<
From version < 77.18 >
edited by Xiaoling
on 2022/06/10 08:40
To version < 75.11 >
edited by Xiaoling
on 2022/06/01 17:29
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -11,9 +11,6 @@
11 11  
12 12  
13 13  
14 -
15 -
16 -
17 17  = 1.Introduction =
18 18  
19 19  == 1.1 What is LT Series I/O Controller ==
... ... @@ -51,8 +51,6 @@
51 51  == 1.2  Specifications ==
52 52  
53 53  (((
54 -
55 -
56 56  **Hardware System:**
57 57  )))
58 58  
... ... @@ -75,7 +75,6 @@
75 75  )))
76 76  )))
77 77  
78 -
79 79  (((
80 80  **Interface for Model: LT22222-L:**
81 81  )))
... ... @@ -99,7 +99,6 @@
99 99  Power Input 7~~ 24V DC. 
100 100  )))
101 101  
102 -
103 103  (((
104 104  **LoRa Spec:**
105 105  )))
... ... @@ -164,8 +164,6 @@
164 164  
165 165  )))
166 166  
167 -
168 -
169 169  == 1.3 Features ==
170 170  
171 171  * LoRaWAN Class A & Class C protocol
... ... @@ -215,7 +215,6 @@
215 215  [[image:1653297104069-180.png]]
216 216  
217 217  
218 -
219 219  = 3. Operation Mode =
220 220  
221 221  == 3.1 How it works? ==
... ... @@ -230,8 +230,6 @@
230 230  
231 231  )))
232 232  
233 -
234 -
235 235  == 3.2 Example to join LoRaWAN network ==
236 236  
237 237  (((
... ... @@ -273,7 +273,6 @@
273 273  [[image:1653298044601-602.png||height="405" width="709"]]
274 274  
275 275  
276 -
277 277  == 3.3 Uplink Payload ==
278 278  
279 279  There are five working modes + one interrupt mode on LT for different type application:
... ... @@ -322,7 +322,6 @@
322 322  * [1] RO1 relay channel is close and the RO1 LED is ON.
323 323  * [0] RO2 relay channel is open and RO2 LED is OFF;
324 324  
325 -
326 326  **LT22222-L:**
327 327  
328 328  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -433,7 +433,6 @@
433 433  )))
434 434  
435 435  
436 -
437 437  === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI ===
438 438  
439 439  **LT22222-L**: This mode the DI1 is used as a counting pin.
... ... @@ -478,8 +478,6 @@
478 478  
479 479  )))
480 480  
481 -
482 -
483 483  === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting ===
484 484  
485 485  **LT22222-L**: This mode the DI1 is used as a counting pin.
... ... @@ -561,7 +561,6 @@
561 561  )))
562 562  
563 563  
564 -
565 565  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
566 566  
567 567  **LT22222-L**: This mode the DI1 is used as a counting pin.
... ... @@ -606,8 +606,6 @@
606 606  
607 607  )))
608 608  
609 -
610 -
611 611  === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) ===
612 612  
613 613  (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.**
... ... @@ -634,7 +634,6 @@
634 634  
635 635  AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
636 636  
637 -
638 638  (% style="color:#4f81bd" %)**Trigger base on current**:
639 639  
640 640  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
... ... @@ -643,7 +643,6 @@
643 643  
644 644  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
645 645  
646 -
647 647  (% style="color:#4f81bd" %)**Trigger base on DI status**:
648 648  
649 649  DI status trigger Flag.
... ... @@ -731,7 +731,6 @@
731 731  When device got this command, it will send the MOD6 payload.
732 732  
733 733  
734 -
735 735  === 3.3.7 Payload Decoder ===
736 736  
737 737  (((
... ... @@ -740,8 +740,6 @@
740 740  
741 741  )))
742 742  
743 -
744 -
745 745  == 3.4 ​Configure LT via AT or Downlink ==
746 746  
747 747  User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands
... ... @@ -750,18 +750,15 @@
750 750  There are two kinds of Commands:
751 751  )))
752 752  
753 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
728 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands
754 754  
755 755  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
756 756  
757 -
758 -
759 759  === 3.4.1 Common Commands ===
760 760  
761 761  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
762 762  
763 763  
764 -
765 765  === 3.4.2 Sensor related commands ===
766 766  
767 767  ==== 3.4.2.1 Set Transmit Interval ====
... ... @@ -824,7 +824,7 @@
824 824  
825 825  ==== 3.4.2.4 Enable Trigger Mode ====
826 826  
827 -Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
799 +Use of trigger mode, please check [[ADDMOD6>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]
828 828  
829 829  * AT Command:
830 830  
... ... @@ -940,7 +940,7 @@
940 940  
941 941  ==== 3.4.2.9 Trigger – Set AC (current) as trigger ====
942 942  
943 -Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
915 +Set current trigger , base on AC port. See [[trigger mode>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]
944 944  
945 945  * AT Command:
946 946  
... ... @@ -953,19 +953,19 @@
953 953  
954 954  (% class="box infomessage" %)
955 955  (((
956 -**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
928 +**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]**
957 957  )))
958 958  
959 959  
960 960  ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ====
961 961  
962 -Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
934 +Set current trigger , base on AV port. See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]
963 963  
964 964  * AT Command:
965 965  
966 966  (% class="box infomessage" %)
967 967  (((
968 -**AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
940 +**AT+AVLIM. See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]**
969 969  )))
970 970  
971 971  * Downlink Payload (prefix 0xAA 00 ):
... ... @@ -972,7 +972,7 @@
972 972  
973 973  (% class="box infomessage" %)
974 974  (((
975 -**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] **
947 +**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] **
976 976  )))
977 977  
978 978  
... ... @@ -1169,13 +1169,13 @@
1169 1169  
1170 1170  ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ====
1171 1171  
1172 -When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1144 +When voltage exceed the threshold, count. Feature see [[MOD4>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]]
1173 1173  
1174 1174  * AT Command:
1175 1175  
1176 1176  (% class="box infomessage" %)
1177 1177  (((
1178 -**AT+VOLMAX    ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]**
1150 +**AT+VOLMAX    ~/~/ See [[MOD4>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]]**
1179 1179  )))
1180 1180  
1181 1181  * Downlink Payload (prefix 0xA5):
... ... @@ -1270,7 +1270,6 @@
1270 1270  
1271 1271  [[image:image-20220524094641-12.png||height="402" width="718"]]
1272 1272  
1273 -
1274 1274  **Step 3**: Create an account or log in Mydevices.
1275 1275  
1276 1276  **Step 4**: Search LT-22222-L(for both LT-22222-L / LT-33222-L) and add DevEUI.(% style="display:none" %)
... ... @@ -1894,11 +1894,6 @@
1894 1894  (((
1895 1895  User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn’t support AT+DEBUG. User can update to latest firmware first.
1896 1896  
1897 -
1898 -== 5.5 Can i use point to point communication for LT-22222-L? ==
1899 -
1900 -Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]]
1901 -
1902 1902  
1903 1903  )))
1904 1904  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0