Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -19,6 +19,8 @@ 19 19 == 1.1 What is LT Series I/O Controller == 20 20 21 21 ((( 22 + 23 + 22 22 The Dragino (% style="color:blue" %)**LT series I/O Modules**(%%) are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (% style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %), **relay output**, **digital input**(%%) and (% style="color:blue" %)**digital output**(%%) etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring. 23 23 ))) 24 24 ... ... @@ -48,6 +48,7 @@ 48 48 49 49 ))) 50 50 53 + 51 51 == 1.2 Specifications == 52 52 53 53 ((( ... ... @@ -76,6 +76,8 @@ 76 76 ))) 77 77 78 78 ((( 82 + 83 + 79 79 **Interface for Model: LT22222-L:** 80 80 ))) 81 81 ... ... @@ -99,6 +99,8 @@ 99 99 ))) 100 100 101 101 ((( 107 + 108 + 102 102 **LoRa Spec:** 103 103 ))) 104 104 ... ... @@ -159,12 +159,11 @@ 159 159 * ((( 160 160 Packet engine up to 256 bytes with CRC. 161 161 169 + 170 + 162 162 163 163 ))) 164 164 165 - 166 - 167 - 168 168 == 1.3 Features == 169 169 170 170 * LoRaWAN Class A & Class C protocol ... ... @@ -177,7 +177,6 @@ 177 177 178 178 179 179 180 - 181 181 == 1.4 Applications == 182 182 183 183 * Smart Buildings & Home Automation ... ... @@ -189,7 +189,6 @@ 189 189 190 190 191 191 192 - 193 193 == 1.5 Hardware Variants == 194 194 195 195 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -204,7 +204,6 @@ 204 204 ))) 205 205 206 206 207 - 208 208 = 2. Power ON Device = 209 209 210 210 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -325,7 +325,6 @@ 325 325 * [1] RO1 relay channel is close and the RO1 LED is ON. 326 326 * [0] RO2 relay channel is open and RO2 LED is OFF; 327 327 328 - 329 329 **LT22222-L:** 330 330 331 331 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -379,12 +379,7 @@ 379 379 ((( 380 380 ((( 381 381 **AT+MOD=2** 382 -))) 383 -))) 384 384 385 -(% class="box infomessage" %) 386 -((( 387 -((( 388 388 **ATZ** 389 389 ))) 390 390 ))) ... ... @@ -403,40 +403,15 @@ 403 403 ((( 404 404 ((( 405 405 **AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 406 -))) 407 -))) 408 408 409 -(% class="box infomessage" %) 410 -((( 411 -((( 412 412 **AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 413 -))) 414 -))) 415 415 416 -(% class="box infomessage" %) 417 -((( 418 -((( 419 419 **AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 420 -))) 421 -))) 422 422 423 -(% class="box infomessage" %) 424 -((( 425 -((( 426 426 **AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 427 -))) 428 -))) 429 429 430 -(% class="box infomessage" %) 431 -((( 432 -((( 433 433 **AT+SETCNT=1,60 (Set COUNT1 value to 60)** 434 -))) 435 -))) 436 436 437 -(% class="box infomessage" %) 438 -((( 439 -((( 440 440 **AT+SETCNT=2,60 (Set COUNT2 value to 60)** 441 441 ))) 442 442 ))) ... ... @@ -471,12 +471,7 @@ 471 471 ((( 472 472 ((( 473 473 **AT+MOD=3** 474 -))) 475 -))) 476 476 477 -(% class="box infomessage" %) 478 -((( 479 -((( 480 480 **ATZ** 481 481 ))) 482 482 ))) ... ... @@ -483,11 +483,10 @@ 483 483 484 484 ((( 485 485 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 486 - 487 - 488 488 ))) 489 489 490 490 456 + 491 491 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 492 492 493 493 ... ... @@ -522,20 +522,13 @@ 522 522 ((( 523 523 ((( 524 524 **AT+MOD=4** 525 -))) 526 -))) 527 527 528 -(% class="box infomessage" %) 529 -((( 530 -((( 531 531 **ATZ** 532 532 ))) 533 533 ))) 534 534 535 -((( 536 - 537 -))) 538 538 497 + 539 539 ((( 540 540 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 541 541 ))) ... ... @@ -549,33 +549,17 @@ 549 549 (% class="box infomessage" %) 550 550 ((( 551 551 ((( 552 -**AT+SETCNT=3,60 (set AVI Count to 60)** 553 -))) 554 -))) 511 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 555 555 556 -(% class="box infomessage" %) 557 -((( 558 -((( 559 -**AT+VOLMAX=20000 (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 560 -))) 561 -))) 513 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 562 562 563 -(% class="box infomessage" %) 564 -((( 565 -((( 566 -**AT+VOLMAX=20000,0 (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 567 -))) 568 -))) 515 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 569 569 570 -(% class="box infomessage" %) 571 -((( 572 -((( 573 -**AT+VOLMAX=20000,1 (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 