Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -162,8 +162,6 @@ 162 162 163 163 ))) 164 164 165 - 166 - 167 167 == 1.3 Features == 168 168 169 169 * LoRaWAN Class A & Class C protocol ... ... @@ -174,8 +174,6 @@ 174 174 * Firmware upgradable via program port 175 175 * Counting 176 176 177 - 178 - 179 179 == 1.4 Applications == 180 180 181 181 * Smart Buildings & Home Automation ... ... @@ -185,8 +185,6 @@ 185 185 * Smart Cities 186 186 * Smart Factory 187 187 188 - 189 - 190 190 == 1.5 Hardware Variants == 191 191 192 192 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -200,7 +200,6 @@ 200 200 * 1 x Counting Port 201 201 ))) 202 202 203 - 204 204 = 2. Power ON Device = 205 205 206 206 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -223,9 +223,12 @@ 223 223 224 224 ((( 225 225 In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 219 + 220 + 226 226 ))) 227 227 228 228 224 + 229 229 == 3.2 Example to join LoRaWAN network == 230 230 231 231 ((( ... ... @@ -234,13 +234,12 @@ 234 234 235 235 [[image:image-20220523172350-1.png||height="266" width="864"]] 236 236 237 - 238 238 ((( 239 239 The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN: 240 240 ))) 241 241 242 242 ((( 243 - (% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller.238 +**Step 1**: Create a device in TTN with the OTAA keys from LT IO controller. 244 244 ))) 245 245 246 246 ((( ... ... @@ -249,7 +249,6 @@ 249 249 250 250 [[image:1653297924498-393.png]] 251 251 252 - 253 253 Input these keys in the LoRaWAN Server portal. Below is TTN screen shot: 254 254 255 255 Add APP EUI in the application. ... ... @@ -263,7 +263,7 @@ 263 263 264 264 265 265 ((( 266 - (% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.260 +**Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 267 267 ))) 268 268 269 269 [[image:1653298044601-602.png||height="405" width="709"]] ... ... @@ -281,7 +281,6 @@ 281 281 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 282 282 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 283 283 284 - 285 285 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 286 286 287 287 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -289,8 +289,6 @@ 289 289 [[image:image-20220523174024-3.png]] 290 290 291 291 ((( 292 - 293 - 294 294 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 295 295 ))) 296 296 ... ... @@ -304,7 +304,6 @@ 304 304 305 305 For example if payload is: [[image:image-20220523175847-2.png]] 306 306 307 - 308 308 **The value for the interface is: ** 309 309 310 310 AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V ... ... @@ -335,10 +335,8 @@ 335 335 ** DO1 is high in case there is load between DO1 and V+. 336 336 ** DO1 LED is off in both case 337 337 338 - 339 339 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 340 340 341 - 342 342 **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins. 343 343 344 344 ((( ... ... @@ -347,7 +347,6 @@ 347 347 348 348 [[image:image-20220523180452-3.png]] 349 349 350 - 351 351 ((( 352 352 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below 353 353 ))) ... ... @@ -363,8 +363,6 @@ 363 363 ))) 364 364 365 365 ((( 366 - 367 - 368 368 **To use counting mode, please run:** 369 369 ))) 370 370 ... ... @@ -383,8 +383,6 @@ 383 383 ))) 384 384 385 385 ((( 386 - 387 - 388 388 (% style="color:#4f81bd" %)**AT Commands for counting:** 389 389 ))) 390 390 ... ... @@ -481,9 +481,9 @@ 481 481 ))) 482 482 483 483 467 + 484 484 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 485 485 486 - 487 487 **LT22222-L**: This mode the DI1 is used as a counting pin. 488 488 489 489 The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour. ... ... @@ -490,7 +490,6 @@ 490 490 491 491 [[image:image-20220523181903-8.png]] 492 492 493 - 494 494 ((( 495 495 (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 496 496 ))) ... ... @@ -506,8 +506,6 @@ 506 506 ))) 507 507 508 508 ((( 509 - 510 - 511 511 **To use this mode, please run:** 512 512 ))) 513 513 ... ... @@ -534,8 +534,6 @@ 534 534 ))) 535 535 536 536 ((( 537 - 538 - 539 539 **Plus below command for AVI1 Counting:** 540 540 ))) 541 541 ... ... @@ -571,14 +571,11 @@ 571 571 572 572 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 573 573 574 - 575 575 **LT22222-L**: This mode the DI1 is used as a counting pin. 576 576 577 577 [[image:image-20220523182334-9.png]] 578 578 579 579 ((( 580 - 581 - 582 582 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 583 583 ))) 584 584 ... ... @@ -593,8 +593,6 @@ 593 593 ))) 594 594 595 595 ((( 596 - 597 - 598 598 **To use this mode, please run:** 599 599 ))) 600 600 ... ... @@ -614,6 +614,8 @@ 614 614 615 615 ((( 616 616 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 590 + 591 + 617 617 ))) 618 618 619 619 ... ... @@ -620,7 +620,6 @@ 620 620 621 621 === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === 622 622 623 - 624 624 (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.** 625 625 626 626 For example, if user has configured below commands: ... ... @@ -628,11 +628,13 @@ 628 628 * **AT+MOD=1 ** **~-~->** The normal working mode 629 629 * **AT+ADDMOD6=1** **~-~->** Enable trigger 630 630 605 + 631 631 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 632 632 633 633 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 634 634 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 635 635 611 + 636 636 **AT Command to set Trigger Condition**: 637 637 638 638 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -646,7 +646,6 @@ 646 646 AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 647 647 648 648 649 - 650 650 (% style="color:#4f81bd" %)**Trigger base on current**: 651 651 652 652 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> ... ... @@ -656,7 +656,6 @@ 656 656 AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) 657 657 658 658 659 - 660 660 (% style="color:#4f81bd" %)**Trigger base on DI status**: 661 661 662 662 DI status trigger Flag. ... ... @@ -663,13 +663,12 @@ 663 663 664 664 Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG > 665 665 666 - 667 667 **Example:** 668 668 669 669 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 670 670 671 671 672 -**Downlink Command to set Trigger Condition :**645 +**Downlink Command to set Trigger Condition** 673 673 674 674 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 675 675 ... ... @@ -698,7 +698,6 @@ 698 698 Same as AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 699 699 700 700 701 - 702 702 (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:** 703 703 704 704 MOD6 Payload : total 11 bytes payload ... ... @@ -712,6 +712,7 @@ 712 712 713 713 * Each bits shows if the corresponding trigger has been configured. 714 714 687 + 715 715 **Example:** 716 716 717 717 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -723,6 +723,7 @@ 723 723 724 724 * Each bits shows which status has been trigger on this uplink. 725 725 699 + 726 726 **Example:** 727 727 728 728 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. ... ... @@ -734,6 +734,7 @@ 734 734 735 735 * Each bits shows which status has been trigger on this uplink. 736 736 711 + 737 737 **Example:** 738 738 739 739 00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1. ... ... @@ -754,8 +754,6 @@ 754 754 === 3.3.7 Payload Decoder === 755 755 756 756 ((( 757 - 758 - 759 759 **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]] 760 760 761 761 ... ... @@ -775,6 +775,8 @@ 775 775 776 776 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 777 777 751 + 752 + 778 778 === 3.4.1 Common Commands === 779 779 780 780 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]