Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -889,6 +889,7 @@ 889 889 ))) 890 890 891 891 892 + 892 892 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 893 893 894 894 Set DI1 or DI3(for LT-33222-L) trigger. ... ... @@ -916,6 +916,7 @@ 916 916 ))) 917 917 918 918 920 + 919 919 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 920 920 921 921 Set DI2 trigger. ... ... @@ -943,6 +943,7 @@ 943 943 ))) 944 944 945 945 948 + 946 946 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 947 947 948 948 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -962,6 +962,7 @@ 962 962 ))) 963 963 964 964 968 + 965 965 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 966 966 967 967 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -981,6 +981,7 @@ 981 981 ))) 982 982 983 983 988 + 984 984 ==== 3.4.2.11 Trigger – Set minimum interval ==== 985 985 986 986 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. ... ... @@ -1000,6 +1000,7 @@ 1000 1000 ))) 1001 1001 1002 1002 1008 + 1003 1003 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 1004 1004 1005 1005 * AT Command: ... ... @@ -1032,6 +1032,7 @@ 1032 1032 ))) 1033 1033 1034 1034 1041 + 1035 1035 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1036 1036 1037 1037 * AT Command: ... ... @@ -1094,6 +1094,7 @@ 1094 1094 DO1 pin no action, DO2 pin set low, DO3 pin set high, last 2 seconds, then DO1 pin no action, DO2 pin set high, DO3 pin set low 1095 1095 1096 1096 1104 + 1097 1097 === 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 === 1098 1098 1099 1099 * AT Command: ... ... @@ -1122,6 +1122,7 @@ 1122 1122 Device will upload a packet if downlink code executes successfully. 1123 1123 1124 1124 1133 + 1125 1125 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1126 1126 1127 1127 * AT Command: ... ... @@ -1172,6 +1172,7 @@ 1172 1172 Relay 1 & relay2 will change to NC, last 2 seconds, then both change to NO. 1173 1173 1174 1174 1184 + 1175 1175 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1176 1176 1177 1177 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] ... ... @@ -1191,6 +1191,7 @@ 1191 1191 ))) 1192 1192 1193 1193 1204 + 1194 1194 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1195 1195 1196 1196 * AT Command: ... ... @@ -1216,6 +1216,7 @@ 1216 1216 ))) 1217 1217 1218 1218 1230 + 1219 1219 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1220 1220 1221 1221 Clear counting for counting mode ... ... @@ -1235,6 +1235,7 @@ 1235 1235 ))) 1236 1236 1237 1237 1250 + 1238 1238 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1239 1239 1240 1240 * AT Command: ... ... @@ -1257,6 +1257,8 @@ 1257 1257 1258 1258 ))) 1259 1259 1273 + 1274 + 1260 1260 == 3.5 Integrate with Mydevice == 1261 1261 1262 1262 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: ... ... @@ -1298,6 +1298,7 @@ 1298 1298 [[image:image-20220524094909-5.png||height="341" width="734"]] 1299 1299 1300 1300 1316 + 1301 1301 == 3.6 Interface Detail == 1302 1302 1303 1303 === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) === ... ... @@ -1307,6 +1307,7 @@ 1307 1307 [[image:1653356991268-289.png]] 1308 1308 1309 1309 1326 + 1310 1310 === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) === 1311 1311 1312 1312 ((( ... ... @@ -1421,6 +1421,7 @@ 1421 1421 ))) 1422 1422 1423 1423 1441 + 1424 1424 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1425 1425 1426 1426 NPN output: GND or Float. Max voltage can apply to output pin is 36v. ... ... @@ -1428,6 +1428,7 @@ 1428 1428 [[image:1653357531600-905.png]] 1429 1429 1430 1430 1449 + 1431 1431 === 3.6.4 Analog Input Interface === 1432 1432 1433 1433 The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is: ... ... @@ -1456,6 +1456,7 @@ 1456 1456 [[image:1653357648330-671.png||height="155" width="733"]] 1457 1457 1458 1458 1478 + 1459 1459 === 3.6.5 Relay Output === 1460 1460 1461 1461 (((