From version < 77.13 >
edited by Xiaoling
on 2022/06/10 08:39
To version < 77.24 >
edited by Xiaoling
on 2022/06/10 08:41
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -478,6 +478,8 @@
478 478  
479 479  )))
480 480  
481 +
482 +
481 481  === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting ===
482 482  
483 483  **LT22222-L**: This mode the DI1 is used as a counting pin.
... ... @@ -559,6 +559,7 @@
559 559  )))
560 560  
561 561  
564 +
562 562  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
563 563  
564 564  **LT22222-L**: This mode the DI1 is used as a counting pin.
... ... @@ -603,6 +603,8 @@
603 603  
604 604  )))
605 605  
609 +
610 +
606 606  === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) ===
607 607  
608 608  (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.**
... ... @@ -726,6 +726,7 @@
726 726  When device got this command, it will send the MOD6 payload.
727 727  
728 728  
734 +
729 729  === 3.3.7 Payload Decoder ===
730 730  
731 731  (((
... ... @@ -734,6 +734,8 @@
734 734  
735 735  )))
736 736  
743 +
744 +
737 737  == 3.4 ​Configure LT via AT or Downlink ==
738 738  
739 739  User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands
... ... @@ -746,11 +746,14 @@
746 746  
747 747  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
748 748  
757 +
758 +
749 749  === 3.4.1 Common Commands ===
750 750  
751 751  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
752 752  
753 753  
764 +
754 754  === 3.4.2 Sensor related commands ===
755 755  
756 756  ==== 3.4.2.1 Set Transmit Interval ====
... ... @@ -774,6 +774,7 @@
774 774  )))
775 775  
776 776  
788 +
777 777  ==== 3.4.2.2 Set Work Mode (AT+MOD) ====
778 778  
779 779  Set work mode.
... ... @@ -795,6 +795,7 @@
795 795  )))
796 796  
797 797  
810 +
798 798  ==== 3.4.2.3 Poll an uplink ====
799 799  
800 800  * AT Command:
... ... @@ -811,6 +811,7 @@
811 811  **Example**: 0x08FF, ask device to send an Uplink
812 812  
813 813  
827 +
814 814  ==== 3.4.2.4 Enable Trigger Mode ====
815 815  
816 816  Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
... ... @@ -834,6 +834,7 @@
834 834  )))
835 835  
836 836  
851 +
837 837  ==== 3.4.2.5 Poll trigger settings ====
838 838  
839 839  Poll trigger settings,
... ... @@ -850,6 +850,7 @@
850 850  )))
851 851  
852 852  
868 +
853 853  ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ====
854 854  
855 855  Enable Disable DI1/DI2/DI2 as trigger,
... ... @@ -873,6 +873,7 @@
873 873  )))
874 874  
875 875  
892 +
876 876  ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ====
877 877  
878 878  Set DI1 or DI3(for LT-33222-L) trigger.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved