<
From version < 77.110 >
edited by Xiaoling
on 2022/06/10 09:36
To version < 77.111 >
edited by Xiaoling
on 2022/06/10 09:37
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -164,7 +164,6 @@
164 164  
165 165  
166 166  
167 -
168 168  == 1.3 Features ==
169 169  
170 170  * LoRaWAN Class A & Class C protocol
... ... @@ -177,7 +177,6 @@
177 177  
178 178  
179 179  
180 -
181 181  == 1.4  Applications ==
182 182  
183 183  * Smart Buildings & Home Automation
... ... @@ -189,7 +189,6 @@
189 189  
190 190  
191 191  
192 -
193 193  == 1.5 Hardware Variants ==
194 194  
195 195  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -204,7 +204,6 @@
204 204  )))
205 205  
206 206  
207 -
208 208  = 2. Power ON Device =
209 209  
210 210  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -286,7 +286,6 @@
286 286  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
287 287  
288 288  
289 -
290 290  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
291 291  
292 292  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -325,7 +325,6 @@
325 325  * [1] RO1 relay channel is close and the RO1 LED is ON.
326 326  * [0] RO2 relay channel is open and RO2 LED is OFF;
327 327  
328 -
329 329  **LT22222-L:**
330 330  
331 331  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -342,7 +342,6 @@
342 342  ** DO1 LED is off in both case
343 343  
344 344  
345 -
346 346  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
347 347  
348 348  
... ... @@ -640,7 +640,6 @@
640 640  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
641 641  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
642 642  
643 -
644 644  **AT Command to set Trigger Condition**:
645 645  
646 646  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -720,7 +720,6 @@
720 720  
721 721  * Each bits shows if the corresponding trigger has been configured.
722 722  
723 -
724 724  **Example:**
725 725  
726 726  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -732,7 +732,6 @@
732 732  
733 733  * Each bits shows which status has been trigger on this uplink.
734 734  
735 -
736 736  **Example:**
737 737  
738 738  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -744,7 +744,6 @@
744 744  
745 745  * Each bits shows which status has been trigger on this uplink.
746 746  
747 -
748 748  **Example:**
749 749  
750 750  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -786,7 +786,6 @@
786 786  
787 787  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
788 788  
789 -
790 790  === 3.4.1 Common Commands ===
791 791  
792 792  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0