Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -740,6 +740,8 @@ 740 740 741 741 ))) 742 742 743 + 744 + 743 743 == 3.4 Configure LT via AT or Downlink == 744 744 745 745 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands ... ... @@ -752,11 +752,14 @@ 752 752 753 753 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 754 754 757 + 758 + 755 755 === 3.4.1 Common Commands === 756 756 757 757 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 758 758 759 759 764 + 760 760 === 3.4.2 Sensor related commands === 761 761 762 762 ==== 3.4.2.1 Set Transmit Interval ==== ... ... @@ -780,6 +780,7 @@ 780 780 ))) 781 781 782 782 788 + 783 783 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 784 784 785 785 Set work mode. ... ... @@ -801,6 +801,7 @@ 801 801 ))) 802 802 803 803 810 + 804 804 ==== 3.4.2.3 Poll an uplink ==== 805 805 806 806 * AT Command: ... ... @@ -817,6 +817,7 @@ 817 817 **Example**: 0x08FF, ask device to send an Uplink 818 818 819 819 827 + 820 820 ==== 3.4.2.4 Enable Trigger Mode ==== 821 821 822 822 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -840,6 +840,7 @@ 840 840 ))) 841 841 842 842 851 + 843 843 ==== 3.4.2.5 Poll trigger settings ==== 844 844 845 845 Poll trigger settings, ... ... @@ -856,6 +856,7 @@ 856 856 ))) 857 857 858 858 868 + 859 859 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 860 860 861 861 Enable Disable DI1/DI2/DI2 as trigger, ... ... @@ -879,6 +879,7 @@ 879 879 ))) 880 880 881 881 892 + 882 882 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 883 883 884 884 Set DI1 or DI3(for LT-33222-L) trigger. ... ... @@ -906,6 +906,7 @@ 906 906 ))) 907 907 908 908 920 + 909 909 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 910 910 911 911 Set DI2 trigger. ... ... @@ -933,6 +933,7 @@ 933 933 ))) 934 934 935 935 948 + 936 936 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 937 937 938 938 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -952,6 +952,7 @@ 952 952 ))) 953 953 954 954 968 + 955 955 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 956 956 957 957 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -971,6 +971,7 @@ 971 971 ))) 972 972 973 973 988 + 974 974 ==== 3.4.2.11 Trigger – Set minimum interval ==== 975 975 976 976 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. ... ... @@ -990,6 +990,7 @@ 990 990 ))) 991 991 992 992 1008 + 993 993 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 994 994 995 995 * AT Command: ... ... @@ -1022,6 +1022,7 @@ 1022 1022 ))) 1023 1023 1024 1024 1041 + 1025 1025 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1026 1026 1027 1027 * AT Command: ... ... @@ -1084,6 +1084,7 @@ 1084 1084 DO1 pin no action, DO2 pin set low, DO3 pin set high, last 2 seconds, then DO1 pin no action, DO2 pin set high, DO3 pin set low 1085 1085 1086 1086 1104 + 1087 1087 === 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 === 1088 1088 1089 1089 * AT Command: ... ... @@ -1112,6 +1112,7 @@ 1112 1112 Device will upload a packet if downlink code executes successfully. 1113 1113 1114 1114 1133 + 1115 1115 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1116 1116 1117 1117 * AT Command: ... ... @@ -1162,6 +1162,7 @@ 1162 1162 Relay 1 & relay2 will change to NC, last 2 seconds, then both change to NO. 1163 1163 1164 1164 1184 + 1165 1165 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1166 1166 1167 1167 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] ... ... @@ -1181,6 +1181,7 @@ 1181 1181 ))) 1182 1182 1183 1183 1204 + 1184 1184 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1185 1185 1186 1186 * AT Command: ... ... @@ -1206,6 +1206,7 @@ 1206 1206 ))) 1207 1207 1208 1208 1230 + 1209 1209 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1210 1210 1211 1211 Clear counting for counting mode ... ... @@ -1225,6 +1225,7 @@ 1225 1225 ))) 1226 1226 1227 1227 1250 + 1228 1228 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1229 1229 1230 1230 * AT Command: ... ... @@ -1247,6 +1247,8 @@ 1247 1247 1248 1248 ))) 1249 1249 1273 + 1274 + 1250 1250 == 3.5 Integrate with Mydevice == 1251 1251 1252 1252 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: ... ... @@ -1288,6 +1288,7 @@ 1288 1288 [[image:image-20220524094909-5.png||height="341" width="734"]] 1289 1289 1290 1290 1316 + 1291 1291 == 3.6 Interface Detail == 1292 1292 1293 1293 === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) === ... ... @@ -1297,6 +1297,7 @@ 1297 1297 [[image:1653356991268-289.png]] 1298 1298 1299 1299 1326 + 1300 1300 === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) === 1301 1301 1302 1302 ((( ... ... @@ -1411,6 +1411,7 @@ 1411 1411 ))) 1412 1412 1413 1413 1441 + 1414 1414 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1415 1415 1416 1416 NPN output: GND or Float. Max voltage can apply to output pin is 36v. ... ... @@ -1418,6 +1418,7 @@ 1418 1418 [[image:1653357531600-905.png]] 1419 1419 1420 1420 1449 + 1421 1421 === 3.6.4 Analog Input Interface === 1422 1422 1423 1423 The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is: ... ... @@ -1446,6 +1446,7 @@ 1446 1446 [[image:1653357648330-671.png||height="155" width="733"]] 1447 1447 1448 1448 1478 + 1449 1449 === 3.6.5 Relay Output === 1450 1450 1451 1451 (((