Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -51,8 +51,6 @@ 51 51 == 1.2 Specifications == 52 52 53 53 ((( 54 - 55 - 56 56 **Hardware System:** 57 57 ))) 58 58 ... ... @@ -75,7 +75,6 @@ 75 75 ))) 76 76 ))) 77 77 78 - 79 79 ((( 80 80 **Interface for Model: LT22222-L:** 81 81 ))) ... ... @@ -99,7 +99,6 @@ 99 99 Power Input 7~~ 24V DC. 100 100 ))) 101 101 102 - 103 103 ((( 104 104 **LoRa Spec:** 105 105 ))) ... ... @@ -164,8 +164,6 @@ 164 164 165 165 ))) 166 166 167 - 168 - 169 169 == 1.3 Features == 170 170 171 171 * LoRaWAN Class A & Class C protocol ... ... @@ -176,8 +176,6 @@ 176 176 * Firmware upgradable via program port 177 177 * Counting 178 178 179 - 180 - 181 181 == 1.4 Applications == 182 182 183 183 * Smart Buildings & Home Automation ... ... @@ -187,8 +187,6 @@ 187 187 * Smart Cities 188 188 * Smart Factory 189 189 190 - 191 - 192 192 == 1.5 Hardware Variants == 193 193 194 194 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -202,8 +202,6 @@ 202 202 * 1 x Counting Port 203 203 ))) 204 204 205 - 206 - 207 207 = 2. Power ON Device = 208 208 209 209 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -215,7 +215,6 @@ 215 215 [[image:1653297104069-180.png]] 216 216 217 217 218 - 219 219 = 3. Operation Mode = 220 220 221 221 == 3.1 How it works? == ... ... @@ -230,8 +230,6 @@ 230 230 231 231 ))) 232 232 233 - 234 - 235 235 == 3.2 Example to join LoRaWAN network == 236 236 237 237 ((( ... ... @@ -273,7 +273,6 @@ 273 273 [[image:1653298044601-602.png||height="405" width="709"]] 274 274 275 275 276 - 277 277 == 3.3 Uplink Payload == 278 278 279 279 There are five working modes + one interrupt mode on LT for different type application: ... ... @@ -285,8 +285,6 @@ 285 285 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 286 286 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 287 287 288 - 289 - 290 290 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 291 291 292 292 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -322,7 +322,6 @@ 322 322 * [1] RO1 relay channel is close and the RO1 LED is ON. 323 323 * [0] RO2 relay channel is open and RO2 LED is OFF; 324 324 325 - 326 326 **LT22222-L:** 327 327 328 328 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -338,8 +338,6 @@ 338 338 ** DO1 is high in case there is load between DO1 and V+. 339 339 ** DO1 LED is off in both case 340 340 341 - 342 - 343 343 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 344 344 345 345 **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins. ... ... @@ -433,7 +433,6 @@ 433 433 ))) 434 434 435 435 436 - 437 437 === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI === 438 438 439 439 **LT22222-L**: This mode the DI1 is used as a counting pin.