517 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 574 574 ))) 575 575 ))) 576 576 577 577 578 - 579 579 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 580 580 581 581 ... ... @@ -609,12 +609,7 @@ 609 609 ((( 610 610 ((( 611 611 **AT+MOD=5** 612 -))) 613 -))) 614 614 615 -(% class="box infomessage" %) 616 -((( 617 -((( 618 618 **ATZ** 619 619 ))) 620 620 ))) ... ... @@ -640,9 +640,8 @@ 640 640 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 641 641 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 642 642 581 +(% style="color:#037691" %)**AT Command to set Trigger Condition**: 643 643 644 -**AT Command to set Trigger Condition**: 645 - 646 646 (% style="color:#4f81bd" %)**Trigger base on voltage**: 647 647 648 648 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> ... ... @@ -677,7 +677,7 @@ 677 677 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 678 678 679 679 680 -**Downlink Command to set Trigger Condition:** 617 +(% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 681 681 682 682 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 683 683 ... ... @@ -720,7 +720,6 @@ 720 720 721 721 * Each bits shows if the corresponding trigger has been configured. 722 722 723 - 724 724 **Example:** 725 725 726 726 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -732,7 +732,6 @@ 732 732 733 733 * Each bits shows which status has been trigger on this uplink. 734 734 735 - 736 736 **Example:** 737 737 738 738 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. ... ... @@ -744,7 +744,6 @@ 744 744 745 745 * Each bits shows which status has been trigger on this uplink. 746 746 747 - 748 748 **Example:** 749 749 750 750 00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1. ... ... @@ -773,7 +773,6 @@ 773 773 ))) 774 774 775 775 776 - 777 777 == 3.4 Configure LT via AT or Downlink == 778 778 779 779 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands ... ... @@ -787,6 +787,7 @@ 787 787 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 788 788 789 789 723 + 790 790 === 3.4.1 Common Commands === 791 791 792 792 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -799,7 +799,7 @@ 799 799 800 800 Set device uplink interval. 801 801 802 -* AT Command: 736 +* (% style="color:#037691" %)**AT Command:** 803 803 804 804 (% class="box infomessage" %) 805 805 ((( ... ... @@ -809,7 +809,7 @@ 809 809 **Example: **AT+TDC=30000. Means set interval to 30 seconds 810 810 811 811 812 -* Downlink Payload (prefix 0x01): 746 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 813 813 814 814 (% class="box infomessage" %) 815 815 ((( ... ... @@ -822,7 +822,7 @@ 822 822 823 823 Set work mode. 824 824 825 -* AT Command: 759 +* (% style="color:#037691" %)**AT Command:** 826 826 827 827 (% class="box infomessage" %) 828 828 ((( ... ... @@ -832,7 +832,7 @@ 832 832 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 833 833 834 834 835 -* Downlink Payload (prefix 0x0A): 769 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 836 836 837 837 (% class="box infomessage" %) 838 838 ((( ... ... @@ -843,12 +843,12 @@ 843 843 844 844 ==== 3.4.2.3 Poll an uplink ==== 845 845 846 -* AT Command: 780 +* (% style="color:#037691" %)AT Command: 847 847 848 848 There is no AT Command to poll uplink 849 849 850 850 851 -* Downlink Payload (prefix 0x08): 785 +* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 852 852 853 853 (% class="box infomessage" %) 854 854 ((( ... ... @@ -863,7 +863,7 @@ 863 863 864 864 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 865 865 866 -* AT Command: 800 +* (% style="color:#037691" %)AT Command: 867 867 868 868 (% class="box infomessage" %) 869 869 ((( ... ... @@ -875,7 +875,7 @@ 875 875 0: Disable Trigger Mode 876 876 877 877 878 -* Downlink Payload (prefix 0x0A 06): 812 +* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 879 879 880 880 (% class="box infomessage" %) 881 881 ((( ... ... @@ -888,12 +888,12 @@ 888 888 889 889 Poll trigger settings, 890 890 891 -* AT Command: 825 +* (% style="color:#037691" %)AT Command: 892 892 893 893 There is no AT Command for this feature. 