187  When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
... ... @@ -1201,7 +1201,6 @@
1201 1201  )))
1202 1202  
1203 1203  
1204 -
1205 1205  ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ====
1206 1206  
1207 1207  * AT Command:
... ... @@ -1227,7 +1227,6 @@
1227 1227  )))
1228 1228  
1229 1229  
1230 -
1231 1231  ==== 3.4.2.18 Counting ~-~- Clear Counting ====
1232 1232  
1233 1233  Clear counting for counting mode
... ... @@ -1247,7 +1247,6 @@
1247 1247  )))
1248 1248  
1249 1249  
1250 -
1251 1251  ==== 3.4.2.19 Counting ~-~- Change counting mode save time ====
1252 1252  
1253 1253  * AT Command:
... ... @@ -1270,8 +1270,6 @@
1270 1270  
1271 1271  )))
1272 1272  
1273 -
1274 -
1275 1275  == 3.5 Integrate with Mydevice ==
1276 1276  
1277 1277  Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps:
... ... @@ -1313,7 +1313,6 @@
1313 1313  [[image:image-20220524094909-5.png||height="341" width="734"]]
1314 1314  
1315 1315  
1316 -
1317 1317  == 3.6 Interface Detail ==
1318 1318  
1319 1319  === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) ===
... ... @@ -1323,7 +1323,6 @@
1323 1323  [[image:1653356991268-289.png]]
1324 1324  
1325 1325  
1326 -
1327 1327  === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) ===
1328 1328  
1329 1329  (((
... ... @@ -1438,7 +1438,6 @@
1438 1438  )))
1439 1439  
1440 1440  
1441 -
1442 1442  === 3.6.3 Digital Output Port: DO1/DO2 /DO3 ===
1443 1443  
1444 1444  NPN output: GND or Float. Max voltage can apply to output pin is 36v.
... ... @@ -1446,7 +1446,6 @@
1446 1446  [[image:1653357531600-905.png]]
1447 1447  
1448 1448  
1449 -
1450 1450  === 3.6.4 Analog Input Interface ===
1451 1451  
1452 1452  The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is:
... ... @@ -1475,7 +1475,6 @@
1475 1475  [[image:1653357648330-671.png||height="155" width="733"]]
1476 1476  
1477 1477  
1478 -
1479 1479  === 3.6.5 Relay Output ===
1480 1480  
1481 1481  (((
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0