From version < 77.2 >
edited by Xiaoling
on 2022/06/10 08:37
To version < 77.30 >
edited by Xiaoling
on 2022/06/10 08:41
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -51,6 +51,8 @@
51 51  == 1.2  Specifications ==
52 52  
53 53  (((
54 +
55 +
54 54  **Hardware System:**
55 55  )))
56 56  
... ... @@ -73,6 +73,7 @@
73 73  )))
74 74  )))
75 75  
78 +
76 76  (((
77 77  **Interface for Model: LT22222-L:**
78 78  )))
... ... @@ -96,6 +96,7 @@
96 96  Power Input 7~~ 24V DC. 
97 97  )))
98 98  
102 +
99 99  (((
100 100  **LoRa Spec:**
101 101  )))
... ... @@ -160,6 +160,8 @@
160 160  
161 161  )))
162 162  
167 +
168 +
163 163  == 1.3 Features ==
164 164  
165 165  * LoRaWAN Class A & Class C protocol
... ... @@ -170,6 +170,8 @@
170 170  * Firmware upgradable via program port
171 171  * Counting
172 172  
179 +
180 +
173 173  == 1.4  Applications ==
174 174  
175 175  * Smart Buildings & Home Automation
... ... @@ -179,6 +179,8 @@
179 179  * Smart Cities
180 180  * Smart Factory
181 181  
190 +
191 +
182 182  == 1.5 Hardware Variants ==
183 183  
184 184  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -192,6 +192,8 @@
192 192  * 1 x Counting Port
193 193  )))
194 194  
205 +
206 +
195 195  = 2. Power ON Device =
196 196  
197 197  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -203,6 +203,7 @@
203 203  [[image:1653297104069-180.png]]
204 204  
205 205  
218 +
206 206  = 3. Operation Mode =
207 207  
208 208  == 3.1 How it works? ==
... ... @@ -217,6 +217,8 @@
217 217  
218 218  )))
219 219  
233 +
234 +
220 220  == 3.2 Example to join LoRaWAN network ==
221 221  
222 222  (((
... ... @@ -258,6 +258,7 @@
258 258  [[image:1653298044601-602.png||height="405" width="709"]]
259 259  
260 260  
276 +
261 261  == 3.3 Uplink Payload ==
262 262  
263 263  There are five working modes + one interrupt mode on LT for different type application:
... ... @@ -269,6 +269,8 @@
269 269  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
270 270  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
271 271  
288 +
289 +
272 272  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
273 273  
274 274  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -304,6 +304,7 @@
304 304  * [1] RO1 relay channel is close and the RO1 LED is ON.
305 305  * [0] RO2 relay channel is open and RO2 LED is OFF;
306 306  
325 +
307 307  **LT22222-L:**
308 308  
309 309  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -319,6 +319,8 @@
319 319  ** DO1 is high in case there is load between DO1 and V+.
320 320  ** DO1 LED is off in both case
321 321  
341 +
342 +
322 322  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
323 323  
324 324  **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins.
... ... @@ -412,6 +412,7 @@
412 412  )))
413 413  
414 414  
436 +
415 415  === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI ===
416 416  
417 417  **LT22222-L**: This mode the DI1 is used as a counting pin.
... ... @@ -456,6 +456,8 @@
456 456  
457 457  )))
458 458  
481 +
482 +
459 459  === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting ===
460 460  
461 461  **LT22222-L**: This mode the DI1 is used as a counting pin.
... ... @@ -537,6 +537,7 @@
537 537  )))
538 538  
539 539  
564 +
540 540  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
541 541  
542 542  **LT22222-L**: This mode the DI1 is used as a counting pin.
... ... @@ -581,6 +581,8 @@
581 581  
582 582  )))
583 583  
609 +
610 +
584 584  === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) ===
585 585  
586 586  (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.**
... ... @@ -704,6 +704,7 @@
704 704  When device got this command, it will send the MOD6 payload.
705 705  
706 706  
734 +
707 707  === 3.3.7 Payload Decoder ===
708 708  
709 709  (((
... ... @@ -712,6 +712,8 @@
712 712  
713 713  )))
714 714  
743 +
744 +
715 715  == 3.4 ​Configure LT via AT or Downlink ==
716 716  
717 717  User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands
... ... @@ -724,11 +724,14 @@
724 724  
725 725  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
726 726  
757 +
758 +
727 727  === 3.4.1 Common Commands ===
728 728  
729 729  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
730 730  
731 731  
764 +
732 732  === 3.4.2 Sensor related commands ===
733 733  
734 734  ==== 3.4.2.1 Set Transmit Interval ====
... ... @@ -752,6 +752,7 @@
752 752  )))
753 753  
754 754  
788 +
755 755  ==== 3.4.2.2 Set Work Mode (AT+MOD) ====
756 756  
757 757  Set work mode.
... ... @@ -773,6 +773,7 @@
773 773  )))
774 774  
775 775  
810 +
776 776  ==== 3.4.2.3 Poll an uplink ====
777 777  
778 778  * AT Command:
... ... @@ -789,6 +789,7 @@
789 789  **Example**: 0x08FF, ask device to send an Uplink
790 790  
791 791  
827 +
792 792  ==== 3.4.2.4 Enable Trigger Mode ====
793 793  
794 794  Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
... ... @@ -812,6 +812,7 @@
812 812  )))
813 813  
814 814  
851 +
815 815  ==== 3.4.2.5 Poll trigger settings ====
816 816  
817 817  Poll trigger settings,
... ... @@ -828,6 +828,7 @@
828 828  )))
829 829  
830 830  
868 +
831 831  ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ====
832 832  
833 833  Enable Disable DI1/DI2/DI2 as trigger,
... ... @@ -851,6 +851,7 @@
851 851  )))
852 852  
853 853  
892 +
854 854  ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ====
855 855  
856 856  Set DI1 or DI3(for LT-33222-L) trigger.
... ... @@ -878,6 +878,7 @@
878 878  )))
879 879  
880 880  
920 +
881 881  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
882 882  
883 883  Set DI2 trigger.
... ... @@ -905,6 +905,7 @@
905 905  )))
906 906  
907 907  
948 +
908 908  ==== 3.4.2.9 Trigger – Set AC (current) as trigger ====
909 909  
910 910  Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
... ... @@ -924,6 +924,7 @@
924 924  )))
925 925  
926 926  
968 +
927 927  ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ====
928 928  
929 929  Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
... ... @@ -943,6 +943,7 @@
943 943  )))
944 944  
945 945  
988 +
946 946  ==== 3.4.2.11 Trigger – Set minimum interval ====
947 947  
948 948  Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger.
... ... @@ -962,6 +962,7 @@
962 962  )))
963 963  
964 964  
1008 +
965 965  ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ====
966 966  
967 967  * AT Command:
... ... @@ -994,6 +994,7 @@
994 994  )))
995 995  
996 996  
1041 +
997 997  ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ====
998 998  
999 999  * AT Command:
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0