894 894 895 895 896 -* Downlink Payload (prefix 0x AB 06): 830 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 897 897 898 898 (% class="box infomessage" %) 899 899 ((( ... ... @@ -906,7 +906,7 @@ 906 906 907 907 Enable Disable DI1/DI2/DI2 as trigger, 908 908 909 -* AT Command: 843 +* (% style="color:#037691" %)AT Command: 910 910 911 911 (% class="box infomessage" %) 912 912 ((( ... ... @@ -918,7 +918,7 @@ 918 918 919 919 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 920 920 921 -* Downlink Payload (prefix 0xAA 02): 855 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 922 922 923 923 (% class="box infomessage" %) 924 924 ((( ... ... @@ -931,7 +931,7 @@ 931 931 932 932 Set DI1 or DI3(for LT-33222-L) trigger. 933 933 934 -* AT Command: 868 +* (% style="color:#037691" %)AT Command: 935 935 936 936 (% class="box infomessage" %) 937 937 ((( ... ... @@ -948,7 +948,7 @@ 948 948 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 949 949 950 950 951 -* Downlink Payload (prefix 0x09 01 ): 885 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ): 952 952 953 953 (% class="box infomessage" %) 954 954 ((( ... ... @@ -961,7 +961,7 @@ 961 961 962 962 Set DI2 trigger. 963 963 964 -* AT Command: 898 +* (% style="color:#037691" %)AT Command: 965 965 966 966 (% class="box infomessage" %) 967 967 ((( ... ... @@ -978,7 +978,7 @@ 978 978 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 979 979 980 980 981 -* Downlink Payload (prefix 0x09 02 ): 915 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 02 ): 982 982 983 983 (% class="box infomessage" %) 984 984 ((( ... ... @@ -991,7 +991,7 @@ 991 991 992 992 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 993 993 994 -* AT Command: 928 +* (% style="color:#037691" %)AT Command: 995 995 996 996 (% class="box infomessage" %) 997 997 ((( ... ... @@ -999,7 +999,7 @@ 999 999 ))) 1000 1000 1001 1001 1002 -* Downlink Payload (prefix 0xAA 01 ): 936 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 01 ): 1003 1003 1004 1004 (% class="box infomessage" %) 1005 1005 ((( ... ... @@ -1012,7 +1012,7 @@ 1012 1012 1013 1013 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1014 1014 1015 -* AT Command: 949 +* (% style="color:#037691" %)AT Command: 1016 1016 1017 1017 (% class="box infomessage" %) 1018 1018 ((( ... ... @@ -1020,7 +1020,7 @@ 1020 1020 ))) 1021 1021 1022 1022 1023 -* Downlink Payload (prefix 0xAA 00 ): 957 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 00 ): 1024 1024 1025 1025 (% class="box infomessage" %) 1026 1026 ((( ... ... @@ -1033,7 +1033,7 @@ 1033 1033 1034 1034 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 1035 1035 1036 -* AT Command: 970 +* (% style="color:#037691" %)AT Command: 1037 1037 1038 1038 (% class="box infomessage" %) 1039 1039 ((( ... ... @@ -1041,7 +1041,7 @@ 1041 1041 ))) 1042 1042 1043 1043 1044 -* Downlink Payload (prefix 0xAC ): 978 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAC ): 1045 1045 1046 1046 (% class="box infomessage" %) 1047 1047 ((( ... ... @@ -1052,12 +1052,12 @@ 1052 1052 1053 1053 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 1054 1054 1055 -* AT Command: 989 +* (% style="color:#037691" %)AT Command: 1056 1056 1057 1057 There is no AT Command to control Digital Output 1058 1058 1059 1059 1060 -* Downlink Payload (prefix 0x02): 994 +* (% style="color:#037691" %)Downlink Payload (prefix 0x02): 1061 1061 1062 1062 (% class="box infomessage" %) 1063 1063 ((( ... ... @@ -1086,12 +1086,12 @@ 1086 1086 1087 1087 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1088 1088 1089 -* AT Command: 1023 +* (% style="color:#037691" %)AT Command: 1090 1090 1091 1091 There is no AT Command to control Digital Output 1092 1092 1093 1093 1094 -* Downlink Payload (prefix 0xA9): 1028 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA9): 1095 1095 1096 1096 (% class="box infomessage" %) 1097 1097 ((( ... ... @@ -1155,12 +1155,12 @@ 1155 1155 1156 1156 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1157 1157 1158 -* AT Command: 1092 +* (% style="color:#037691" %)AT Command: 1159 1159 1160 1160 There is no AT Command to control Relay Output 1161 1161 1162 1162 1163 -* Downlink Payload (prefix 0x03): 1097 +* (% style="color:#037691" %)Downlink Payload (prefix 0x03): 1164 1164 1165 1165 (% class="box infomessage" %) 1166 1166 ((( ... ... @@ -1185,18 +1185,16 @@ 1185 1185 1186 1186 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1187 1187 1188 -* AT Command: 1122 +* (% style="color:#037691" %)AT Command: 1189 1189 1190 1190 There is no AT Command to control Relay