Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -985,6 +985,7 @@ 985 985 ))) 986 986 987 987 988 + 988 988 ==== 3.4.2.11 Trigger – Set minimum interval ==== 989 989 990 990 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. ... ... @@ -1004,6 +1004,7 @@ 1004 1004 ))) 1005 1005 1006 1006 1008 + 1007 1007 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 1008 1008 1009 1009 * AT Command: ... ... @@ -1036,6 +1036,7 @@ 1036 1036 ))) 1037 1037 1038 1038 1041 + 1039 1039 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1040 1040 1041 1041 * AT Command: ... ... @@ -1098,6 +1098,7 @@ 1098 1098 DO1 pin no action, DO2 pin set low, DO3 pin set high, last 2 seconds, then DO1 pin no action, DO2 pin set high, DO3 pin set low 1099 1099 1100 1100 1104 + 1101 1101 === 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 === 1102 1102 1103 1103 * AT Command: ... ... @@ -1126,6 +1126,7 @@ 1126 1126 Device will upload a packet if downlink code executes successfully. 1127 1127 1128 1128 1133 + 1129 1129 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1130 1130 1131 1131 * AT Command: ... ... @@ -1176,6 +1176,7 @@ 1176 1176 Relay 1 & relay2 will change to NC, last 2 seconds, then both change to NO. 1177 1177 1178 1178 1184 + 1179 1179 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1180 1180 1181 1181 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] ... ... @@ -1195,6 +1195,7 @@ 1195 1195 ))) 1196 1196 1197 1197 1204 + 1198 1198 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1199 1199 1200 1200 * AT Command: ... ... @@ -1220,6 +1220,7 @@ 1220 1220 ))) 1221 1221 1222 1222 1230 + 1223 1223 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1224 1224 1225 1225 Clear counting for counting mode ... ... @@ -1239,6 +1239,7 @@ 1239 1239 ))) 1240 1240 1241 1241 1250 + 1242 1242 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1243 1243 1244 1244 * AT Command: ... ... @@ -1261,6 +1261,8 @@ 1261 1261 1262 1262 ))) 1263 1263 1273 + 1274 + 1264 1264 == 3.5 Integrate with Mydevice == 1265 1265 1266 1266 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: ... ... @@ -1302,6 +1302,7 @@ 1302 1302 [[image:image-20220524094909-5.png||height="341" width="734"]] 1303 1303 1304 1304 1316 + 1305 1305 == 3.6 Interface Detail == 1306 1306 1307 1307 === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) === ... ... @@ -1311,6 +1311,7 @@ 1311 1311 [[image:1653356991268-289.png]] 1312 1312 1313 1313 1326 + 1314 1314 === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) === 1315 1315 1316 1316 ((( ... ... @@ -1425,6 +1425,7 @@ 1425 1425 ))) 1426 1426 1427 1427 1441 + 1428 1428 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1429 1429 1430 1430 NPN output: GND or Float. Max voltage can apply to output pin is 36v. ... ... @@ -1432,6 +1432,7 @@ 1432 1432 [[image:1653357531600-905.png]] 1433 1433 1434 1434 1449 + 1435 1435 === 3.6.4 Analog Input Interface === 1436 1436 1437 1437 The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is: ... ... @@ -1460,6 +1460,7 @@ 1460 1460 [[image:1653357648330-671.png||height="155" width="733"]] 1461 1461 1462 1462 1478 + 1463 1463 === 3.6.5 Relay Output === 1464 1464 1465 1465 (((