<
From version < 77.22 >
edited by Xiaoling
on 2022/06/10 08:41
To version < 77.31 >
edited by Xiaoling
on 2022/06/10 08:43
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -865,6 +865,7 @@
865 865  )))
866 866  
867 867  
868 +
868 868  ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ====
869 869  
870 870  Enable Disable DI1/DI2/DI2 as trigger,
... ... @@ -888,6 +888,7 @@
888 888  )))
889 889  
890 890  
892 +
891 891  ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ====
892 892  
893 893  Set DI1 or DI3(for LT-33222-L) trigger.
... ... @@ -915,6 +915,7 @@
915 915  )))
916 916  
917 917  
920 +
918 918  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
919 919  
920 920  Set DI2 trigger.
... ... @@ -942,6 +942,7 @@
942 942  )))
943 943  
944 944  
948 +
945 945  ==== 3.4.2.9 Trigger – Set AC (current) as trigger ====
946 946  
947 947  Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
... ... @@ -961,6 +961,7 @@
961 961  )))
962 962  
963 963  
968 +
964 964  ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ====
965 965  
966 966  Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
... ... @@ -980,6 +980,7 @@
980 980  )))
981 981  
982 982  
988 +
983 983  ==== 3.4.2.11 Trigger – Set minimum interval ====
984 984  
985 985  Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger.
... ... @@ -999,6 +999,7 @@
999 999  )))
1000 1000  
1001 1001  
1008 +
1002 1002  ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ====
1003 1003  
1004 1004  * AT Command:
... ... @@ -1031,6 +1031,7 @@
1031 1031  )))
1032 1032  
1033 1033  
1041 +
1034 1034  ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ====
1035 1035  
1036 1036  * AT Command:
... ... @@ -1093,6 +1093,7 @@
1093 1093  DO1 pin no action, DO2 pin set low, DO3 pin set high, last 2 seconds, then DO1 pin no action, DO2 pin set high, DO3 pin set low
1094 1094  
1095 1095  
1104 +
1096 1096  === 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
1097 1097  
1098 1098  * AT Command:
... ... @@ -1121,6 +1121,7 @@
1121 1121  Device will upload a packet if downlink code executes successfully.
1122 1122  
1123 1123  
1133 +
1124 1124  ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ====
1125 1125  
1126 1126  * AT Command:
... ... @@ -1171,6 +1171,7 @@
1171 1171  Relay 1 & relay2 will change to NC, last 2 seconds, then both change to NO.
1172 1172  
1173 1173  
1184 +
1174 1174  ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ====
1175 1175  
1176 1176  When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
... ... @@ -1190,6 +1190,7 @@
1190 1190  )))
1191 1191  
1192 1192  
1204 +
1193 1193  ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ====
1194 1194  
1195 1195  * AT Command:
... ... @@ -1215,6 +1215,7 @@
1215 1215  )))
1216 1216  
1217 1217  
1230 +
1218 1218  ==== 3.4.2.18 Counting ~-~- Clear Counting ====
1219 1219  
1220 1220  Clear counting for counting mode
... ... @@ -1234,6 +1234,7 @@
1234 1234  )))
1235 1235  
1236 1236  
1250 +
1237 1237  ==== 3.4.2.19 Counting ~-~- Change counting mode save time ====
1238 1238  
1239 1239  * AT Command:
... ... @@ -1256,6 +1256,8 @@
1256 1256  
1257 1257  )))
1258 1258  
1273 +
1274 +
1259 1259  == 3.5 Integrate with Mydevice ==
1260 1260  
1261 1261  Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps:
... ... @@ -1297,6 +1297,7 @@
1297 1297  [[image:image-20220524094909-5.png||height="341" width="734"]]
1298 1298  
1299 1299  
1316 +
1300 1300  == 3.6 Interface Detail ==
1301 1301  
1302 1302  === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) ===
... ... @@ -1306,6 +1306,7 @@
1306 1306  [[image:1653356991268-289.png]]
1307 1307  
1308 1308  
1326 +
1309 1309  === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) ===
1310 1310  
1311 1311  (((
... ... @@ -1420,6 +1420,7 @@
1420 1420  )))
1421 1421  
1422 1422  
1441 +
1423 1423  === 3.6.3 Digital Output Port: DO1/DO2 /DO3 ===
1424 1424  
1425 1425  NPN output: GND or Float. Max voltage can apply to output pin is 36v.
... ... @@ -1427,6 +1427,7 @@
1427 1427  [[image:1653357531600-905.png]]
1428 1428  
1429 1429  
1449 +
1430 1430  === 3.6.4 Analog Input Interface ===
1431 1431  
1432 1432  The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is:
... ... @@ -1455,6 +1455,7 @@
1455 1455  [[image:1653357648330-671.png||height="155" width="733"]]
1456 1456  
1457 1457  
1478 +
1458 1458  === 3.6.5 Relay Output ===
1459 1459  
1460 1460  (((
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0