Output 1191 1191 1192 1192 1193 -* Downlink Payload (prefix 0x05): 1127 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x05):** 1194 1194 1195 -(% class="box infomessage" %) 1196 -((( 1197 -**0x05 aa bb cc dd ~/~/ Set RO1/RO2 relay with time control:** 1198 -))) 1129 +**0x05 aa bb cc dd **~/~/ Set RO1/RO2 relay with time control 1199 1199 1131 + 1200 1200 This is to control the relay output time of relay. Include four bytes: 1201 1201 1202 1202 (% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05) ... ... @@ -1238,35 +1238,28 @@ 1238 1238 1239 1239 1240 1240 1173 + 1241 1241 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1242 1242 1243 1243 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1244 1244 1245 -* AT Command: 1178 +* (% style="color:#037691" %)**AT Command:** 1246 1246 1247 -(% class="box infomessage" %) 1248 -((( 1249 -**AT+VOLMAX ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]** 1250 -))) 1180 +(% style="color:#037691" %)****(%%)**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1251 1251 1252 1252 1253 -* Downlink Payload (prefix 0xA5): 1183 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** 1254 1254 1255 -(% class="box infomessage" %) 1256 -((( 1257 -**0xA5 aa bb cc ~/~/ Same as AT+VOLMAX=(aa bb),cc** 1258 -))) 1185 +**0xA5 aa bb cc **~/~/ Same as AT+VOLMAX=(aa bb),cc 1259 1259 1260 1260 1261 1261 1189 + 1262 1262 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1263 1263 1264 -* AT Command: 1192 +* (% style="color:#037691" %)**AT Command:** 1265 1265 1266 -(% class="box infomessage" %) 1267 -((( 1268 -**AT+SETCNT=aa,(bb cc dd ee) ** 1269 -))) 1194 +(% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) ** 1270 1270 1271 1271 aa: 1: Set count1, 1272 1272 ... ... @@ -1277,51 +1277,40 @@ 1277 1277 Bb cc dd ee: number to be set 1278 1278 1279 1279 1280 -* Downlink Payload (prefix 0xA8): 1205 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA8):** 1281 1281 1282 -(% class="box infomessage" %) 1283 -((( 1284 -**0x A8 aa bb cc dd ee ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)** 1285 -))) 1207 +**0x A8 aa bb cc dd ee **~/~/ same as AT+SETCNT=aa,(bb cc dd ee) 1286 1286 1287 1287 1288 1288 1211 + 1289 1289 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1290 1290 1291 1291 Clear counting for counting mode 1292 1292 1293 -* AT Command: 1216 +* (% style="color:#037691" %)**AT Command:** 1294 1294 1295 -(% class="box infomessage" %) 1296 -((( 1297 -**AT+CLRCOUNT ~/~/ clear all counting** 1298 -))) 1218 +(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1299 1299 1300 -* Downlink Payload (prefix 0xA6): 1301 1301 1302 -(% class="box infomessage" %) 1303 -((( 1304 -**0x A6 01 ~/~/ clear all counting,** 1305 -))) 1221 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** 1306 1306 1223 +**0x A6 01 ** ~/~/ clear all counting 1307 1307 1308 1308 1226 + 1227 + 1309 1309 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1310 1310 1311 -* AT Command: 1230 +* (% style="color:#037691" %)**AT Command:** 1312 1312 1313 -(% class="box infomessage" %) 1314 -((( 1315 -**AT+COUTIME=60 ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)** 1316 -))) 1232 +**AT+COUTIME=60 **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) 1317 1317 1318 -* Downlink Payload (prefix 0xA7): 1319 1319 1320 -(% class="box infomessage" %) 1321 -((( 1322 -**0x A7 aa bb cc ~/~/ same as AT+COUTIME =aa bb cc,** 1323 -))) 1235 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA7):** 1324 1324 1237 +**0x A7 aa bb cc **~/~/ same as AT+COUTIME =aa bb cc, 1238 + 1325 1325 ((( 1326 1326 range: aa bb cc:0 to 16777215, (unit:second) 1327 1327 ... ... @@ -1329,6 +1329,7 @@ 1329 1329 ))) 1330 1330 1331 1331 1246 + 1332 1332 == 3.5 Integrate with Mydevice == 1333 1333 1334 1334 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: ... ... @@ -2018,8 +2018,16 @@ 2018 2018 ))) 2019 2019 2020 2020 ((( 2021 - 1936 +== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? == 2022 2022 1938 +If the device is not shut down, but directly powered off. 1939 + 1940 +It will default that this is a power-off state. 1941 + 1942 +In modes 2 to 5, DO RO status and pulse count are saved in flash. 1943 + 1944 +After restart, the status before power failure will be read from flash. 1945 + 2023 2023 = 6. Trouble Shooting = 2024 2024 ))) 2025 2025