From version < 77.12 >
edited by Xiaoling
on 2022/06/10 08:39
To version < 77.4 >
edited by Xiaoling
on 2022/06/10 08:38
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -187,8 +187,6 @@
187 187  * Smart Cities
188 188  * Smart Factory
189 189  
190 -
191 -
192 192  == 1.5 Hardware Variants ==
193 193  
194 194  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -202,8 +202,6 @@
202 202  * 1 x Counting Port
203 203  )))
204 204  
205 -
206 -
207 207  = 2. Power ON Device =
208 208  
209 209  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -215,7 +215,6 @@
215 215  [[image:1653297104069-180.png]]
216 216  
217 217  
218 -
219 219  = 3. Operation Mode =
220 220  
221 221  == 3.1 How it works? ==
... ... @@ -230,8 +230,6 @@
230 230  
231 231  )))
232 232  
233 -
234 -
235 235  == 3.2 Example to join LoRaWAN network ==
236 236  
237 237  (((
... ... @@ -273,7 +273,6 @@
273 273  [[image:1653298044601-602.png||height="405" width="709"]]
274 274  
275 275  
276 -
277 277  == 3.3 Uplink Payload ==
278 278  
279 279  There are five working modes + one interrupt mode on LT for different type application:
... ... @@ -285,8 +285,6 @@
285 285  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
286 286  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
287 287  
288 -
289 -
290 290  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
291 291  
292 292  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -322,7 +322,6 @@
322 322  * [1] RO1 relay channel is close and the RO1 LED is ON.
323 323  * [0] RO2 relay channel is open and RO2 LED is OFF;
324 324  
325 -
326 326  **LT22222-L:**
327 327  
328 328  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -338,8 +338,6 @@
338 338  ** DO1 is high in case there is load between DO1 and V+.
339 339  ** DO1 LED is off in both case
340 340  
341 -
342 -
343 343  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
344 344  
345 345  **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved