Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -606,6 +606,8 @@ 606 606 607 607 ))) 608 608 609 + 610 + 609 609 === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === 610 610 611 611 (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.** ... ... @@ -729,6 +729,7 @@ 729 729 When device got this command, it will send the MOD6 payload. 730 730 731 731 734 + 732 732 === 3.3.7 Payload Decoder === 733 733 734 734 ((( ... ... @@ -737,6 +737,8 @@ 737 737 738 738 ))) 739 739 743 + 744 + 740 740 == 3.4 Configure LT via AT or Downlink == 741 741 742 742 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands ... ... @@ -749,11 +749,14 @@ 749 749 750 750 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 751 751 757 + 758 + 752 752 === 3.4.1 Common Commands === 753 753 754 754 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 755 755 756 756 764 + 757 757 === 3.4.2 Sensor related commands === 758 758 759 759 ==== 3.4.2.1 Set Transmit Interval ==== ... ... @@ -777,6 +777,7 @@ 777 777 ))) 778 778 779 779 788 + 780 780 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 781 781 782 782 Set work mode. ... ... @@ -798,6 +798,7 @@ 798 798 ))) 799 799 800 800 810 + 801 801 ==== 3.4.2.3 Poll an uplink ==== 802 802 803 803 * AT Command: ... ... @@ -814,6 +814,7 @@ 814 814 **Example**: 0x08FF, ask device to send an Uplink 815 815 816 816 827 + 817 817 ==== 3.4.2.4 Enable Trigger Mode ==== 818 818 819 819 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -837,6 +837,7 @@ 837 837 ))) 838 838 839 839 851 + 840 840 ==== 3.4.2.5 Poll trigger settings ==== 841 841 842 842 Poll trigger settings, ... ... @@ -853,6 +853,7 @@ 853 853 ))) 854 854 855 855 868 + 856 856 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 857 857 858 858 Enable Disable DI1/DI2/DI2 as trigger, ... ... @@ -876,6 +876,7 @@ 876 876 ))) 877 877 878 878 892 + 879 879 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 880 880 881 881 Set DI1 or DI3(for LT-33222-L) trigger. ... ... @@ -903,6 +903,7 @@ 903 903 ))) 904 904 905 905 920 + 906 906 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 907 907 908 908 Set DI2 trigger. ... ... @@ -930,6 +930,7 @@ 930 930 ))) 931 931 932 932 948 + 933 933 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 934 934 935 935 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -949,6 +949,7 @@ 949 949 ))) 950 950 951 951 968 + 952 952 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 953 953 954 954 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -968,6 +968,7 @@ 968 968 ))) 969 969 970 970 988 + 971 971 ==== 3.4.2.11 Trigger – Set minimum interval ==== 972 972 973 973 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. ... ... @@ -987,6 +987,7 @@ 987 987 ))) 988 988 989 989 1008 + 990 990 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 991 991 992 992 * AT Command: