... ... @@ -1101,6 +1101,7 @@
1101 1101  DO1 pin no action, DO2 pin set low, DO3 pin set high, last 2 seconds, then DO1 pin no action, DO2 pin set high, DO3 pin set low
1102 1102  
1103 1103  
1104 +
1104 1104  === 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
1105 1105  
1106 1106  * AT Command:
... ... @@ -1129,6 +1129,7 @@
1129 1129  Device will upload a packet if downlink code executes successfully.
1130 1130  
1131 1131  
1133 +
1132 1132  ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ====
1133 1133  
1134 1134  * AT Command:
... ... @@ -1179,6 +1179,7 @@
1179 1179  Relay 1 & relay2 will change to NC, last 2 seconds, then both change to NO.
1180 1180  
1181 1181  
1184 +
1182 1182  ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ====
1183 1183  
1184 1184  When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
... ... @@ -1198,6 +1198,7 @@
1198 1198  )))
1199 1199  
1200 1200  
1204 +
1201 1201  ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ====
1202 1202  
1203 1203  * AT Command:
... ... @@ -1223,6 +1223,7 @@
1223 1223  )))
1224 1224  
1225 1225  
1230 +
1226 1226  ==== 3.4.2.18 Counting ~-~- Clear Counting ====
1227 1227  
1228 1228  Clear counting for counting mode
... ... @@ -1242,6 +1242,7 @@
1242 1242  )))
1243 1243  
1244 1244  
1250 +
1245 1245  ==== 3.4.2.19 Counting ~-~- Change counting mode save time ====
1246 1246  
1247 1247  * AT Command:
... ... @@ -1264,6 +1264,8 @@
1264 1264  
1265 1265  )))
1266 1266  
1273 +
1274 +
1267 1267  == 3.5 Integrate with Mydevice ==
1268 1268  
1269 1269  Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps:
... ... @@ -1305,6 +1305,7 @@
1305 1305  [[image:image-20220524094909-5.png||height="341" width="734"]]
1306 1306  
1307 1307  
1316 +
1308 1308  == 3.6 Interface Detail ==
1309 1309  
1310 1310  === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) ===
... ... @@ -1314,6 +1314,7 @@
1314 1314  [[image:1653356991268-289.png]]
1315 1315  
1316 1316  
1326 +
1317 1317  === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) ===
1318 1318  
1319 1319  (((
... ... @@ -1428,6 +1428,7 @@
1428 1428  )))
1429 1429  
1430 1430  
1441 +
1431 1431  === 3.6.3 Digital Output Port: DO1/DO2 /DO3 ===
1432 1432  
1433 1433  NPN output: GND or Float. Max voltage can apply to output pin is 36v.
... ... @@ -1435,6 +1435,7 @@
1435 1435  [[image:1653357531600-905.png]]
1436 1436  
1437 1437  
1449 +
1438 1438  === 3.6.4 Analog Input Interface ===
1439 1439  
1440 1440  The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is:
... ... @@ -1463,6 +1463,7 @@
1463 1463  [[image:1653357648330-671.png||height="155" width="733"]]
1464 1464  
1465 1465  
1478 +
1466 1466  === 3.6.5 Relay Output ===
1467 1467  
1468 1468  (((