Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -76,8 +76,6 @@ 76 76 ))) 77 77 78 78 ((( 79 - 80 - 81 81 **Interface for Model: LT22222-L:** 82 82 ))) 83 83 ... ... @@ -101,8 +101,6 @@ 101 101 ))) 102 102 103 103 ((( 104 - 105 - 106 106 **LoRa Spec:** 107 107 ))) 108 108 ... ... @@ -168,6 +168,7 @@ 168 168 169 169 170 170 167 + 171 171 == 1.3 Features == 172 172 173 173 * LoRaWAN Class A & Class C protocol ... ... @@ -180,6 +180,7 @@ 180 180 181 181 182 182 180 + 183 183 == 1.4 Applications == 184 184 185 185 * Smart Buildings & Home Automation ... ... @@ -191,6 +191,7 @@ 191 191 192 192 193 193 192 + 194 194 == 1.5 Hardware Variants == 195 195 196 196 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -205,6 +205,7 @@ 205 205 ))) 206 206 207 207 207 + 208 208 = 2. Power ON Device = 209 209 210 210 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -286,6 +286,7 @@ 286 286 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 287 287 288 288 289 + 289 289 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 290 290 291 291 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -324,6 +324,7 @@ 324 324 * [1] RO1 relay channel is close and the RO1 LED is ON. 325 325 * [0] RO2 relay channel is open and RO2 LED is OFF; 326 326 328 + 327 327 **LT22222-L:** 328 328 329 329 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -340,6 +340,7 @@ 340 340 ** DO1 LED is off in both case 341 341 342 342 345 + 343 343 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 344 344 345 345 ... ... @@ -637,6 +637,7 @@ 637 637 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 638 638 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 639 639 643 + 640 640 **AT Command to set Trigger Condition**: 641 641 642 642 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -716,6 +716,7 @@ 716 716 717 717 * Each bits shows if the corresponding trigger has been configured. 718 718 723 + 719 719 **Example:** 720 720 721 721 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -727,6 +727,7 @@ 727 727 728 728 * Each bits shows which status has been trigger on this uplink. 729 729 735 + 730 730 **Example:** 731 731 732 732 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. ... ... @@ -738,6 +738,7 @@ 738 738 739 739 * Each bits shows which status has been trigger on this uplink. 740 740 747 + 741 741 **Example:** 742 742 743 743 00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1. ... ... @@ -779,6 +779,7 @@ 779 779 780 780 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 781 781 789 + 782 782 === 3.4.1 Common Commands === 783 783 784 784 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]