Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -848,6 +848,7 @@ 848 848 ))) 849 849 850 850 851 + 851 851 ==== 3.4.2.5 Poll trigger settings ==== 852 852 853 853 Poll trigger settings, ... ... @@ -864,6 +864,7 @@ 864 864 ))) 865 865 866 866 868 + 867 867 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 868 868 869 869 Enable Disable DI1/DI2/DI2 as trigger, ... ... @@ -887,6 +887,7 @@ 887 887 ))) 888 888 889 889 892 + 890 890 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 891 891 892 892 Set DI1 or DI3(for LT-33222-L) trigger. ... ... @@ -914,6 +914,7 @@ 914 914 ))) 915 915 916 916 920 + 917 917 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 918 918 919 919 Set DI2 trigger. ... ... @@ -941,6 +941,7 @@ 941 941 ))) 942 942 943 943 948 + 944 944 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 945 945 946 946 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -960,6 +960,7 @@ 960 960 ))) 961 961 962 962 968 + 963 963 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 964 964 965 965 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -979,6 +979,7 @@ 979 979 ))) 980 980 981 981 988 + 982 982 ==== 3.4.2.11 Trigger – Set minimum interval ==== 983 983 984 984 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. ... ... @@ -998,6 +998,7 @@ 998 998 ))) 999 999 1000 1000 1008 + 1001 1001 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 1002 1002 1003 1003 * AT Command: ... ... @@ -1030,6 +1030,7 @@ 1030 1030 ))) 1031 1031 1032 1032 1041 + 1033 1033 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1034 1034 1035 1035 * AT Command: ... ... @@ -1092,6 +1092,7 @@ 1092 1092 DO1 pin no action, DO2 pin set low, DO3 pin set high, last 2 seconds, then DO1 pin no action, DO2 pin set high, DO3 pin set low 1093 1093 1094 1094 1104 + 1095 1095 === 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 === 1096 1096 1097 1097 * AT Command: ... ... @@ -1120,6 +1120,7 @@ 1120 1120 Device will upload a packet if downlink code executes successfully. 1121 1121 1122 1122 1133 + 1123 1123 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1124 1124 1125 1125 * AT Command: ... ... @@ -1170,6 +1170,7 @@ 1170 1170 Relay 1 & relay2 will change to NC, last 2 seconds, then both change to NO. 1171 1171 1172 1172 1184 + 1173 1173 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1174 1174 1175 1175 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] ... ... @@ -1189,6 +1189,7 @@ 1189 1189 ))) 1190 1190 1191 1191 1204 + 1192 1192 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1193 1193 1194 1194 * AT Command: ... ... @@ -1214,6 +1214,7 @@ 1214 1214 ))) 1215 1215 1216 1216 1230 + 1217 1217 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1218 1218 1219 1219 Clear counting for counting mode ... ... @@ -1233,6 +1233,7 @@ 1233 1233 ))) 1234 1234 1235 1235 1250 + 1236 1236 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1237 1237 1238 1238 * AT Command: ... ... @@ -1255,6 +1255,8 @@ 1255 1255 1256 1256 ))) 1257 1257 1273 + 1274 + 1258 1258 == 3.5 Integrate with Mydevice == 1259 1259 1260 1260 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: ... ... @@ -1296,6 +1296,7 @@ 1296 1296 [[image:image-20220524094909-5.png||height="341" width="734"]] 1297 1297 1298 1298 1316 + 1299 1299 == 3.6 Interface Detail == 1300 1300 1301 1301 === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) === ... ... @@ -1305,6 +1305,7 @@ 1305 1305 [[image:1653356991268-289.png]] 1306 1306 1307 1307 1326 + 1308 1308 === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) === 1309 1309 1310 1310 ((( ... ... @@ -1419,6 +1419,7 @@ 1419 1419 ))) 1420 1420 1421 1421 1441 + 1422 1422 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1423 1423 1424 1424 NPN output: GND or Float. Max voltage can apply to output pin is 36v. ... ... @@ -1426,6 +1426,7 @@ 1426 1426 [[image:1653357531600-905.png]] 1427 1427 1428 1428 1449 + 1429 1429 === 3.6.4 Analog Input Interface === 1430 1430 1431 1431 The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is: ... ... @@ -1454,6 +1454,7 @@ 1454 1454 [[image:1653357648330-671.png||height="155" width="733"]] 1455 1455 1456 1456 1478 + 1457 1457 === 3.6.5 Relay Output === 1458 1458 1459 1459 (((